CFD-2G

Amplifier-Discriminator

The CFD-2G is a hybrid amplifier-discriminator module designed for use with a wide variety of single photon detectors. It is neatly packaged to allow positioning close to the detector in order to minimise signal degradation, and features USB interface for simplified configuration.

Segment: Scientific
Produktionsfirma: HORIBA Scientific

Each module features:

  • Amplifier with bandwidth up to 2GHz
  • Constant fraction discriminator (CFD)
  • Simultaneous NIM and TTL-compatible outputs
  • Detector overload protection (operates in conjunction with HV supply)
  • USB and F-link PC interfaces (control panel software included)
  • Programmable non-volatile settings for gain, threshold, walk, and trip count rate (USB cable may be removed once module is configured)
  • Visual LED indication of activity
  • 15V power requirement

The CFD-2G's unique combination of features makes it particularly well suited to applications involving low gain detectors where immunity to interference and signal degradation is a critical consideration.  Its compact dimensions permit it to be close-coupled to MCP and NIR detection modules keeping the connection between the detector and the amplifier very short.  Furthermore, since the amplifier and discriminator are on the same board, direct conversion to digital (NIM and TTL) means there is no requirement to expose the analogue amplifier output to an external connector.

A detector overload feature allows the programming of a count rate monitor threshold that can be used to deactivate the detector's high voltage supply in order to protect the detector from damage due to over-illumination.  This feature operates in conjunction with the HORIBA Scientific Fluoro3PS HV power supply.

The CFD-2G is available in 4 variants optimised for different types of detector:

Table

Model

PMT type

Risetime

Transit Time Spread (TTS)

CFD-2G-A

MCP-PMT (e.g. R3809 series)

100ps

25ps

CFD-2G-B

Fast risetime PMT (e.g. H10330 series)

<1ns

<500ps

CFD-2G-C

Side-window type  PMT (e.g. R928)

<3ns

1ns

CFD-2G-D

Head-on type PMT (e.g. R5509)

Typically >3ns

1.5ns

Applications include:

  • Time-resolved fluorescence detection
  • Chemi-luminescence detection
  • Bioluminescence
  • Time-of-flight mass spectrometry
  • Single molecule detection
  • Photon correlation spectroscopy
  • LIDAR

Gain

20dB to 30dB programmable (40dB option available)

Threshold adjustment

-10mV to -200mV

Input connector

SMA type

Output connectors

Lemo00 (NIM, Camac)

NIM output

-0.8V peak at 5ns duration (50-Ohm termination)

TTL output

>2V peak at 5ns duration (50-Ohm termination)

Re-trigger rate50MHz

Indicators

Host, Limit, Count, Power

Power requirement

15V DC

Dimensions

13.5cm x 20cm x 3.9cm

Weight

0.47 kg

Specifications and appearance are subject to change without notice

CFD-2G example data

CFD-2G-A Example data - 34ps (FWHM) prompt with R3809 MCP-PMT and DeltaDiode laser.

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten. * Diese Felder sind Pflichtfelder.

Related products

More DAS6

Decay Analysis Software

More DeltaFlex

TCSPC Lifetime Fluorometer

More DeltaPro

TCSPC Lifetime Fluorometer

More DeltaTime

TCSPC Lifetime Kit

More Duetta

Fluorescence and Absorbance Spectrometer

More FluoroHub A+

TCSPC Lifetime Controller

More Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

More FluoroMax

Steady State and Lifetime Benchtop Spectrofluorometer

More Hybrid Picosecond Photon Detector (HPPD) Series

HORIBA’s latest development in TCSPC detector technology

More Microsense microliter fluorescence measurement solution

Easy to deposit, easy to recover, easy to clean.

More NanoLED

Pulsed Laser and LED Light Sources

More Nanosizer

For Single‐Walled Carbon Nanotube Excitation‐Emission Map Simulation and Analysis

More PPD Photon Counting Detector

Single photons detection with picosecond accuracy

More PrintQuest

Automated Fingerprint and Palmprint Identification - AFIS & APIS Systems

More PTI FelixGX

Steady State, Lifetime and Phosphorescence Software

More SpectraLED

LED Phosphorescence Light Sources

More Ultima

Ultra Fast TCSPC Lifetime Fluorometer

More Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

More Aqualog Datastream

For Instant Water Quality Reports

More DAS6

Decay Analysis Software

More DeltaDiode

Pulsed Laser and LED Light Sources

More DeltaFlex

TCSPC Lifetime Fluorometer

More DeltaPro

TCSPC Lifetime Fluorometer

More DeltaTime

TCSPC Lifetime Kit

More Duetta

Fluorescence and Absorbance Spectrometer

More FLIMera

Imaging camera for dynamic FLIM studies at real time video rates

More FluoroHub A+

TCSPC Lifetime Controller

More Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

More FluoroMax

Steady State and Lifetime Benchtop Spectrofluorometer

More Hybrid Picosecond Photon Detector (HPPD) Series

HORIBA’s latest development in TCSPC detector technology

More Microsense microliter fluorescence measurement solution

Easy to deposit, easy to recover, easy to clean.

More NanoLED

Pulsed Laser and LED Light Sources

More Nanolog

Steady State and Lifetime Nanotechnology EEM Spectrofluorometer

More Nanosizer

For Single‐Walled Carbon Nanotube Excitation‐Emission Map Simulation and Analysis

More PPD Photon Counting Detector

Single photons detection with picosecond accuracy

More PTI FelixGX

Steady State, Lifetime and Phosphorescence Software

More QuantaPhi-2

PLQY Integrating Sphere

More SpectraLED

LED Phosphorescence Light Sources

More Ultima

Ultra Fast TCSPC Lifetime Fluorometer

More Universal Fiber Coupling Solution

Connect any of our steady state and hybrid fluorometers to virtually any upright or inverted microscope!