Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

The HD-480 industrial dissolved oxygen meter takes sequential measurements of the concentration of dissolved oxygen, which is an indicator used in the management of activated sludge tanks in waste water processing, and the quality of the water in boilers, or rivers and waterways.
As there is no need to exchange the membrane of the disposable sensor included, it is easy for anyone to use.

Measuring range

Dissolived oxygen: 0 - 20 mg/L
Saturation: 0 - 200 %
Temperature: 0 - 40 ℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.
  • Exchanging the sensor is a one-touch operation
    The sensor is disposable, and can be exchanged with the touch of a key.
    There is no need for work requiring long experience or expertise, such as exchanging the membrane or refilling the internal fluid, as generally required by other sensors until now.
  • Two types of span correction
    You can choose from two types of span correction: the commonly used saturated fluid correction, and the plain and simple atmospheric correction.
  • Salt adjustment function
    A function which automatically corrects the data based on the salt concentration of the measurement sample has been included.
    This means it can make precise measurements in both freshwater and seawater.
  • Uses lead-free solder
    To reduce the burden on the environment, lead-free solder has been used to mount the components on the printed circuit board.

 

 

 Product name Dissolved oxygen meter
Model  HD-480
Measurement methodGalvanic cell method
Measuring range 
  • Dissolved oxygen 0 mg/L to 20 mg/L, 0.01 mg/L resolution
  • Saturation 0% to 200%, 1% resolution
  • Temperature 0℃ to 40℃, 0.1℃ resolution
 
RepeatabilityWithin ±0.5% of the full scale (by equivalent input)
LinearityWithin ±0.5% of the full scale (by equivalent input)
Transmission
output
 
  • 4 mA to 20 mA DC, input/output isolated type
  • Max. load resistance: 900 Ω
  • Transmission output range: Freely settable within the measuring range
 
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
 Contact type: relay contact, SPDT (1c)
 Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
 Contact function: Selectable from “Upper limit operation”, “lower limit operation”
   (ON/OFF control), “anomaly alarm”, “during maintenance”, and “temperature”
Calibration function 
  • Air calibration and solution calibration
  • Salinity compensation (0.0% to 5.0%)
  • Temperature calibration (two points)
 
Transmission output hold featureSelectable from previous value hold, optional value hold or continuous (however,only the previous value hold is available in the maintenance mode)
Self-diagnosis function 
  • Calibration failure: Zero error and sensitivity error
  • Sensor diagnosis: Short-circuit or disconnection of temperature sensor
  • Measuring range error
  • Product error
 
Temperature-compensated range0℃ to 40℃
Ambient temperature−5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage temperature−25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
  Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Compatible
standards
CE markingEMC :EN61326-1
    Class A, Industrial electromagnetic environment
Safety :EN61010-1
RoHS  :EN50581
    9. Industrial monitoring and control instruments
FCC rulesPart15 Class A
External dimensions48 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 400 g
Compatible sensorsProbeDP-100Operating temperature: 0℃ to 45℃

Sensor

5400, 5405

 

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

Aqualog - Water Treatment Plant Analyzer
More Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

EMGA-920
More EMGA-920

Oxygen/Nitrogen Analyzer

EMGA-921
More EMGA-921

Hydrogen Analyzer

EMGA-930
More EMGA-930

Oxygen/Nitrogen/Hydrogen Analyzer

HC-200F
More HC-200F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
More HC-200NH

Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)

HC-300F
More HC-300F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200FL
More HD-200FL

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HD-960LR
More HD-960LR

Dissolved oxygen concentration monitor series for semiconductor manufacturing

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
More HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HD-960LR
More HD-960LR

Dissolved oxygen concentration monitor series for semiconductor manufacturing

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
More HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960CW
More HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
More HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
More HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
More HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW
More HE-960RW

Panel-mount Type Resistivity Meter(Four-Wire Transmission, 2-channel)

HE-960RW-GC(W)
More HE-960RW-GC(W)

2-Channel Resistivity Meter

HE-960TM
More HE-960TM

TMAH Conductivity Meter. Perfect for Controlling TMAH Developer Concentrations

HF-960H
More HF-960H

HF / HCl Concentration Monitor

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
More HF-SP-CU

2-channel High Precision HF Concentration Monitor

HO-200
More HO-200

Field-installation Type ORP Meter (Four-Wire Transmission)

HO-300
More HO-300

Field-installation Type ORP Meter (Two-Wire Transmission)

HO-480
More HO-480

Panel-mount Type ORP Meter (Four-Wire Transmission)

HR-200
More HR-200

Feild-installation Type Residual Chlorine Meter (Four-Wire Transmission, Water flow beads)

HR-200RT
More HR-200RT

Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)

HR-480
More HR-480

Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission)