IT-470F-H

High-Accuracy Infrared Thermometer [Built-in type]

Industry Leading* High Accuracy Thermometer

The IT-470F-H is a built-in type, non-contact infrared thermometer with industry-leading* accuracy. It contributes to improve process stabilization, for which requires high accuracy temperature measurement, such as semiconductor and FPD production.

 

*Resuts of 2024 in-house study

 

  • Absolute high measurement accuracy ±0.1°C* and superior repeatability(2σ) of 0.1°C*.

*Actual value, under given conditions.

Application

For semiconductor and FPD production which requires high accuracy temperature measurement

  • In case of a susceptor is in a vacuum chamber
    Temperature measurement of a susceptor is possible from outside of a chamber through the window
  • In case of surface temperature measurement of liquid crystal substrate in FPD production process.
    As non contact measurement, surface is not damaged.
  • In case of temperature controlling in polishing
    As non contact measurement, surface is not damaged.

 

 

Measurement wavelength8 to 14µm
Measurement temp. range-50 to 200℃
Output resolutionOptical digital output: 0.1℃    Current output ≤0.025%FS
Accuracy*
(Optical digital output)
±4.0℃ (Object temperature -50℃)
±0.8℃ (Object temperature -20℃)
±0.6℃ (Object temperature 0℃)
±0.5℃ (Object temperature 23℃)
±0.4℃ (Object temperature 100℃〜)
(Linear interpolation is applied for the mid-points of object temperature and interpolated data are rounded to one decimal place.)
Repeatability
(Optical digital output)
0.7℃ (Object temperature -50℃)
0.5℃ (Object temperature 23℃)
0.5℃ (Object temperature 200℃)
(In case of the emissivity = 1.000 and use the 2σ value of 10 times measurement)
Response time (Optical digital output)Optical digital output: ≤1.4 sec (running average 1 sec, at 95% response)
Data sampling period0.1 sec
Display update periodOptical digital output: 0.2 sec  Current output: 0.1 sec
Measuring diameterΦ8mm/Distance 150mm (incident light amount 90%)
Emissivity setting0.001 to 1.000 changeable (Setting at factory shipping)
Operating temp. & humidity0 to 55℃, 35〜85%RH (no condensation)
PowerDC24V±5%
FunctionOptical digital output (JIS F05)    Current output 4 to 20mA (Load resistance 100Ω, non-isolated)
Dimensions55×44×96mm Power, Current cable attached (Standard length 2m)
Mass≤300g

*Condition: Operating temperature 24 to 29℃ (include temperature of attachment), Humidity 55±20%, Emissivity correction setting 1.000.

Solicitud de Información

Tiene alguna pregunta o solicitud? Utilice este formulario para ponerse en contacto con nuestros especialistas.

* Estos campos son obligatorios.

Related products

IT-545 Series
IT-545 Series

High-Accuracy Infrared Thermometers [Handheld type]

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

IT-480 series
IT-480 series

High-Accuracy Infrared Thermometers [Stationary type]

IT-545 Series
IT-545 Series

High-Accuracy Infrared Thermometers [Handheld type]

Corporate