HE-480H

Panel-mount type conductivity meter (conductivity meter)

For monitoring wastewater treatment, seawater, and hydroponic nutrient solutions.

Actively monitors wastewater treatment, seawater, and hydroponic nutrient solutions. A lineup of sensors that are suitable for various sample characteristics are offered. The use of panel-mounted transmitters allows for cost savings at the time of installation.

COND

Division: Process Water
Fabricant: HORIBA Advanced Techno Co., Ltd.

A lineup of sensors that are tailored to specific applications

A lead type sensors, which can be directly thrown into the tank or placed in the tank with an immersion holder, are available.

Possible to be used in a panel-mounted configuration

This transmitter is easy to install while providing standard functions.

Salinity concentration conversion function

The transmitter is equipped with a salinity concentration conversion function that is suitable for monitoring the salinity of seawater.

Product nameIndustrial conductivity meter
ModelHE-480H
Measurement
method
Electrode type (4-electrode method)
Cell constant1.0/cm
Measuring range*Measurement range
(S/m)
0.000 to 2.0000.00 to 20.000.00 to 50.00
Measurement range
(mS/cm)
0.00 to 20.000.0 to 200.00.0 to 500.0
Seawater salinity
conversion value (%)
0.00 to 4.00
NaCl salinity
conversion value (%)
0.0 to 20.0
Temperature0℃ to 100℃
(The displayed decimal place is selectable among 0, 1, and 2.)
RepeatabilityConductivity displayWithin ±0.5% of the full scale(in equivalent input)
Salinity conversion displayWithin ±1% of the full scale
LinearityConductivity displayWithin ±0.5% of the full scale(in equivalent input)
Salinity conversion displayWithin ±1% of the full scale
Transmission
output
4 mA to 20 mA DC: input/output isolated type
Maximum load resistance: 900Ω
Transmission output range: Freely selectable within the measurement range
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
 Contact type: relay contact, SPDT (1c)
 Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
 Contact function: selectable from upper/lower limit operation (ON/OFF control), alarm, and maintenance.
Calibration functionConductivity: Based on the specified compensation coefficient for the cell constant
(parameter input)
Temperature: Calibrated by comparing with the reference thermometer
Transmission
output hold feature
  • Previous value hold
  • Optional value hold
  • Continuous
    Selectable from the above (However, only the previous value hold is available in the maintenance mode.)
Self-diagnosis
function
  • Sensor diagnosis
    Short-circuit and disconnection of the temperature sensor
  • Out of the measurement range
  • A/D converter scale over
  • Converter error
Temperature
compensation
  • Temperature characteristics of NaCl
  • Freely selectable reference temperature and temperature coefficient
Measurement rangeReference
temperature
Temperature
coefficient
0.000 S/m to 2.000 S/m
(0.00 mS/cm to 20.00 mS/cm)
5℃ to 95℃±5%/℃
0.00 S/m to 20.00 S/m
(0.0 mS/cm to 200.0 mS/cm)
25℃±3.5%/℃
0.00 S/m to 50.00 S/m
(0.0 mS/cm to 500.0 mS/cm)
No temperature compensation
  • No temperature compensation
Temperature compensated range0℃ to 100℃
Ambient
temperature
-5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
-25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directive: EN61326-1
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
FCC RuleFCC Part15
External
dimensions
48 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 400 g
Compatible sensorsFES series conductivity sensor, cell constant 100/m (1.0/cm)
(The measurement range differs depending on the sensor model.)

* Sensors and measurement ranges

 

Sensor modelFES-125
FES-125F
FES-126
FES-126F
FES-105
FES-105F
FES-116
FES-116F
Measurement
range
0.000 S/m to 2.000 S/m
(0.00 mS/cm to 20.00 mS/cm)
0.00 S/m to 20.00 S/m
(0.0 mS/cm to 200.0 mS/cm)
 
0.00 S/m to 50.00 S/m
(0.0 mS/cm to 500.0 mS/cm)
 
Seawater
salinity
conversion
value
0.00% to 4.00%
NaCl salinity
conversion
value
0.0% to 20.0% 
Temperature0℃ to 50℃
0℃ to 100℃  

✔ Applicable

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

9371-10D Conductivity Cell
9371-10D Conductivity Cell

Conductivity Cell for Ultra Pure Water Measurement

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

H-1 Series
H-1 Series

Field-installation type water quality measuring instruments

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HF-700A
HF-700A

Low Concentration Monitor- Sulfuric Acid/Hydrogen Peroxide

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HO-480
HO-480

Panel-mount type ORP meter

HR-200
HR-200

Field-installation type polarographic residual chlorine meter

HR-200RT
HR-200RT

Field-installation type residual chlorine meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter