PTFM-ONE-DT

Dual Pitot Tube Exhaust Flow Meter

The Dual Pitot Tube Flow Meter, PTFM-ONE DT is a standalone interface for measuring exhaust gas flow rate of combustion engines. The system uses the tried-and-tested pitot tube principle with high-frequency transducers, with a sampling rate of 1kHz to accurately measure highly pulsating exhaust flows. This rapid capture rate ensures that any pulsations or exotic behaviour caused by the engine is measured, and the unique design of the PTFM-ONE DT means reverse flows can be calculated, with the same guarantee of sensitivity.

The interface can run standalone with a laptop, or seamlessly integrated to run alongside a Test Automation System.

900Β°C Exhaust Gas LimitAllows the freedom to test engines under extreme conditions without worrying if the
flow meter can handle those temperatures
-1.25kPa to +7.5kPa
Sensor Range
Shows both positive flow & negative flow in the tailpipe. Also, HORIBA capped the
positive pressure at +7.5kPa to ensure we cause as little backpressure on your
engine as possible
Dual Tube SystemThis is the patented setup of 2 pitot tubes and a valve to switch automatically to
keep the system measuring with it best possible accuracy range. It uses the
smaller tube for flows below 4.5 m3/min and both tubes if flows peak above the
smaller tubes flow limit up to 14.5m3/min.
1Khz High Speed TransducersHaving fast sampling of the pressure changes in the tailpipe allow for a rapid visual
representation of the spikes and negative pulses that happen with a combustion
engine. Lower speed sampling would miss these spikes and negatives giving you
an inaccurate representation of what is happening inside the tailpipe.
Temperature CompensationThe PTFM-ONE automatically compensates to 20Β°C when testing so there is no
need to warm up.
Multiple Communication
Options
The PTFM-ONE has 2 connection options. LAN for AK connections to Automation
systems or the PTFM Host programme & Analogue out (0-10V with 4 configurable
channels available)
2 Options of
Absolute Pressure Sensors
The PTFM-ONE can be purchased in 2 absolute pressure ranges supporting testing
from sea level to a) 2100m or b) 4500m.
System Configuration
(Standard unit)
  • Dual Pitot Tube Setup (1 for low end & 1 for high end)
  • System Controller
Tube Diameter & Measuring Range

The System comes with a B & C Tube in parallel with each other and a valve in between.

  • B-type: f42.7 / f39.7 mm (0.15 m3/min to 4.5 m3/min)
  • C-type: f60.5 / f56.5 mm (0.3 m3/min to 10 m3/min)

Both B and C Tubes work in parallel with each other, providing a Max Flow of 14.5 m3/min.

Linearity

Either of the following:

  • Within Β±2.0 % of full scale
  • Intercept: |a0| ≀ 1.0 % of full scale
    Slope: 0.98 ≀ a1 ≀ 1.02
    Standard estimated error: SEE ≀ 2.0% of full scale
    Coefficient of determination: r2 β‰₯ 0.990
Flow Rate AccuracyWithin Β±1 % of full scale or within Β±1.5 % of readings (whichever larger) (at flow rate of 20 % of full scale)
Exhaust Pressure Sensor Range-1.25 – 7.5 kPa
Atmospheric Pressure Sensor Range
  • Standard configuration: 80 to 110 kPa
  • Optional configuration: 60 to 110 kPa
Environment for use
  • Temperature: -20ΒΊC to +40ΒΊC
  • Humidity: Under 80% as relative humidity
  • Altitude: 0m to 2100m above sea level *option for up-to 4500m
Approved StandardsCE, FCC, RoHS compliant
Dimensions923 x 480 x 1204 H x W x D (mm)
Mass115KG Approx.

 

μ œν’ˆ 문의

HORIBAμ œν’ˆμ˜ μžμ„Έν•œ 정보λ₯Ό μ›ν•˜μ‹œλ©΄, μ•„λž˜μ˜ 양식에 λ‚΄μš©μ„ μž…λ ₯을 λΆ€νƒλ“œλ¦½λ‹ˆλ‹€.

* λŠ” ν•„μˆ˜μž…λ ₯ν•­λͺ©μž…λ‹ˆλ‹€.

Related products

CVS-ONE
CVS-ONE

희석 λ°°κΈ°κ°€μŠ€ 뢄석기

EXFM-ONE
EXFM-ONE

초음파 λ°°κΈ° μœ λŸ‰κ³„

FTX-ONE-CL
FTX-ONE-CL

FTIR λ°°κΈ° κ°€μŠ€ 뢄석기 희석 μΈ‘μ • νƒ€μž…

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR λ°°κΈ°κ°€μŠ€ 뢄석 μΈ‘μ • μ‹œμŠ€ν…œ (직접 μΈ‘μ • 방식)

MDLT-ONE
MDLT-ONE

λΆ€λΆ„ 희석 PM μƒ˜ν”Œ μž₯치

MEXA-2000SPCS series
MEXA-2000SPCS series

λ°°κΈ°κ°€μŠ€ 고체 μž…μž μΉ΄μš΄νŒ… μ‹œμŠ€ν…œ

MEXA-ONE
MEXA-ONE

λ°°κΈ° κ°€μŠ€ μΈ‘μ • μž₯치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

λ ˆμ΄μ € λΆ„κ΄‘ λ°°κΈ°κ°€μŠ€ μΈ‘μ • μž₯치

OBS-ONE GS Unit
OBS-ONE GS Unit

μ°¨λŸ‰ νƒ‘μž¬ν˜• λ°°κΈ°κ°€μŠ€ μΈ‘μ • μž₯치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O λŒ€μ‘μš© μ°¨λŸ‰ νƒ‘μž¬ν˜• λ°°κΈ°κ°€μŠ€ μΈ‘μ • μž₯치

OBS-ONE PM unit
OBS-ONE PM unit

μ°¨λŸ‰ νƒ‘μž¬ν˜• λ°°κΈ°κ°€μŠ€ μΈ‘μ • μž₯치

OBS-ONE PN Unit
OBS-ONE PN Unit

μ°¨λŸ‰ νƒ‘μž¬ν˜• λ°°κΈ°κ°€μŠ€ μΈ‘μ • μž₯치

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

SPN10 λΆ„μ„μš© μ°¨λŸ‰ νƒ‘μž¬ν˜• λ°°κΈ°κ°€μŠ€ μΈ‘μ • μž₯치

CRITERION D500
CRITERION D500

Pressure Insensitive Mass Flow Module

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

CVS-ONE
CVS-ONE

희석 λ°°κΈ°κ°€μŠ€ 뢄석기

D700MG
D700MG

High Speed & Precision Pressure Insensitive Mass Flow Module

D700WR
D700WR

Wide Range Pressure Insensitive Mass Flow Module

DZ-100
DZ-100

Ultra-thin Mass Flow Controller

EXFM-ONE
EXFM-ONE

초음파 λ°°κΈ° μœ λŸ‰κ³„

FS-3000
FS-3000

Thermal Flow Splitter

HC-200F
HC-200F

ν˜„μž₯μ„€μΉ˜ν˜• λΆˆμ†Œμ΄μ˜¨μΈ‘μ •κΈ°(4-Wire Transmission)

HC-300F
HC-300F

ν˜„μž₯μ„€μΉ˜ν˜• λΆˆμ†Œμ΄μ˜¨μΈ‘μ •κΈ°(2-Wire Transmission)

HD-200
HD-200

ν˜„μž₯μ„€μΉ˜ν˜• μš©μ‘΄μ‚°μ†ŒμΈ‘μ •κΈ°(4-Wire Transmission), λ©€λΈŒλ ˆμΈν˜•)

HD-200FL (Four-Wire Transmission, 광학식)
HD-200FL (Four-Wire Transmission, 광학식)

ν˜„μž₯ μ„€μΉ˜ν˜• 용쑴 μ‚°μ†Œ μΈ‘μ •κΈ°

HD-300
HD-300

ν˜„μž₯μ„€μΉ˜ν˜• μš©μ‘΄μ‚°μ†ŒμΈ‘μ •κΈ°(2-Wire Transmission), 멀브레인 ν˜•)

HD-480
HD-480

μš©μ‘΄μ‚°μ†ŒμΈ‘μ •κΈ°(4-Wire Transmission), 멀브레인 ν˜•)

HD-960L
HD-960L

저농도 용쑴 μ‚°μ†Œ λͺ¨λ‹ˆν„°

HD-960LR
HD-960LR

용쑴 μ‚°μ†Œ 농도 λͺ¨λ‹ˆν„°

HE-200C
HE-200C

ν˜„μž₯μ„€μΉ˜ν˜• 전기전도도계(4-Wire Transmission, μ €λ†λ„μš©)

HE-200H
HE-200H

ν˜„μž₯μ„€μΉ˜ν˜• 전기전도도계(4-Wire Transmission, κ³ λ†λ„μš©)

HE-200R
HE-200R

ν˜„μž₯ μ„€μΉ˜ν˜• 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

ν˜„μž₯ μ„€μΉ˜ν˜• 전기전도도계 (2-Wire Transmission, μ €λ†λ„μš©)

HE-300C-IS ( λ°©ν­ν˜• )
HE-300C-IS ( λ°©ν­ν˜• )

λ°©ν­ν˜• μ„€μΉ˜ νƒ€μž… COND meter ( Low concentrtion )

HE-300R
HE-300R

ν˜„μž₯ μ„€μΉ˜ν˜• 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

νŒ¨λ„ μž₯μ°©ν˜• 전도도계(4-Wire Transmission, μ €λ†λ„μš©)

HE-480C-GC
HE-480C-GC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (μ €λ†λ„ν˜•)

HE-480H
HE-480H

νŒ¨λ„ μž₯μ°©ν˜• 전도도계(4-Wire Transmission,μ €λ†λ„μš©)

HE-480H-DC24V
HE-480H-DC24V

νŒλ„¬ μž₯μ°©ν˜• 전도도계(4-wire Transmitter , κ³ μ „λ„λ„μš©)

HE-480R
HE-480R

νŒ¨λ„ μž₯μ°©ν˜• 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

ꡬ연산 λͺ¨λ‹ˆν„°

HE-960CW
HE-960CW

νŒ¨λ„ μž₯μ°©ν˜• 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH λͺ¨λ‹ˆν„°

HE-960H-TM-S
HE-960H-TM-S

κ³ μ •λ°€ TMAH 농도 λͺ¨λ‹ˆν„°

HE-960HC
HE-960HC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (κ³ λ†λ„ν˜•)

HE-960HI
HE-960HI

νŒ¨λ„ μž₯μ°©ν˜• 전도도계(4-Wire Transmission, κ΄‘μ—­μš©)

HE-960LC
HE-960LC

μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960RW
HE-960RW

νŒ¨λ„ μž₯μ°©ν˜• 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 μ €ν•­λ₯ κ³„

High Temperature Digital Mass Flow Controller SEC-8000F/D series
High Temperature Digital Mass Flow Controller SEC-8000F/D series

High Temperature Digital Mass Flow Controller

HO-480
HO-480

νŒ¨λ„ μž₯μ°©ν˜• ORP λ―Έν„° (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ν˜„μž₯ μ„€μΉ˜ν˜• pH Meter

HP-300
HP-300

ν˜„μž₯ μ„€μΉ˜ν˜• pHλ―Έν„° (2-Wire Transmission)

HP-480
HP-480

νŒ¨λ„ μž₯μ°©ν˜• pHλ―Έν„° (4-Wire Transmission)

HP-480PL
HP-480PL

νŒ¨λ„ μž₯μ°©ν˜• pH λ―Έν„°(4-Wire Transmission, νŽ„μŠ€ λΉ„λ‘€ μ œμ–΄)

HP-480TP
HP-480TP

νŒ¨λ„ μž₯μ°©ν˜• pH λ―Έν„°(4-Wire Transmission, μ‚°μ—…μš© μ‹œλΆ„ν•  λΉ„λ‘€μ œμ–΄)

HP-960FTP
HP-960FTP

νŒ¨λ„ μž₯μ°©ν˜• pH λ―Έν„°(4-Wire Transmission, 4 포인트 μ•ŒλžŒ, μ‹œλΆ„ν•  λΉ„λ‘€ μ œμ–΄)

HR-200
HR-200

ν˜„μž₯ μ„€μΉ˜ν˜• μž”λ₯˜μ—Όμ†Œ μΈ‘μ •κΈ° (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

ν˜„μž₯ μ„€μΉ˜ν˜• μž”λ₯˜ μ—Όμ†Œ μΈ‘μ •κΈ° (4-Wire Transmission, Rotating Type)

HR-480
HR-480

μž”λ₯˜ μ—Όμ†Œ μΈ‘μ •κΈ° (4-Wire Transmission)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

LE Series
LE Series

Large Flow Liquid Source Vaporization Control System

MV-2000
MV-2000

Mixed Injection System Liquid Vaporizer

Corporate