Partica CENTRIFUGE*

원심 나노 입자 분석기

원심분리에 의한 고해상도 입자 크기 분포 측정.
측정 범위가 10 nm - 40 μm인 Partica CENTRIFUGE는 최대 30,000g의 원심력을 적용하고 온도 제어를 사용하여 다양한 샘플에 대한 정확한 측정 결과를 생성합니다.
고객 피드백을 기반으로 개발되고 기존 및 새로운 HORIBA 기술을 개선한 결과, 사용하기 편리하면서도 안전하고 안정적인 작동을 제공하는 분석기가 탄생했습니다.

*중국, 인도, 일본, 한국, ASEAN 및 기타 일부 국가에서 사용 가능합니다.

Segment: Scientific
Manufacturing Company: HORIBA, Ltd.

Realizing precision particle size distribution measurement for undiluted to dilute samples
The key features of centrifugation is that the particle size is measured following classifying by size. As a result, a wide range of high-precision results can be obtained in a single analysis. Partica CENTRIFUGE enables you to measure by two measurement techniques: The “Line-start mode” and the “Homogeneous mode”.

Small amounts of foreign particle or agglomeration can be captured
With its high resolution, Partica CENTRIFUGE can capture a small amount of foreign particles. This instrument enables you to obtain reliable measurement results throughout the range of the particle size distribution, including small populations, as well as to the low area of the distribution.

Features stable measurement even for the long time measurements
The cooling function of the sample chamber and the rotor prevents temperature increases of sample fraction during rotation. This improves the reliability of the measurement results by keeping the viscosity constant. Partica CENTRIFUGE is designed for quieter, easier, safer operation.

Robust and easy to use

•Easy and safe operation by simply setting a cell filled with sample on a rotor.

•The cuvette-type cell is easy to clean and replace, reducing the risk of contamination.

•Complies with international safety standards (IEC6101-1/2-020)


Measurement Examples

High resolution particle size distribution measurement

As a result of measuring a mixed sample containing four types in equal concentrations of, standard silica particles, four types of distributions were obtained with almost the same area. Using the line-start mode measurement, an accurate particle size distribution is obtained because the particles are classified by the centrifugal force.

Sample:  Standard particles (One drop each of particles with sizes of 0.48 μm,
     0.73 μm, 0.99 μm, and 1.57 μm are mixed)
Amount of sample:  10 μL
Solvent:  Aqueous sucrose solution
Measurement condition:  Line-start mode


Measurement of the particle size distribution of a small quantity, high concentration sample

Example of black pigment used for inkjet printers starting with an undiluted solution. As a result, the particle size distribution of a high concentration sample, which is difficult to measure is shown, with high precision from a small 2 μL sample

Sample:  Black pigment for inkjet printers (undiluted solution)
Amount of sample:  2 μL
Solvent:  Aqueous sucrose solution
Measurement condition:  Line-start mode

Model name: CN-300

Measurement method

Centrifugation using a cuvette cell: Both the line-start mode and the homogeneous mode

Measurement range

10 nm - 40 μm

Max. centrifugal force

30,000 G

Temperature control

The rotor, cell, and sample temperatures are controlled to a fixed temperature by the refrigeration.

Working temperature

15 - 25℃

Dimensions

634 (W)× 550 (D) × 341 (H) mm

Mass

100 kg

Option

Density gradient fractionator (CY-301)


Dimensions

[Option] Density gradient fractionator (CY-301)

A fractionator is available to facilitate the preparation of density gradient solutions required for line-start measurements. By placing the cuvette cell and pressing a button, the density gradient solution can be prepared in about 3 minutes.

Evaluation of Diameter (Thickness) and Aggregation/Dissociation State of Carbon Nanotube Dispersions
Evaluation of Diameter (Thickness) and Aggregation/Dissociation State of Carbon Nanotube Dispersions
Carbon nanotubes (CNTs) are thin, light, and flexible string-like materials that are composed entirely of carbon atoms. CNTs easily aggregate, so it is essential to understand and control the state of aggregation in order to achieve the expected performance. For this purpose, an analytical method that can quickly evaluate wide particle size distributions (PSD) from isolated dispersion to aggregation, with high resolution, is necessary.
Measurement of Particle Size Distribution of Nanocellulose using Centrifugal Sedimentation Method
Measurement of Particle Size Distribution of Nanocellulose using Centrifugal Sedimentation Method
Nanocellulose is a fibrous material derived from wood that is applied to composite materials and is attracting attention as an advanced material. In order to utilize nanocellulose, it is important to understand the fiber diameter and dispersion state. 3 types of nanocellulose were analyzed using the Partica CENTRIFUGE centrifugal nanoparticle analyzer.
Analysis to Separate Mixed Samples of the Same Size but Different Materials
Analysis to Separate Mixed Samples of the Same Size but Different Materials
In general particle size analyzers, particles of the same size are measured as the same size regardless of material, making it difficult to separate particles of different materials when they are mixed together. The centrifugal sedimentation particle size analyzer measures the sedimentation speed and converts it into a particle size value using the density information of the particles. Therefore, particles of the same size but different densities will have different settling speed and can be measured separately.
Analysis of the Mixed State of Slurry Battery Materials
Analysis of the Mixed State of Slurry Battery Materials
We analyzed two slurry battery materials containing active material (NCM) and conductive agent (carbon). By using Partica CENTRIFUGE to analyze battery materials before and after kneading, results with distinctly different distributions were obtained, which enable us to infer the dispersion state of the battery materials.
High Repeatability Particle Size Distribution Measurement of Colloidal Silica for CMP slurries
High Repeatability Particle Size Distribution Measurement of Colloidal Silica for CMP slurries
CMP technology is essential in the manufacturing process of large scale semiconductor integrated circuits (LSI). Colloidal silica are widely used as CMP slurries because of their clean spherical shape. Colloidal silica was measured by Partica CENTRIFUGE and its measurement repeatability was confirmed.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

Partica CENTRIFUGE*
Partica CENTRIFUGE*

원심 나노 입자 분석기

nanoPartica SZ-100V2 Series
nanoPartica SZ-100V2 Series

나노입자 분석기

Partica CENTRIFUGE*
Partica CENTRIFUGE*

원심 나노 입자 분석기

Partica LA-960V2
Partica LA-960V2

레이저 산란 입자 크기 분포 분석기

Partica mini LA-350
Partica mini LA-350

레이저 회절 입도 분포 분석기

SZ-100 시리즈
SZ-100 시리즈

나노 입자 분석기

ViewSizer 3000
ViewSizer 3000

멀티 레이저 나노 입자 추적 분석기