SLFA-60

X선 형광 유황 분석기

이동식 유황 분석기의 새로운 표준인 SLFA-60은 석유 산업의 성장 속도에 발맞춰 새로운 소프트웨어 및 하드웨어 기능을 업데이트하여 출시 되었습니다. 새로운 SLFA series는 교정 곡선을 전 모델보다 더 많이 생성할 수 있으며,  USB 출력을 사용하여 데이터를 내보낼 수 있습니다. 측정 범위는 고유황 원유 및 셰일 오일 시장의 대응을 위해 0-9.9999wt%로 넓어 졌습니다.

특징

  • 간단한 조작
  • 간편한 유지 보수
  • 가벼운 무게
  • 컴팩트한 사이즈
  • 견고한 구조
Segment: Scientific
Manufacturing Company: HORIBA, Ltd.
  •  Measurement Procedure:

     • Pour the sample into the sample cell.
     • Place the sample cell on the sample holder
     • Set to the measurement condition
     • Press the "MEAS" button to start the measurement
     • Instrument displays the results and data output

  • Calibration
    New software features allow up to 15 separate calibration curves. There are three sets and each set represents 5 separate calibration curves. The software also allows the users to choose between linear or quadratic curves. Calibration curves are restored manually without having to recalibrate as long as coefficients value/calibration data are on hand.

  • Original Sample Cell
    To ensure accuracy and reliability of the analysis, HORIBA has maintained its original sample cell. By using the sample jig tool provided, you can easily seal the sample so that it is leak free.

  • Expanded Measurement Range (0~9.9999wt%)
    This new model can measure a wider range of sulfur content. It has an expanded range to measure from 0-9.9999 wt% sulfur, due to the higher sulfur concentrations of crude and shale oil markets.

  • Large printouts
    Printouts show important information, including sample ID, X-ray spectrum, date and time, measurement average value, standard deviation and calibration curve graph.

  • Data output
    The printout is available in an 80 mm wide format for easy comprehension.

  • Safety mechanism
    The SLFA-60 has a protective membrane covering the cell window to prevent the detector and X-ray tube from accidental sample leakage. This protective membrane unit is simple to assemble and replace.

  • Large screen display for easy viewing
    The screen will display real-time data to check the measurement conditions.

  • USB memory
    Your measurements can be recorded three different ways; by printout, exported to a USB memory device, or exported to an external PC through a USB interface, making it possible track and analyze the information throughout the lifetime of the unit.

Measurement PrincipleEnergy Dispersive X-ray Fluorescence Analysis Method (EDXRF)
Measurement SampleSulfur in Petroleum products such as heavy oil, naphtha, and crude oil, light oil
Measurement Range0 - 9.9999 %
Repeatability15 ppm or less (with a 1 % sulfur sample)
C/H Error Correction± 50 ppm or less per C/H (with a 1 % sulfur sample)
Lower Detection Limit20 ppm or less (three times the standard deviation with a 0 % sample)
Number of Calibration Curves5 lines × 3 sets (Total 15 lines)
Calibration Curve OrderLinear or quadratic (both automatic selection and manual settings available)
CalibrationCalibration made using calibration points: (5 - 20 points)
Sample Requirement4 - 10 mL
Measurement Time10 - 600 sec
Spectrum MeasurementEnergy Axis: 0 - 10 keV, spectrum analysis to verify instrument performances.
External OutputUSB connection with PC, USB memory

Ambient Conditions

Temperature+ 5°C ~ + 40°C (+ 41°F ~ + 104°F)
Humidity80% max relative humidity in temperature range + 5°C ~ + 30°C (+ 41°F ~ + 86°F).
Linear decrease to 50% relative humidity in temperature range + 31°C ~ + 40°C (+ 88°F ~ + 104°F).

Power and Housing

Power SupplyAC 100 - 240 V ± 10 %, 50/60 Hz
Power Consumption80 VA
Dimensions [W x D x H]230 x 400 x 140 mm (9 x 15.75 x 5.5 in.)
Weight9 kg (20 lbs.)
Cooling systemAir-cooling

Conformity Standards

ASTM D4294 (USA) · ISO 8754 · JIS K2541/B7995

Schematics

Sulfur monitoring in Marine Oil with the SLFA in a growing environmental protection context
Sulfur monitoring in Marine Oil with the SLFA in a growing environmental protection context
Monitoring of Sulfur in petroleum products is an important topic in the current environmental protection context. Indeed, during combustion, Sulfur will cause acid rains and particles emissions that induce environmental and health problems. If industries and vehicles emissions have been the main target of Sulfur emission control since few tens of year, the new target is the maritime navigation. In this domain, now, the level of Sulfur is regulated by the MARPOL (International convention) Annex VI. For this specific regulation, the technique and measuring range of our SLFA series is perfectly suitable to allow the fast and accurate determination of Sulfur in Marine oil. Our compact SLFA-60 can be used on board and the SLFA-6800, with its autosampler (eight positions), will enhance the productivity of the control laboratories.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

EMGA-Expert
EMGA-Expert

산소/질소/수소 분석기

EMGA-Pro
EMGA-Pro

산소/질소/수소 분석기

EMIA-Expert
EMIA-Expert

탄소/황 분석기

EMIA-Pro
EMIA-Pro

탄소/유황 분석기

EMIA-Step
EMIA-Step

탄소/황 분석기 (인덕션 퍼니스 타입)

MESA-7220V2
MESA-7220V2

X선 형광 유중의 황/염소 분석기

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기

SLFA-60
SLFA-60

X선 형광 유황 분석기

SLFA-6000
SLFA-6000

X선 형광 유황 분석기

LO-300
LO-300

레이저 스캔 오일 필름 검출기

MESA-7220V2
MESA-7220V2

X선 형광 유중의 황/염소 분석기

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기

SLFA-60
SLFA-60

X선 형광 유황 분석기

SLFA-6000
SLFA-6000

X선 형광 유황 분석기

MESA-50
MESA-50

X선 형광 분석기

MESA-50K
MESA-50K

X선 형광 분석기

MESA-7220V2
MESA-7220V2

X선 형광 유중의 황/염소 분석기

PX-375
PX-375

PM & 중금속 분석기

SLFA-60
SLFA-60

X선 형광 유황 분석기

SLFA-6000
SLFA-6000

X선 형광 유황 분석기

XGT-9000
XGT-9000

X선 분석 현미경(Micro-XRF)

XGT-9000SL
XGT-9000SL

X선 분석 현미경 초대형 챔버 모델