APSA-370 [High Sensitivity Model]

Ambient Sulfur Dioxide Monitor

APSA-370 High Sensitivity Model is a gas analyzer for measurement of sulfur dioxide (SO2) at extremely low parts per billion level concentration.The analyzer has applied ultraviolet fluorescence (UVF) method. It has incorporated aromatic hydrocarbon cutter to reduce the interfence from the coexisting hydrocarbons. In addition, a unique design of the measurement cell enables high sensitivity and high stability of the measurement by achieving low background noise. Measurement range 0 - 10 / 20 / 50 / 100 ppb and Lower Detection Limit 0.1 ppb enables application of the analyzer for the cleanroom airborn molecular contamination monitoring, ambient air background monitoring, monitoring of the cultural property presenvation environment etc.

Application

  • Ambient air background monitoring
  • Cleanroom airborne molecular contamination monitoring
  • Monitoring of the cultural property preservation environment

 

Division: Ambient
Manufacturing Company: HORIBA, Ltd.
Base product: AP-370 Series
  • High sensitivity and high stability
    A unique design of the detector and optical system realizes high sensitivity and high stability with low background
     
  • Reduced influence of the interfering components
    Built-in aromatic hydrocarbon cutter eliminates the influence from interfering components
    UV fluorescence detector resistant to moisture interference
     
  • Automatic calibration function
    Function is available when APSA-370 (High sensitivity model) is connected with standard gas generator SGGU-610
     
  • No need to control UV lamp intensity
    Incorporated UV lamp intensity compensator
     
  • Remote operation
    Remote operation is available by LAN connection terminal (option), RS-232C (option)
     
  • Specially treated low adsorption sampling system for high precision of measurement
    Special treatment for less chemical volatilization inside sampling tube to enable high precision of measurement

 

Related Industries

 

Related Application

 

ComponentSulfur Dioxide
ModelAPSA-370 (High sensitivity model)
PrincipleUV Fluorescence method
Range0 - 10 / 20 / 50 / 100 ppb
Lower detection limit (LDL)
*Typical value under certain conditions
0.1 ppb
Response time (T90)Within 5 minutes from the analyzer sample inlet
Displayed componentsInstantaneous value of SO2
Analog output4 - 20 mA DC or 0 - 1 V DC
Communication interfaceRS-232C or TCP/IP
Sample gas flowApprox. 0.7 L/min
Operation gasN/A
Calibration gasN2based SO2 diluted by pure air from SGGU-610 or by ultra-pure air from gas cylinder
Ambient temperatureCleanroom temperature
Ambient humidityCleanroom humidity
PowerAC100 - 120 V, AC200 - 240 V
Power consumptionApprox. 150 VA in steady state
External dimensions430 (W) x 221 (H) x 650 (D) mm
MassApprox. 20 kg
Configuration
(analyzer & calibration equipment)
APSA-370 (High sensitivity model)
SGGU-610

SGGU-610: standard gas generator

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.