MU-2000 Process Gas UV Spectroscopic Analyzer

Descripción

HORIBA's comprehensive technologies are combined to achieve more advanced, reliable and accurate gas monitoring.

HORIBA offers the MU-2000, an unprecedented high quality UV spectroscopic analyzer using our innovative optical sampling and software systems.

The MU-2000 provides continuous measurement of up to five sample components. Two light sources, Xenon or Deuterium, are available depending on the wavelength band required by the application. The sample signal is transmitted via optical fibers to a holographic grating and diode array detector. Our sophisticated p-chemometrics algorithms allow simultaneous multiple component analysis over wide concentration ranges.

Featuring high reliability and great assurance, HORIBA's comprehensive technology meets the needs of process gas monitoring in the next generation.

Características

  • Exceptional optical design
    Precise measurement with minimum interference of coexistent gas, Perform multi-component measurements quickly, simultaneously, and continuously.
  • Easily expandable sampling technology
    HORIBA proprietary technology is provided comprehensively, from analyzers to whole systems.
  • HORIBA Proprietary software
    HORIBA’s proprietary analysis method outputs measured values from multiple components. Operate using an easy-touch touch screen.
  • Measure up to 5 components simultaneously and continuously
    By adopting ultraviolet spectroscopy, the MU-2000 performs continuous measurement of multi-components, not possible before using nondispersive ultraviolet absorption or gas chromatography.

Producido por HORIBA

Especificaciones

 

MU-2000N

MU-2000L

Light source

Xenon lamp

Deuterium lamp

Measurement wavelength range

230 - 600 nm

200 - 600 nm

Measurement principle

UV spectroscopy

Number of components measured simultaneously

Up to 5 components

Analog output

DC4 - 20 mA (isolated),
10 channels (max)(measurement component output 5 ch+ operation value output 5 ch)

Contact output (alarm)

Standard: Not measurable
Optional: Concentration alarm, 10 channels (max)

Dimensions

540 (W) x 294 (D) x 640 (H) mm
21.3 (W) x 11.6 (D) x 25.2 (H) in
(analyzer main body, protruding parts not included)
(MU-2000L: Installation positions of light source unit and spectroscopic unit are separate.)

Mass

Approx. 45 kg, 99 lb (analyzer)

Power supply

100 - 120 VAC / 200 - 240 VAC, 50/60 Hz

Power consumption

100 VA (analyzer)

Installation environment

0 - 40°C, 90% Rh or less

Utility (blank gas)

Nitrogen or instrument air