discontinued Dieses Produkt wurde eingestellt und ist nicht mehr verfügbar. Zu Informationszwecken kann diese Seite weiterhin aufgerufen werden.
successor
Die Eigenschaften dieses Produktes wurden in ein neues Modell integriert. Weiter zum Nachfolger

MESA-7220*

Measurement of Sulfur and Chlorine in Petroleum Products

The MESA-7220 is based on the latest advances in Energy Dispersive X-ray Fluorescence (EDXRF) technology. It utilizes a proprietary X-ray optical technology and produces a polarized, monochromatic X-ray source. This approach is critical for a user to achieve an ultra low noise background for the best limits of detection for sulfur and chlorine. This provides excellent performance at high concentration (multiple wt.% levels), simultaneous multi-element analysis and applicability over a wide range of sample types, and excellent low ppm capabilities.

*Available in the Americas. For additional information, please contact us.

Segment: Scientific
Produktionsfirma: Olympus Innov-X

• Simultaneous elemental analysis.
• One calibration – for multiple petroleum matrices over a wide dynamic range.
• Dynamic Analysis Range: Sulfur: 0.7 mg/kg – 10.0 wt% and Chlorine: 0.6 mg/kg – 10.0 wt%
• Various sample types including liquids, solids,pastes, powders, films, and pellets.
• No purge or combustion gases required.
• Correction for oxygen interference that can effect sulfur results significantly in other analyzers.
• User defined measurement times (90 - 600 seconds.)
• Single digit ppm repeatability achieved on low level samples.
• Multiple Calibration Curve capability with easy storage and retrieval for matrix matching.
• Rugged, user serviceable Kapton Windows.
• Multiple external outputs: Printer, serial I/O, USB (2) and network (RJ-45), (2 USB ports, side and back. PS2 connects, ports for mouse and keyboard,ethernet connections.)
• Accurately measures sulfur and chlorine in the presence of moisture.

X-ray TubePelletier-cooled, Ag anode X-ray tube; 0-12.5kV; 0-2mA
Polarizing Mono-chromaterClosed-coupled, doubly curved HOPG crystal reflects Ag Ka radiation for optimal excitation of S and Cl.
Si drift DetectorStable peak positions and spectral resolution (<150 eV) up to an input count rate of 200 kcps.
Dynamic Range1.0 mg/kg - 10% (wt/wt) - (1 ppm - 100,000 ppm). The sample chamber is under vacuum to enhance sensitivity.
Vacuum Chamber WindowUser replaceable 7.5 mm Kapton window. The detector is also protected by a replaceable safety window between it and the sample cup window.
Sample volume5 mL
Included Accessories and Options

• Printer

• Keyboard and mouse

Software• Create unlimited number of calibrations.
• On screen diagnostics of all operating parameters.
• An intuitive touch screen based, user interface.
• Ability to easily add new functionality.
Operating Requirements

• Nominal input voltage: 120-240 V +/- 10%AC, 50/60Hz, 125W
• Ambient operation temperature: -25˚ C to 40˚ C
• Relative humidity at 25˚ C (77˚F): 0 to 95%

Computer

• Simple, touch screen interface with a sealed, field-hardened 8.4” screen (800 x 600 px)
• Password protected, keyboard driven interface for supervisor setup.
• Direct web customer support capability.
• Powerful Pentium processor, embedded Windows OS
• 480 GB hard drive and 500 MB of RAM.
• Multiple USB port connectivity for a mouse and keyboard.

Weight21kg (45 lbs.)
Dimensions

330 mm (Width) x 508 mm (Depth) x 413 mm (Height)

(13 x 20 x 16.25 inches)

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten.

* Diese Felder sind Pflichtfelder.

Related products

MESA-7220V2
MESA-7220V2

X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

SLFA-20
SLFA-20

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-2100/2800
SLFA-2100/2800

X-ray Fluorescence Sulfur-in-Oil Analyzers

SLFA-60
SLFA-60

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

XPLORER-V*
XPLORER-V*

Next Generation Total Nitrogen and Total Sulfur Analyzer

MESA-50
MESA-50

X-Ray Fluorescence Analyzer

MESA-50K
MESA-50K

X-Ray Fluorescence Analyzer

MESA-7220V2
MESA-7220V2

X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer

PX-375
PX-375

Kontinuierlich messendes Feinstaubmessgerät mit Röntgenfluoreszenzanalyse

SLFA-20
SLFA-20

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-2100/2800
SLFA-2100/2800

X-ray Fluorescence Sulfur-in-Oil Analyzers

SLFA-60
SLFA-60

X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-6000
SLFA-6000

X-ray Fluorescence Sulfur-in-Oil Analyzer

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

XGT-9000SL
XGT-9000SL

X-ray Analytical Microscope
with a Super Large Chamber