| Product name | ORP meter |
|---|
| Model | HO-300 |
|---|
| Combined sensor | ORP electrode |
|---|
Measurable range | ORP | −2000 mV to 2000 mV (display range: −2200 mV to 2200 mV) |
|---|
| Temperature | 0℃ to 100℃ - Display range :−10℃ to 110℃
(the sensor types are detected automatically) - Display range :−20℃ to 130℃
(the sensor types are input by manually)
|
Display resolution | ORP | 1 mV |
|---|
| Temperature | 0.1℃ |
| Performance | ORP | Repeatability | Within ±5mV (response for equivalent input) |
|---|
| Linearity | Within ±5mV (response for equivalent input) |
| Temperature | Repeatability | ±0.3℃ (response for equivalent input) |
| Linearity | ±0.3℃ (response for equivalent input) |
Transmission output | Output type | 4 mA to 20 mA DC: input/output insulation type |
|---|
| Load resistance | Max.: 600Ω (case of 24 V DC power supply)*1 |
| Linearity | Within ±0.08 mA (output only) |
| Repeatability | Within ±0.02 mA (output only) |
| Output range | ORP: Selection from preset ranges or free range input within measuring range. |
| Occasional out for error | Hold or burnout to either 3.8 mA or 21 mA |
| Transmission hold | In the maintenance mode, transmission signal is held at the latest value or preset value. In the calibration mode, transmission signal can be alive or held. |
| Contact input | Number of input points | 1 |
|---|
| Contact type | No-voltage a-contact |
| Conditions | ON resistance: 40 Ω Open voltage: 1.2 V Short-circuit current: 21 mA DC max. |
| Contact function | External input for transmission holding. |
Temperature measurement | Applicable temperature element | Platinum resistor: 1 kΩ (0℃) |
|---|
Positive relation resistor with temperature: 500 Ω (25℃), 6.8 kΩ (25℃), 10 kΩ (25℃) |
| Element selection method | Automatic temperature sensor type detection or manual selection (no temperature element is selectable) |
| Calibration | ORP adjust function | Adjust (offset adjustment): −200 mV to 200 mV Span sensitivity correction: 0.500 to 1.500 |
|---|
| Temperature calibration | 1 point calibration comparing reference thermometer |
| Self-check | Calibration error | Temperature calibration error Out of temperature calibration range (for ORP sensor with RTD). |
|---|
| Electrode diagnostic error | Reference electrode impedance error (only applicable for differential circuit mode with a liquid contact electrode) Temperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range |
| Converter error | CPU, ADC, and memory errors |
| Operating temperature range | −20℃ to 60℃ (without freeze) |
|---|
| Operating humidity range | Relative humidity: 5% to 90% (without condensation) |
|---|
| Storage temperature | −25℃ to 65℃ |
|---|
| Power supply | Rated voltage | 24 V DC (operating voltage range: 21 V to 32 V DC)*1 |
|---|
| Power consumption | 0.6 W or less. |
Compatible standards | CE marking | |
|---|
| | Compatible standards | EMC directive: EN61326-1 RoHS Directive: EN50581 |
| Immunity | Industrial electromagnetic environment |
| Electostatic discharge | IEC61000-4-2 |
| Electromagnetic field of radiated radio frequency | IEC61000-4-3*2 |
| Electric fast transient/burst | IEC61000-4-4 |
| Surge | IEC61000-4-5*3 |
| Conducted interference induced by radio frequency | IEC61000-4-6*2 |
| Emission | Class A |
| Radiated disturbance | CICPR 11 CLASS A |
| FCC Rules | Part15 CLASS A |
| Structure | Installation | Outdoor installation type |
|---|
| Installation method | Mounted on 50 A pole or wall |
| Protection code | IP65 | IEC60529, JIS C0920 |
| Case material | Aluminum alloy (coated with epoxy-denatured melamine resin) |
| Material of fittings | SUS304 |
| Material of hood | SUS304 (coated with epoxy modified melanine resin) |
| Material of window | Polycarbonate |
| Display element | Reflective monochrome LCD |
| External dimensions | 180 (W) mm × 155 (H) mm × 115 (D) mm (excluding mounting brackets) |
|---|
| Mass | Main body: approx. 2.8 kg, Hood and mounting brackets: approx. 1 kg |
|---|