Oil Content Analyzer
OCMA-550 to measure residual oil on components and concentrations of oil adhered on solids such as soil.
Measurement can be easily made only by injecting the extracted water sample into the attached cell and setting it to the equipment.
This model features a simple design which allows opening/closing of the door to setting of cell with just one hand.
This is best for measurement of extracted samples such as evaluation of residual oil on components and measurement of oil contained in food.
How to measure:
Cell is easily detactable with just one hand
Simple design which allows opening/closing of door and detachment of cell with just one hand. Measurement operation becomes smoother.
Fully used in Various Applications
Residual oil on components For quality control of components | For piping of air conditioners and refrigerators To prevent reduction of cooling function | Semiconductor field For evaluation of degreasing capacity | Others Useful for soll (environmental pollution), |
Model | OCMA-550 |
---|---|
Product name | Oil content analyzer |
Measurement method | Solvent extraction - non-dispersive infrared absorption analysis method |
Measured objects | Substances extracted from sample water into solvent and having infrared absorption near a wavelength from 3.4 μm to 3.5 μm |
Measurement range | 0 mg/L to 200 mg/L |
Resolution | For mg/L 0 to 99.9: 0.1, 100 to 200: 1 For mg/g, mg/kg, mg/PC 0 to 9.99: 0.01, 10.0 to 99.9: 0.1, 100 to 200: 1 Abs.: 0 to 1.000 Abs.: 0.001 Abs. |
Repeatability | 0 mg/L to 9.9 mg/L: ±0.4 mg/L ±1 dig. 10.0 mg/L to 99.9 mg/L: ±2.0 mg/L ±1 dig. 100 mg/L to 200 mg/L: ±4 mg/L ±1 dig. * For standard liquids |
Display method | 3.5 inches, 320×240 dots Backlight Color graphic LCD |
Calibration method | Select each optionally zero calibration and span calibration |
Extraction solvent | S-316 |
Amount of extraction solvent required | Approx. 6.5 mL |
Extraction method | Using the extraction solvent, and extracted manually outside the product |
Ambient operating temperature | 0°C to 40°C (no condensation) |
Power supply | 100 V to 240 V AC ±10%, 50/60 Hz |
Power consumption | 100 V to 240 V AC, Approx. 60 VA |
External dimensions | 195 (H) × 253 (W) × 293 (D) mm |
Mass | Approx. 5 kg |
External output | Output to a USB memory stick |
Functions |
|
Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.
Automated Organic Analysis & Early Warning Sentinel
For Instant Water Quality Reports
Total Nitrogen and Sulfur Analyzer
Total Halogen and Sulfur Analyzer
Air Pollution Monitor
Oxygen/Nitrogen/Hydrogen Analyzers
Carbon/Sulfur Analyzer
Stack Gas Analysis System
Stack Gas Analyzer
Motor Exhaust Gas Analyzer
On-board Emissions Measurement System
On-board Emissions Measurement System for NH3/N2O
Portable Gas Analyzer
Multi-Component Gas Analyzer