CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

ν‚€μ›Œλ“œ: 3D NAND, SiN(Silicon Nitride), Etching, Hot phosphoric acid

3D NAND 제쑰 κ³΅μ •μ—μ„œλŠ” μˆ˜μ‹­ 개의 SiO2 및 SiN 측이 증착되고 SiN 측은 고온 인산을 μ‚¬μš©ν•˜μ—¬ μ„ νƒμ μœΌλ‘œ μ œκ±°λ©λ‹ˆλ‹€. 이 κ³Όμ •μ—μ„œ μ•½μ•‘μ˜ 농도와 μ˜¨λ„λ₯Ό μ‘°μ ˆν•˜μ—¬ μ›ν•˜λŠ” μ‹κ°μœ¨μ„ 얻을 수 μžˆμŠ΅λ‹ˆλ‹€. κΈ°μ‘΄ μ œν’ˆμ€ 고온의 μ•½ν’ˆμ„ μΈ‘μ •ν•˜κΈ° μ–΄λ €μ› μ§€λ§Œ CS-620FλŠ” 170λ„κΉŒμ§€ κ³ μ˜¨μ—μ„œ 츑정이 κ°€λŠ₯ν•©λ‹ˆλ‹€. 연속 츑정은 흑수 뢄광법을 μ‚¬μš©ν•˜μ—¬ 이루어지며, λ‹€λ₯Έ 방법에 λΉ„ν•΄ μœ μ§€ 관리가 덜 ν•„μš”ν•˜κ³  μ†Œλͺ¨ν’ˆ μ†Œλͺ¨κ°€ μ μŠ΅λ‹ˆλ‹€.

Segment: Semiconductor
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Key features

High concentration phosphoric acid up to 92% can be measured

No cooling mechanism and cooling time is needed.
Direct measurement is possible without cooling high-temperature phosphoric acid (140 to 170Β°C) in the circulation line.

PFA is used in the sample wetted area to reduce contamination risk.

Contributes to significant reduction in equipment downtime by adopting semi-annual background correction cycles.

Contributes to faster concentration feedback control by updating measured data every 3 seconds

Stability

β–Ά Measurement results
The sample (actual solution) measured for 1 hour shows exellent stability.

β–Ά Measurement conditions
Measurement Cycle: every 3 seconds   Measurement time: 1 hour   Moving average: 16 times 
Sample concentration (Initial Sample Concentration)   H3PO4: 92.2%   H2O: 7.8%   Sample temperature: 141Β°c

Recommend Products


CS-700
High Precision, High Stability
Chemical Concentration Monitor

CS-600F
Fiber Optic Type Chemical
Concentration Monitor

HF HD-960L
Dissolved Oxygen Monitor
in Low Concentration
Product nameCHEMICAL SOLUTION MONITOR
ModelCS-620F
Measurement principleAbsorption spectroscopic method
Calculation principleTemperature compensation type multivariate analysis
SampleH3PO4/H2O

Measurable range
Repeatability

 ComponentMeasurable range
(mass%)
Repeatability
(mass%)
Analog output
range(mass%)
1st solutionH3PO485.00-92.00+/-0.1085.00-100.00
H2O8.0-15.0+/-0.30.0-15.0
・ Repeatability is defined by maximum error from average (1 hour).
・ In the case of low temperature measurement (140Β°C) and high temperature measurement (170Β°C) with the same chemical,
there is possibility of discrepancy (Maximum +/- 0.30%).
Conditions
of Measurement
1) Measurement interval: Approx. 3 sec. (minimum)
2) Moving average: 16 times
Connection fitting size1 inch or 3/4 inch
Sample conditionSample temperature: 140 to 170Β°C
Atmospheric temperature, Chemical temperature fluctuation: within +/- 1Β°C (period of time : 1 hour)
Input pressure: 0.2 MPa or less
Pressure fluctuation: 0.02 MPa or less
Flow rate: 1 to 30 L/min
Air(for operation and purge)Connection port: 4 mm O.D. quick joint
Pressure: 0.2 MPa Β± 0.02 MPa
Power source100 to 230 V AC (Single-Phase), 50/60 Hz
Power consumptionApprox.85 VA (Transient electric current at the time of the start is excluded)
CommunicationParallel I/O, RS-232C, Analog output
Dimension(Monitor) 200 (W) Γ— 308 (D) Γ— 78 (H) mm
(Lamp unit) 200 (W) Γ— 262 (D) Γ— 100 (H) mm
(Sample cell) 240 (W) Γ— 209 (D) Γ— 205 (H) mm
Weight(Monitor) Approx.3.6 kg
(Lamp unit) Approx.2.8 kg
(Sample cell) Approx.3.0 kg
Ambient temperature(Monitor, Lamp unit) 20 to 30Β°C
(Optical fiber, Sample cell) 20 to 100Β°C
* Sudden temperature change should be avoided, within +/- 1Β°C/1hour
Ambient humidity(Monitor, Lamp unit) 40 to 70% (Should be no dew condensation)
Slanting angle of installation(Monitor, Lamp unit) Within +/-1 degree
(Sample cell) Please install so that air bubbles do not stay up.
Optical fiberLength: 5 m, Bend radius: R150 mm

μ œν’ˆ 문의

HORIBAμ œν’ˆμ˜ μžμ„Έν•œ 정보λ₯Ό μ›ν•˜μ‹œλ©΄, μ•„λž˜μ˜ 양식에 λ‚΄μš©μ„ μž…λ ₯을 λΆ€νƒλ“œλ¦½λ‹ˆλ‹€.

* λŠ” ν•„μˆ˜μž…λ ₯ν•­λͺ©μž…λ‹ˆλ‹€.

Related products

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

HC-200F
HC-200F

ν˜„μž₯μ„€μΉ˜ν˜• λΆˆμ†Œμ΄μ˜¨μΈ‘μ •κΈ°(4-Wire Transmission)

HC-300F
HC-300F

ν˜„μž₯μ„€μΉ˜ν˜• λΆˆμ†Œμ΄μ˜¨μΈ‘μ •κΈ°(2-Wire Transmission)

HD-200
HD-200

ν˜„μž₯μ„€μΉ˜ν˜• μš©μ‘΄μ‚°μ†ŒμΈ‘μ •κΈ°(4-Wire Transmission), λ©€λΈŒλ ˆμΈν˜•)

HD-200FL (Four-Wire Transmission, 광학식)
HD-200FL (Four-Wire Transmission, 광학식)

ν˜„μž₯ μ„€μΉ˜ν˜• 용쑴 μ‚°μ†Œ μΈ‘μ •κΈ°

HD-300
HD-300

ν˜„μž₯μ„€μΉ˜ν˜• μš©μ‘΄μ‚°μ†ŒμΈ‘μ •κΈ°(2-Wire Transmission), 멀브레인 ν˜•)

HD-480
HD-480

μš©μ‘΄μ‚°μ†ŒμΈ‘μ •κΈ°(4-Wire Transmission), 멀브레인 ν˜•)

HD-960L
HD-960L

저농도 용쑴 μ‚°μ†Œ λͺ¨λ‹ˆν„°

HD-960LR
HD-960LR

용쑴 μ‚°μ†Œ 농도 λͺ¨λ‹ˆν„°

HE-200C
HE-200C

ν˜„μž₯μ„€μΉ˜ν˜• 전기전도도계(4-Wire Transmission, μ €λ†λ„μš©)

HE-200H
HE-200H

ν˜„μž₯μ„€μΉ˜ν˜• 전기전도도계(4-Wire Transmission, κ³ λ†λ„μš©)

HE-200R
HE-200R

ν˜„μž₯ μ„€μΉ˜ν˜• 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

ν˜„μž₯ μ„€μΉ˜ν˜• 전기전도도계 (2-Wire Transmission, μ €λ†λ„μš©)

HE-300C-IS ( λ°©ν­ν˜• )
HE-300C-IS ( λ°©ν­ν˜• )

λ°©ν­ν˜• μ„€μΉ˜ νƒ€μž… COND meter ( Low concentrtion )

HE-300R
HE-300R

ν˜„μž₯ μ„€μΉ˜ν˜• 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

νŒ¨λ„ μž₯μ°©ν˜• 전도도계(4-Wire Transmission, μ €λ†λ„μš©)

HE-480C-GC
HE-480C-GC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (μ €λ†λ„ν˜•)

HE-480H
HE-480H

νŒ¨λ„ μž₯μ°©ν˜• 전도도계(4-Wire Transmission,μ €λ†λ„μš©)

HE-480H-DC24V
HE-480H-DC24V

νŒλ„¬ μž₯μ°©ν˜• 전도도계(4-wire Transmitter , κ³ μ „λ„λ„μš©)

HE-480R
HE-480R

νŒ¨λ„ μž₯μ°©ν˜• 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

ꡬ연산 λͺ¨λ‹ˆν„°

HE-960CW
HE-960CW

νŒ¨λ„ μž₯μ°©ν˜• 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH λͺ¨λ‹ˆν„°

HE-960H-TM-S
HE-960H-TM-S

κ³ μ •λ°€ TMAH 농도 λͺ¨λ‹ˆν„°

HE-960HC
HE-960HC

μΉ΄λ³Έ μ„Όμ„œ 전도도계 (κ³ λ†λ„ν˜•)

HE-960HI
HE-960HI

νŒ¨λ„ μž₯μ°©ν˜• 전도도계(4-Wire Transmission, κ΄‘μ—­μš©)

HE-960LC
HE-960LC

μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 μΉ΄λ³Έ μ„Όμ„œ 전도도계

HE-960RW
HE-960RW

νŒ¨λ„ μž₯μ°©ν˜• 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 μ €ν•­λ₯ κ³„

HF-960EM
HF-960EM

인라인 μ„Όμ„œ 및 μžλ™ λ²”μœ„ μ „ν™˜ 농도 λͺ¨λ‹ˆν„°

HF-SP-CU
HF-SP-CU

2-채널 κ³ μ •λ°€ HF 농도 λͺ¨λ‹ˆν„°

HO-480
HO-480

νŒ¨λ„ μž₯μ°©ν˜• ORP λ―Έν„° (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ν˜„μž₯ μ„€μΉ˜ν˜• pH Meter

HP-300
HP-300

ν˜„μž₯ μ„€μΉ˜ν˜• pHλ―Έν„° (2-Wire Transmission)

HP-480
HP-480

νŒ¨λ„ μž₯μ°©ν˜• pHλ―Έν„° (4-Wire Transmission)

HP-480PL
HP-480PL

νŒ¨λ„ μž₯μ°©ν˜• pH λ―Έν„°(4-Wire Transmission, νŽ„μŠ€ λΉ„λ‘€ μ œμ–΄)

HP-480TP
HP-480TP

νŒ¨λ„ μž₯μ°©ν˜• pH λ―Έν„°(4-Wire Transmission, μ‚°μ—…μš© μ‹œλΆ„ν•  λΉ„λ‘€μ œμ–΄)

HP-960FTP
HP-960FTP

νŒ¨λ„ μž₯μ°©ν˜• pH λ―Έν„°(4-Wire Transmission, 4 포인트 μ•ŒλžŒ, μ‹œλΆ„ν•  λΉ„λ‘€ μ œμ–΄)

HR-200
HR-200

ν˜„μž₯ μ„€μΉ˜ν˜• μž”λ₯˜μ—Όμ†Œ μΈ‘μ •κΈ° (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

ν˜„μž₯ μ„€μΉ˜ν˜• μž”λ₯˜ μ—Όμ†Œ μΈ‘μ •κΈ° (4-Wire Transmission, Rotating Type)

HR-480
HR-480

μž”λ₯˜ μ—Όμ†Œ μΈ‘μ •κΈ° (4-Wire Transmission)

HT-110
HT-110

μ΄μœ κΈ°νƒ„μ†Œ λͺ¨λ‹ˆν„°

HZ-960
HZ-960

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960HPO-M
HZ-960HPO-M

H2O2 λͺ¨λ‹ˆν„°

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

OPSA-150
OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

SLIA-300
SLIA-300

고감도 싀리카 뢄석기

SLIA-5000
SLIA-5000

싀리카 μΈ‘μ •κΈ°

TPNA-500
TPNA-500

μžλ™ μ΄μ§ˆμ†Œ/총인 μΈ‘μ •κΈ°

TW-100
TW-100

μžλ™ 수질 μΈ‘μ •μž₯치

TW-150
TW-150

Online Water Quality Monitor (곡정 수질 μΈ‘μ • μ‹œμŠ€ν…œ)

U-50 Series
U-50 Series

λ‹€ν•­λͺ© 수질 μΈ‘μ •κΈ°

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

CS-620F
CS-620F

κ΄‘μ„¬μœ ν˜• 고온 인산 농도 λͺ¨λ‹ˆν„°

CS-900
CS-900

비접촉 ν™”ν•™λ¬Όμ§ˆ 농도 λͺ¨λ‹ˆν„°

HU-200SS
HU-200SS

ν˜„μž₯μ„€μΉ˜ν˜• MLSS Meter (4-Wire Transmission)

HU-200TB-H
HU-200TB-H

ν˜„μž₯μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, High-sensitivity)

HU-200TB-IM
HU-200TB-IM

κ³΅μ •μš© μ‚½μž…ν˜• SS/탁도 μΈ‘μ •κΈ°

HU-200TB-W
HU-200TB-W

ν˜„μž₯ μ„€μΉ˜ν˜• 탁도계 (4-Wire Transmission, For Wide Range)

HZ-960
HZ-960

μš©ν•΄ 였쑴 λͺ¨λ‹ˆν„°

HZ-960HPO-M
HZ-960HPO-M

H2O2 λͺ¨λ‹ˆν„°

OPSA-150
OPSA-150

μœ κΈ°μ˜€μ—Όλ¬Όμ§ˆ λͺ¨λ‹ˆν„°

TPNA-500
TPNA-500

μžλ™ μ΄μ§ˆμ†Œ/총인 μΈ‘μ •κΈ°

U-50 Series
U-50 Series

λ‹€ν•­λͺ© 수질 μΈ‘μ •κΈ°