Deep Cooled UV/Vis/NIR
HORIBA offers a complete line of spectroscopic multi-channel detectors for scientific research. For spectral detection from UV to near-IR, two dimensional CCDs and indium gallium arsenide linear arrays offer a faster acquisition option over single point detectors with relatively high sensitivity. Coupled with HORIBA’s range of aberration corrected, flat field imaging spectrographs, custom spectroscopy packages can be assembled for a variety of applications.
*OE- open electrode, FIUV- front illuminated UV enhanced, FIVS- front illuminated visible, BIUV- back illuminated UV enhanced, BIVS- back illuminated visible, BIDD- back illuminated deep depletion
| Cooling | Type* | Peak QE | Array Dimension | Pixel Size |
---|---|---|---|---|---|
Syncerity | TE -60°C | 58% | 1024 x 256 | 26µm x 26µm | |
TE -50°C | 78% | 2048 x 70 | 14µm x 14µm | ||
SynapsePlus High Speed CCD | TE -80°C | 56% | 1024 x 256 | 26µm x 26µm | |
47% | 2048 x 512 | 13.5µm x 13.5µm | |||
48% | 2048 x 512 | 13.5µm x 13.5µm | |||
95% | 1024 x 256 | 26µm x 26µm | |||
75% | 1024 x 256 | 26µm x 26µm | |||
<90% | 1024 x 256 | 26µm x 26µm | |||
Synapse CCD | TE -75°C | ||||
56% | 512 x 512 | 24µm x 24µm | |||
95% | 512 x 512 | 24µm x 24µm | |||
75% | 512 x 512 | 24µm x 24µm | |||
Symphony II CCD | LN2-133°C | 58% | 1024 x 256 | 26µm x 26µm | |
56% | 1024 x 256 | 26µm x 26µm | |||
58% | 1024 x 256 | 26µm x 26µm | |||
95% | 1024 x 256 | 26µm x 26µm | |||
75% | 1024 x 256 | 26µm x 26µm | |||
95% | 1024 x 256 | 26µm x 26µm |
*OE- open electrode, FIUV- front illuminated UV enhanced, FIVS- front illuminated visible, BIUV- back illuminated UV enhanced, BIVS- back illuminated visible, BIDD- back illuminated deep depletion
*FIUV- front illuminated UV enhanced, FIVS- front illuminated visible, BIUV- back illuminated UV enhanced, BIVS- back illuminated visible, BIDD- back illuminated deep depletion
Cooling | Type* | Peak QE | Array Dimension | Pixel Size | |
---|---|---|---|---|---|
Synapse EMCCD | TE -60°C | 49% | 1600 x 200 | 16µm x 16µm | |
49% | 1600 x 200 | 16µm x 16µm | |||
95% | 1600 x 200 | 16µm x 16µm | |||
95% | 1600 x 200 | 16µm x 16µm | |||
92% | 1600 x 200 | 16µm x 16µm |
*OE- open electrode, FIUV- front illuminated UV enhanced, FIVS- front illuminated visible, BIUV- back illuminated UV enhanced, BIVS- back illuminated visible, BIDD- back illuminated deep depletion
Cooling | Wavelength | Array Dimension | Element Size | |
---|---|---|---|---|
Synapse InGaAs | TE -60°C
| 800-1650 nm | 512 x 1 | 25µm x 500µm |
1050-2100 nm | 512 x 1 | 25µm x 250µm | ||
Symphony II InGaAs | LN2-103°C | 800-1600 nm | 512 x 1 | 25µm x 500µm |
1000-2050 nm | 512 x 1 | 25µm x 250µm |
如您有任何疑問,请在此留下詳細需求或問題,我們將竭誠您服務。
Dual Mode Analog/Photon Counting PMT
High Resolution Monochromators