VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer VA-5000 Series

Multi-Component Gas Analyzer

The Multi-Component Gas Analyzer VA-5000 Series is an all-round analyzer that satisfies measurement needs as required for environmental monitoring, energy development support, quality controls, and continuous emission monitoring, etc. The VA-5000 Analyzer can be configured with up to 4 detector modules within a single case. Many combinations of detector modules with a wide selection of ranges allows this series of analyzers to be used for a variety of applications. The VS-5000 Sample Gas Conditioning Systems are designed to support the VA-5000 Analyzers by proving the optimal sample conditions for measurement. We also have wall mounted type analyzer (VA-5000WM) that enables to install in a limited installation space.

Division: Process Gas
Manufacturing Company: HORIBA, Ltd.
  • Versatility for Various Applications

    ・ Simultaneous measurement of up to four gas components. (CO, CO2, CH4, N2O, NO, SO2, NH3, NOx, O2, Siloxane)
    ・ Auto pressure compensation provides stable measurements by compensating for barometric pressure changes
    ・ Employs a thermostatically controlled gas flow sensor to increase accuracy of measurements.

  • Ease of Use
    ・ A 5.7 inch LCD touchscreen provides analyzer information measurement status, trend graphs, diagnostics and analyzer settings
    ・ Detector modules can be added or replaced quickly
    ・ A front panel USB allows instrument instant settings to be logged in addition to sample data

          
     
  • Additional Features
    ・ Auto-calibration
    ・ Blowback control
    ・ Self-diagnosis
    ・ Data logging
    ・ Analyzer configuration settings
    ・ Multiple analog and digital outputs (option)
                                  
  • VA-5000 Series Sample Gas Conditioning Systems
    ・ Designed to support the VA-5000 Series Analyzers
    ・ Convenient 19-inch rack mount configuration
    ・ Integrates pumps, coolers, filters, flow controls, NOx converters, etc., within a single case

 

Related Industries

 

Related Application
 

Specifications of the VA-5000 / VA-5000WM Analyzer

Measurement principleNDIRCLAMagnetopneumaticGalvanic cellZirconiaParamagnetic
PerformanceLinearityStandard±1.0% F.S.
Option±2.0% F.S.(range ratio 1:20)-----
Response time30 sec or less (T90), 40 sec or less (Td+T90); single component*145 sec (Td+T90)
Warm-up time60 min (90 min for SO2)60 min60 min40 min20 min120 min
Flow rateStandard0.5L/min0.3L/min0.5L/min0.5L/min0.5L/min0.5L/min
Option1.0L/min*2----1.0L/min*2
CommunicationEthernet (ModbusTM/TCP)
Data storageOptionUSB memory
Input/Output (option)AnalogInputMaximum 4ch, 0-16 mA / 4-20 mA / 0-20 mA or 0-1 V isolated
OutputMaximum 8ch, 0-16 mA / 4-20 mA / 0-20 mA or 0-1 V isolated, Current output: load resistance < 750Ω, Voltage output: input impedance > 100k Ω
DigitalInputMaximum 16ch isolated, Open voltage: 24 V, Short-circuit current 10mA
Maximum load resistance < 50 Ω, Minimum pulse width: 0.5 sec
OutputMaximum 16ch isolated, Maximum voltage DC 30 V, Maximum current 1A
Minimum voltage DC 0.1 V, Minimum current 0.1 mA
Sample conditionAmbient temperature, dust free, H2O less than 5°C saturation, Pressure 0 to 490 Pa
Other: Shall contain no corrosive gas, combustible gas, and explosive gas.
Gas connectionsInlet and outlet - 6 mm/4 mm PTFE: a single gas inlet is provided standard; the gas flows sequentially from one module to the next; as an option separate gas inlets can be provided for each module
Gas tubingPTFE; stainless steel optional
JointSample Inlet: Rc 1/8(φ6/φ4mm PTFE joint), Exhaust: φ6/φ4mm PTFE joint
Air Inlet: Rc 1/8(φ6/φ4mm PTFE joint); installed CLA. CLA: Exhaust: φ6/φ4mm PTFE joint; installed CLA,
MPA Outlet: φ6/φ4mm PTFE joint; installed MPA, Zero gas Outlet: φ6/φ4mm PTFE joint; installed MPA
InstallationTemperature 0-45°C, Humidity 90% (No condensation), Altitude Max 3000m (combination with only NDIR), (combination with Zirconia, Galvani, MPA, and CLA: max 2000m), No fluctuation of backpressure
Protection degreeEquivalent to IP20
Power100-240 V AC (±10%, maximum voltage 250 VAC), 50/60 Hz (±1.0%), Consumption: 100 to 350 VA
Display5.7-inch touch screen
CaseVA-5000: 19-inch panel mount / VA-5000WM: Mounted on wall
Exterior dimensionsVA-5000: 430 (W) × 380 (D) × 132 (H) mm / Approx. 17 (W) × 15 (D) × 5.2 (H) in
Deozonator unit for CLA: 111 (W) × 95 (D) × 100 (H) mm / Approx. 4.4 (W) × 3.7 (D) × 3.9 (H) in *protrusions excluded
VA-5000WM: 424 (W) × 206 (D) × 484 (H) mm / Approx. 17 (W) x 8 (D) x 19 (H) in *protrusions excluded
MassVA-5000: 7-18kg, Approx. 15-40lb / VA-5000WM: 14-24kg, Approx. 31-53lb

*1 When single component: flow rate is 0.5L/min (CLA: 0.3L/min)
*2 Available when all components are NDIR and PMA

See full Specifications including Dimensional Outlines of VA-5000/WM Analyzer and VS-5000 Sampling Unit (PDF)

 

Specifications of the VS-5000 Sampling Unit

ModelVS-5001VS-5002VS-5003VS-5004
Applicable principlesNDIR, Zirconia, Galvanic cell, PMANDIR, Zirconia, Galvanic cell, MPA, PMANDIR, Zirconia, Galvanic cell, CLA, PMANDIR、Zircoia, Galvanic cell, MPA, CLA, PMA
Form19 inch panel mount
Sampling method5°C dry sampling
MaterialsSUS, PP, PVC, PVDF, PTFE, FKM, CR, Glass
Flow rate1.5~5.0 L/min
Sample supply0.5 L/min x 2 systems*10.3L/min x 1system
Power100~240 V AC (±10%, maximum voltage 250V AC), 50/60 Hz (±1%)
Power consumption150 VA200 VA
JointSample inlet: φ8/φ6 mm PTFE joint, Sample outlet: φ6/φ4 mm PTFE joint
Air outlet: φ6/φ4 mm PTFE joint, MPA inlet: φ6/φ4 mm PTFE joint
Regulator: φ6/φ4 mm PTFE joint, Calibration inlet: RC1/8(φ6/φ4mm PTFE joint)
Bypass outlet/Exhaust/Drain outlet: φ8mm hose end
Sample gasAmbient temperature, Dust: less than 0.1mg/m3, H2O: less than 60°C saturation with drain pot (Approx. 25% H2O), Pressure: ±980 Pa, SO3: less than 50ppm, NO2: less than 6ppm*2 , (Corrosive gas, flammable gas and explosive gas are not included)
Dimension430 (W) x 550 (D) x 221 (H) mm / Approx. 17 (W) x 22 (D) x 8.7 (H) in (protrusions excluded)
Mass14kg / 31lb16kg / 35lb19kg / 42lb20kg / 44lb

*1 Environmental temperature needs to be less than 35°C. If it's over 35°C, please consult HORIBA.
*2 When the sample gas includes more than 6ppm NO2, it needs to use optional NOX converter.

See full Specifications including Dimensional Outlines of VA-5000/WM Analyzer and VS-5000 Sampling Unit (PDF)

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

AQMS
AQMS

Ambient Air Quality Monitoring System

CEMS
CEMS

Continuous Emission Monitoring System

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

GI-700 series
GI-700 series

Stack Gas Analyzer

PG-300 series
PG-300 series

Portable Gas Analyzer

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 series
AP-370 series

Air Pollution Monitor

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

APHA-370
APHA-370

THC Analysator

APMA-370
APMA-370

Ambient Carbon Monoxide Monitor

APNA-370
APNA-370

Ambient NOx Monitor

APNA-370/CU-2
APNA-370/CU-2

Ambient Ammonia Monitor

APOA-370
APOA-370

Ambient Ozone Monitor

APSA-370
APSA-370

Ambient Sulfur Dioxide Monitor

APSA-370/CU-1
APSA-370/CU-1

Ambient Hydrogen Sulfide Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

CEMS
CEMS

Continuous Emission Monitoring System

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

GA-370
GA-370

Trace Gas Monitor

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

On-board NH3/N2O Measurement System for real-world driving

PG-300 series
PG-300 series

Portable Gas Analyzer

Process
Process

Process Analyzer System

TX-100
TX-100

Tunable Laser Gas Analyzer

51 series
51 series

Explosion-proof Gas Analyzer

AP-370 series
AP-370 series

Air Pollution Monitor

APCA-370
APCA-370

Ambient Carbon Dioxide Monitor

APMA-370
APMA-370

Ambient Carbon Monoxide Monitor

APNA-370
APNA-370

Ambient NOx Monitor

APNA-370/CU-2
APNA-370/CU-2

Ambient Ammonia Monitor

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzers
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen/Hydrogen Analyzers (Entry Model)

EMIA-Expert
EMIA-Expert

Carbon/Sulfur Analyzer

EMIA-Pro
EMIA-Pro

Carbon/Sulfur Analyzer

EMIA-Step
EMIA-Step

Carbon/Sulfur Analyzer

ENDA-5000 series
ENDA-5000 series

Stack Gas Analysis System

GA-370
GA-370

Trace Gas Monitor

GI-700 series
GI-700 series

Stack Gas Analyzer

IR-300
IR-300

Vapor Concentration Monitor

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

Laser scanning Oil Film Detector

MEXA-1170HCLD
MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

On-board NH3/N2O Measurement System for real-world driving

OCMA-500
OCMA-500

Oil Content Analyzer

OCMA-550
OCMA-550

Oil Content Analyzer

PG-300 series
PG-300 series

Portable Gas Analyzer

TX-100
TX-100

Tunable Laser Gas Analyzer