LAQUAtwin Ca-11

LAQUAtwin Ca-11 CompactMeters

Pocket Water Quality Meters

Your lab-in-a-pocket
HORIBA's unique compact meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop.

Segment: Scientific
Division: Water Quality
Produktionsfirma: HORIBA Advanced Techno Co., Ltd.

Ca2 temp

Waterproof Microvolume Back light 2pt_cal

 

The only pocket meter that directly measures calcium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.

  • Minimum sample volume: 0.3ml (0.05ml with sampling sheet B)
  • Up to 2 calibration points
  • Auto standard recognition: 150 & 2000ppm calcium (default)
  • Changeable high and low calibration values
  • Multiplication compensation: 0.01 to 9.90
  • Temperature and mV display
  • Temperature calibration: 5 to 40.0 ºC
  • Auto hold / auto stable measurement
  • Auto power off: 30 mins.
  • Low battery indicator
  • IP67 Rating dust & waterproof
  • Replaceable sensor
  • 400 Hours battery life: continuous use without backlight
  • Material: ABS epoxy
  • Display: custom (monochrome) digital LCD with backlight
  • Operating conditions: 5 to 40 ºC, 85% or less relative humidity
  • Warranty: 2 years - meter, 6 months - sensor
  • Packed in handy carrying case
  • Supplied with 150 & 2000ppm calcium standards, 5 x sampling sheets B, 2 x CR2032 batteries, dropper, instruction and quick manuals
ModelCa-11
Measurement PrincipleIon Selective Electrode
Minimum Sample Volume0.3ml (0.05ml with sampling sheet B)
Measurement Range

4 to 9900 ppm (mg/L)

0.1 to 250 mmol/L

Resolution

0 to 99 ppm: 1 ppm

100 to 990 ppm: 10 ppm

1000 to 9900 ppm: 100 ppm

Accuracy± 20% of actual value
Calibration PointsUp to 2
Temperature Display0 to 50.0 ºC
Temperature Calibration5 to 40.0 ºC
DisplayCustom (monochrome) digital LCD with backlight 
Operating Temperature5 to 40.0 ºC
Operating Humidity85% or less relative humidity (no condensation)
PowerCR2032 batteries (2)
Battery LifeApprox. 400 hours in continuous use without backlight
MaterialABS epoxy
Dimensions164 x 29 x 20 mm (excluding projections)
MassApprox. 55 g (including sensor and batteries)
Functions 
  • Auto Standard Recognition
  • Changeable High and Low Calibration Values
  • Multiplication Compensation
  • Temperature Calibration
  • Auto Hold / Auto Stable Measurement
  • Switchable Backlight
  • Automatic Power Off (30mins)
  • Low Battery Indicator
  • IP67 Dust / Waterproof
  • Replaceable Sensor
 
Quick Nutrient Analysis in Strawberry Production
Quick Nutrient Analysis in Strawberry Production
Measurement of Calcium in Milk and Milk Beverages
Measurement of Calcium in Milk and Milk Beverages
It is often necessary to determine the calcium content of milk and milk beverages. This may be done by atomic absorption spectroscopy (AA) or inductively coupled plasma atomic emission spectroscopy (ICP). Alternatively, by ionizing protein-bound calcium using an acidizing pretreatment, the LAQUAtwin Ca2+ can be used to measure the total amount of calcium easily.
Measurement of Calcium in Drinking Water
Measurement of Calcium in Drinking Water

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

Aqualog - Water Treatment Plant Analyzer
More Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

Aqualog Datastream
More Aqualog Datastream

For Instant Water Quality Reports

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

HC-200F
More HC-200F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
More HC-200NH

Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)

HC-300F
More HC-300F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200FL
More HD-200FL

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
More HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
More HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

514-05
More 514-05

0.5% NaCl Standard Solution

514-22
More 514-22

1.41 mS/cm Conductivity Standard Solution

514-23
More 514-23

12.9 mS/cm Conductivity Standard Solution

514-50
More 514-50

5.0% NaCl Standard Solution