Sample Cell Accessories (MESA-50 Series)

HORIBA provides various types of sample cells to make it possible to analyze liquid, cream, and power state samples by the HORIBA MESA-50 Series. Find best cell accessory for yourself!

Quick Instruction

  • Check the chemical resistance of each part to your sample before you start assembling.
  • Select a suitable cell according to your sample amount, sample volatility, the chemical resistance to your sample, and your analysis frequency.
  • Refer the detailed information in the below disclaimer and an instrumction manual which comes with your analyzer.


Selection Guide

For quick assembly without tools
Sample cell

Required items

  • Sample cell (3200498276, 1 pc)
  • Cell window (3014065886, 100 sheets/box)


Detailed information

  • Inner size of the cell : Φ23 mm × 22 mm (H)
  • Cell material: PP
  • Cell window material: PET
  • Required sample amount for quantitative analysis: Approximately 3.5 mL  (water base)

 

For high chemical resistance
Teflon cell

Required items

  • Teflon cell (3200043600, 1 set)
  • Cell window (3014065886, 100 sheets/box)
  • Cell-assembling jig (3014061196, 1 set/box)


Detailed information

  • Inner size of the cell : Φ20 mm x 19 mm (H)
  • Cell material: PTFE
  • Cell window material: PET
  • Required sample amount for quantitative analysis: Approximately 2.2 mL (water base)

High efficiency for routine analysis
Disposable sample cell

Required items

  • Disposable sample cells (3200847450, 48 pcs/box)
  • Cell window (3014065886, 100 sheets/box)
  • Jig for cell assembly (3014050344, 1 set/box)


Detailed information

  • The innerc size : Φ38 mm x 18 mm (H)
  • Cell material: Ionomer resin
  • Cell window material: PET
  • Required sample amount for quantitative analysis: Approximately 8 mL (water base)

Economical choice for less analysis frequency
a PET cell

Required items

  • PET cell (3200044230, 100 pcs/box)
  • Inner frame (3200044422, 1 pc)
  • Outer frame (3200044421, 1 pc)
  • Cell window (3014065886, 100 sheets/box)
  • Cell-assembling jig (3014061196, 1 set/box)


Detailed information

  • The innerc size : Φ36 mm ×18 mm (H)
  • Cell material: PET
  • Cell window material: PET
  • Required sample amount for quantitative analysis: Approximately 8 mL (water base)
  • Keep cell window clean to avoid any contamination. Otherwise, It will cause inaccurate and wrong result.
  • Store cell windows and sample cells under dust-free condition. Be careful about metallic dusts especially. It might cause pin holes in the cell window and it results in a liquid leakage accident.
  • Volatile sample should not be placed in a full-sealed sample cell (disposable sample cell, a PET cell). Otherwise, the inner vapor pressure get increased in a sample cell beucase of the X-ray beam heat, and it may cause the burst of a film and it results in sample leakage accident.
  • Corrosive vapor from a sample might cause corrosion and damage to the analyzer.
  • Make sure that no liquid leakage occurs from a cell before placing it on the sample loading position of the analyzer.
  • Take out a cell from the sample loading position of the analyzer soon after a measurement is done. If you leave it for long time, it might cause liquid leakage accident.
  • Disassemble a cell soon after a measurement.
  • The specifications, appearance or other aspects of the pars in the webpage are subject to change without notice.

Please refer the detailed information in an instrumction manual which comes with the analyzer.