APCA-370

Ambient Carbon Dioxide Monitor

The APCA-370 is a device for continuous CO2 monitoring in ambient air. It uses cross modulation type non-dispersive infrared (NDIR) absorption method. This method employes one cell and one light source for both sample gas and reference gas what allows precise measurement without generation of zero-drift. Due to precise measurement and long term stability in continuous monitoring as well as its minimal maintenance requirements, this method has been a preferred method for monitoring the atmospheric pollution.

  • High precision and accuracy in long term
  • Exceptionally low drift by a combination of cross flow modulation and infrared-absorption technology
  • No need for adjustment by optical alignment
  • HORIBA's unique internal reference gas purifier*, which generates CO2-free zero gas and enhances analyzer performance
    * U.S. Patent No. 9962647
ModelAmbient CO2 Monitor
Measurement targetCarbon dioxide (CO2) in ambient air
Measuring principleCross modulation type non-dispersive infrared absorption method
Range0 ppm to 500/1000 ppm
Minimum detection sensitivity0.5 ppm (2σ)
Reproducibility (repeating accuracy)±1.0% of the full scale
Linearity (readout error)±2.0%
Zero drift*±0.1 ppm/day  ±2.0 ppm/week
Span drift*±2.0% of the full scale/day  ±3.0% of the full scale/week
Response rate60 sec or shorter (T90 from the inlet)
Sample collection rateApproximately 0.7 L/min
DisplayMeasured value, alarm, time, alarm history, calibration history, etc.
AlarmsZero calibration, span calibration, etc.

*Ambient temperature change: within 5°C
 

Environmental Countermeasures

Air Quality Monitoring

HORIBA offers customer oriented tailor-made system solutions with its state-of-the-art analytical technologies and more than 50 years experience in ambient air market. As your true partner in environmental preservation, we deliver air quality monitoring, indoor air quality monitoring , clean room airborne molecular contamination monitoring , quality control and stationary emission monitoring by diluted stack gas monitoring.

Explore application
Ambient CO2 Monitor Brochure (version B)

Ambient CO2 Monitor Brochure (version B)

0.31 MBPDF
AP-370 series Air Pollution Monitor Brochure (version Ga)

AP-370 series Air Pollution Monitor Brochure (version Ga)

3.84 MBPDF
Ambient CO2 monitor APCA-370 Operation Manual (version B / March, 2021)

Ambient CO2 monitor APCA-370 Operation Manual (version B / March, 2021)

2.24 MBPDF
APCA-370 China RoHS ( December, 2021)

APCA-370 China RoHS ( December, 2021)

0.11 MBPDF
APCA-370 Safety Information ( November, 2021)

APCA-370 Safety Information ( November, 2021)

1.17 MBPDF
Ambient Monitor APXA-370 Series Analog Output Specifications for Connector Type (version A / April, 2019)

Ambient Monitor APXA-370 Series Analog Output Specifications for Connector Type (version A / April, 2019)

1.12 MBPDF
Ambient Monitor APXX-370 Series RS-232C Instruction Manual (version B / April, 2019)

Ambient Monitor APXX-370 Series RS-232C Instruction Manual (version B / April, 2019)

0.74 MBPDF
Safety manual (version D / April, 2019)

Safety manual (version D / April, 2019)

0.74 MBPDF
Ambient Monitor APXX-370 Series Compact Flash Memory Instruction Manual (version C / July, 2019)

Ambient Monitor APXX-370 Series Compact Flash Memory Instruction Manual (version C / July, 2019)

1.46 MBPDF
Product Line: Ambient
Manufacturing Company: HORIBA, Ltd.
Base product: AP-370 Series

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Non-Dispersive Infrared Spectroscopy (NDIR)