GA-370

Trace Gas Monitor

For monitoring quality control of manufactured high-purity gases at air separation and semiconductor plants

GA-370 provides constant, ultrahigh-sensitivity and high-precision monitoring of trace impurities (CO, CO2 and CH4) for quality control at gas manufacturing facilities.


Introduction and application of GA-370

Ultra-high Sensitive Measurements

  • A cross-flow modulation dual-beam non-dispersive infrared (NDIR) analyzer provides continuous and stable zero drift-free measurements.
  • Minimum detection limit (MDL) of 10ppb which can support applications where high accuracy measurements are required.

 

Measurement of trace impurities in a balance gas

  • Representative gases such as N2, O2, He, Ar, H2 and Air are supported.

 

Easy maintenance-free operation

  • Operator friendly screen menus simplify analyzer operation, calibration and measurements
  • No optical alignment ever required.
  • A touch color LCD display allows operators to view graphs of accumulated data.

 

Application

  • Trace Impurities Monitoring at Air Separation Plants

Air separation plant separates atmospheric air into its primary components oxygen (O2), nitrogen (N2), and argon (Ar) by distillation at cryogenic temperatures.

Separation of air is performed using the difference in the boiling points of each constituent gas in the distillation unit, but the air must be treated in the pre-purification unit (PPU) before getting into cryogenic distillation process. PPU is designed to remove water vapor, carbon dioxide (CO2), and other impurities contained in the air to ensure water and CO2 does not enter into the distillation unit, where it could cause plugging in the process and create the risk of explosion.

The HORIBA GA-370 Trace Gas Monitor is a useful tool for continuous monitoring of impurities that might be present in the separated gas for safety control. Also, it could be used for measurement of impurities (CO, CO2, CH4) in final product of O2, N2 and Ar for quality assurance.

Principle of Measurement

  • Cross-Modulation Dual-Beam Non-Dispersive Infrared Method

Cross-Modulation NDIR method uses a solenoid valve that switches at a fixed cycle (e.g., 1 Hz) to synchronously and alternately flow a sample gas and a reference gas into the one gas cell to obtain a modulated concentration signal of the gas to be measured.

In this method, when the sample gas and the reference gas are the same gases (zero point), no modulation signal is generated. Absence of mechanical parts such as a rotating sector enables long-term stable output signal.

In cross-modulation dual-beam NDIR method, the use of double beam (light source) and a double cell allows the sample gas and the reference gas to flow alternately into the two cells, the diaphragm of the condenser microphone inside the detector moves to the left and to the right, providing twice the amount of signal comparing with the method when using a rotating sector, thereby improving the SN ratio.

The graph shows the noise level of the cross-modulation dual-beam non-dispersive infrared method, which is extremely low and stable. Thus, even in the measurement of trace concentrations of impurities in high-purity gases, this zero-drift free method provides long-term stability and low noise level.


 

Related Applications

Monitoring of Impurity in Hydrogen Gas for FCV

Explore more 

▶ Hydrogen Quality Check for FCV at On-Site Hydrogen Station

 

 

Model GA-370
Gases measured CO, CO2, CH4
Bulk gases N2, O2, He, Ar, H2, Air
Number of measurement components 1 component or 2 components (specify a measuring balance gas)
Measuring principle Cross-flow modulation non-dispersive infrared (NDIR) absorption method
Measurement ranges 0 to 1/2/5/10 ppm
Lowest detection limit (2σ) 10 ppb
Repeatability ≤ ± 2% of full scale
Indication error ≤ ± 2% of full scale
Zero Drift ≤ ± 0.02 ppm/day, ≤ ± 0.03 ppm/week
Span Drift ≤ ± 2% of full scale/day, ≤ ± 2% of full scale/week
Response time (T90) 

≤ 180s

Gas flow rate Sample gas : approx. 3.5L/min, reference gas : approx. 3.5L/min, span gas: approx. 3.5L/min

Note: A delivery pressure of 50-100kPa is recommended for both sample and reference gas.

Analog output 

Max. 2 channels isolated output (2 components)

Select one from 0 to 1V, 0 to 10V, 0 to 16mA, 4 to 20mA or 0 to 20mA.

Current output : Allowable load resistance 750Ω or less

Installation conditionsAmbient temperature0 to 40°C
Ambient relative humidity≤85%
DustLess than environmental standard 
Vibration≤ 0.29m/s², at ≤ 100Hz 
External dimensions, weight 430(W) x 221(H) x 555(D) mm (excluding protrusions), approx. 18kg
Power supply 100 to 240V AC, ≤ ± 10% (max. voltage: 250V AC)
Power consumption Approx. 100VA
Test Gas Generation in Research and Testing Laboratories
Test Gas Generation in Research and Testing Laboratories
Low Concentration Gas Monitoring in Coal and Consumable Fuels
Low Concentration Gas Monitoring in Coal and Consumable Fuels

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

LU-4000 Series
More LU-4000 Series

POCl3 Auto Refill System

MU-2200
More MU-2200

Mixed Gas Generators MU Series

SEC-8000 F/D/E Series
More SEC-8000 F/D/E Series

High Temperature Digital Mass Flow Controller

TFH-01/47
More TFH-01/47

PTFE Filter/TFH membrane

TU Series
More TU Series

Test Gas Generation Systems

51 series
More 51 series

Explosion-proof Gas Analyzer

AP-370 series
More AP-370 series

Air Pollution Monitor

APCA-370
More APCA-370

Ambient Carbon Dioxide Monitor

APHA-370
More APHA-370

THC Analysator

APMA-370
More APMA-370

Ambient Carbon Monoxide Monitor

APNA-370
More APNA-370

Ambient NOx Monitor

APNA-370/CU-2
More APNA-370/CU-2

Ambient Ammonium Monitor

APOA-370
More APOA-370

Ambient Ozone Monitor

APSA-370
More APSA-370

Ambient Sulfur Dioxide Monitor

APSA-370/CU-1
More APSA-370/CU-1

Ambient Hydrogen Sulfide Monitor

AQMS
More AQMS

Ambient Air Quality Monitoring System

CEMS
More CEMS

Continuous Emission Monitoring System

ENDA-5000 series
More ENDA-5000 series

Stack Gas Analysis System

FTX-ONE-CL
More FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
More FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

GI-700 series
More GI-700 series

Stack Gas Analyzer

IR-300
More IR-300

Vapor Concentration Monitor

IR-400
More IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-1170HCLD
More MEXA-1170HCLD

Heated Type NOx Analyzer

MEXA-1170HFID
More MEXA-1170HFID

Heated Type THC Analyzer

MEXA-1170SX
More MEXA-1170SX

Motor Exhaust Gas Sulfur Analyzer

MEXA-1300R
More MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
More MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
More MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-FT
More MEXA-ONE-FT

FTIR Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
More MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
More OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE IRLAM Unit
More OBS-ONE IRLAM Unit

On-board Emissions Measurement System for NH3/N2O

PG-300 series
More PG-300 series

Portable Gas Analyzer

Process
More Process

Process Analyzer System

PX-375
More PX-375

Continuous Particulate Monitor with X-ray Fluorescence

TX-100
More TX-100

Tunable Laser Gas Analyzer

VA-5000 / VA-5000WM Series
More VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer

51 series
More 51 series

Explosion-proof Gas Analyzer

AP-370 series
More AP-370 series

Air Pollution Monitor

APCA-370
More APCA-370

Ambient Carbon Dioxide Monitor

APMA-370
More APMA-370

Ambient Carbon Monoxide Monitor

EMGA-920
More EMGA-920

Oxygen/Nitrogen Analyzer

EMGA-921
More EMGA-921

Hydrogen Analyzer

EMGA-930
More EMGA-930

Oxygen/Nitrogen/Hydrogen Analyzer

EMGA-Expert
More EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzers

EMGA-Pro
More EMGA-Pro

Oxygen/Nitrogen/Hydrogen Analyzers

EMIA-Expert
More EMIA-Expert

Carbon/Sulfur Analyzer

EMIA-Pro
More EMIA-Pro

Carbon/Sulfur Analyzer

EMIA-Step
More EMIA-Step

Carbon/Sulfur Analyzer

ENDA-5000 series
More ENDA-5000 series

Stack Gas Analysis System

GI-700 series
More GI-700 series

Stack Gas Analyzer

IR-300
More IR-300

Vapor Concentration Monitor

IR-400
More IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
More LO-300

Laser scanning Oil Film Detector

MEXA-1300R
More MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-584L
More MEXA-584L

Automotive Emission Analyzer

MEXA-ONE
More MEXA-ONE

Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
More OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE IRLAM Unit
More OBS-ONE IRLAM Unit

On-board Emissions Measurement System for NH3/N2O

OCMA-500
More OCMA-500

Oil Content Analyzer

OCMA-550
More OCMA-550

Oil Content Analyzer

PG-300 series
More PG-300 series

Portable Gas Analyzer

TX-100
More TX-100

Tunable Laser Gas Analyzer

VA-5000 / VA-5000WM Series
More VA-5000 / VA-5000WM Series

Multi-Component Gas Analyzer