HT-110

Total Organic Carbon Monitor

The continuous online TOC-Analyzer HT-110 is suitable for the measurement ot total organic carbons in Purified Water (PW), Water For Injection (WFI) and Highly Purified Water (HPW). The unit is operating according to USP 643. It is applicable for pharmaceutical and/or semiconductor manufacturing. The measuring principle is based on UV-Oxidation and measurement of the difference in conductivity. TOC concentration measurement (TOC concentration 500 ppbC or lower) is necessary to perform quality control according to GMP (Good Manufacturing Practice).

 

Abteilung: Process Water
Produktionsfirma: HORIBA Advanced Techno Co., Ltd.

 

  • UV-Oxidation and conductivity determination: This method eliminates the need for reagents and carrier gases. It delivers an accurate measurement at low concentrations, like for instance in WFI (Water For Injection) areas and reduces the cost of operation at the same time.
  • “Debubbler“ embedded: Bubbles in production systems often cause unstable readings in many instruments. The embedded “Debubbler“ eliminates the influence of air and guarantees a stable measurement.
  • Optional external ON/OFF control of contact input terminals.
  • Maintenance cycle: “ONLY ONCE PER YEAR“: Maintenance only consists of annual UV-lamp exchange and annual calibration.
  • Conforms to: United States Pharmacopeia: USP <643>.
  • Reference solutions for System Suitability Test (SST): 1,4 Benzoquinone and Sucrose
  • Choice of 3 installation methods: Possible to install on a pole, wall or desktop.

 

 

Product nameTotal organic carbon analyzer (TOC analyzer)
ModelHT-110
Measurement methodContinuous UV oxidation conductivity method
Measurement limit0 ppb to 1000 ppb
Measurement range0 ppb to 100/500/1000 ppb
RepeatabilityWithin ±2% of full scale
Display resolution0.1 ppb (0 ppb to 100 ppb/0 ppb to 500 ppb range)
1 ppb (0 ppb to 1000 ppb range)
Transmission outputNumber of output point: one
4 mA to 20 mA DC/0 V to 1 V DC (optional) insulated input/output
Maximum load resistance: 600 Ω (minimum load resistance 100 kΩ (when optionally selected))
Transmission output range: optional setting possible within measurement range
Output target: TOC concentration
Contact outputNumber of outputs: 2
Alarm contact output (RLY1)
Contact method: relay contact, SPDT (1c)
Contact capacity: 125 V 3 A AC/24 V 3 A DC (load resistance)
Contact function: upper/lower limit function (ON/OFF control)
Output target:
at TOC, temperature, conductivity:
C-NO contact is “closed” during operation, “open” during normal conditions
(including a POWER OFF state) *C-NO contact is reversed at hold, or error:
C-NO contact is “open” during operation (including a POWER OFF state),
“closed” during normal conditions *C-NO contact is reversed
Alarm contact output (RLY2)
Contact method: relay contact, SPST (1a)
Contact capacity: 125 V 3 A AC/24 V 3 A DC (load resistance)
Contact function: upper/lower limit function (ON/OFF control)
Output target: TOC concentration
Contact inputNumber of input point: 1
Non-voltage normal open (1a) signal input (open collector input possible)
Insulation-type input
Max. ON resistance: 50 Ω
Open-circuit voltage: 5 V DC
Max. short circuit current: 10 mA
An error will not be generated even if there is notification of no sample detection
immediately after receipt of the pure water device stop signal receiving
The hold operation during the contact input receiving.
Sample water conditionConductivity: less than 10 μS/cm (less than 2 μS/cm in 0 ppb to 100 ppb range)
Temperature: 5℃ to 99℃
Pressure: 0.03 MPa to 0.50 MPa,
Pressure fluctuation: within ±0.05 MPa (within the specified pressure range)
Flow rate: 20 mL/min to 200 mL/min
Environmental conditionsTemperature: 5℃ to 40℃
Relative humidity: less than 85%
InstallationInstall place: indoor
Display functionLCD (with a back light) TOC, conductivity, water temperature, alarm
Power100 V to 240 V AC ±10%, 50 Hz/60 Hz built-in fuse 250 V AC 3.15 A (T)
Power consumption80 VA (max.)
Outside dimension300 (W) × 400 (H) × 165 (D) mm
Mass13 kg
Concerned directivesCE markingEMC Directive: EN61326-2-3
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
FCC RuleFCC parts 15
Protection structureIP 43 (IEC60529, JIS C0920)
Pollution level 2 (IEC61010-1)

Informationsanfrage

Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten. * Diese Felder sind Pflichtfelder.

Related products

CS-100 Series
CS-100 Series

Stand-alone Type Chemical Concentration Monitor

CS-100F1 Series
CS-100F1 Series

Fiber Optic Type Chemical Solution Concentration Monitor

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-700
CS-700

High Precision, High Stability Chemical Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

EG-100
EG-100

Washwater Monitoring System

HD-960L
HD-960L

Dissolved Oxygen Monitor in Low Concentration

HD-960LR
HD-960LR

Dissolved oxygen concentration monitor series for semiconductor manufacturing

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW-GC(W)
HE-960RW-GC(W)

2-Channel Resistivity Meter

HF-960EM
HF-960EM

In-line Sensor & Auto Range Switching Concentration Monitor

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
HF-SP-CU

2-channel High Precision HF Concentration Monitor

HZ-960
HZ-960

Dissolved Ozone Monitor

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor

ICP Neo
ICP Neo

ICP Software

OPSA-150
OPSA-150

Organic Pollutant Monitor

SLIA-300
SLIA-300

Highly Sensitive Silica Monitor

SLIA-5000
SLIA-5000

SILICA ANALYZER

TOCADERO ONE
TOCADERO ONE

On-line TOC Analyzer

TPNA-500
TPNA-500

Automatic Total Nitrogen/Phosphorus Monitoring

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

UP-100
UP-100

Micro Volume pH Monitor

HD-200
HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-300
HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
HD-960L

Dissolved Oxygen Monitor in Low Concentration

HD-960LR
HD-960LR

Dissolved oxygen concentration monitor series for semiconductor manufacturing

HE-200C
HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
HE-480R(W)

Industrial resistivity meter

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount Type Resistivity Meter(Four-Wire Transmission, 2-channel)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-Channel Resistivity Meter

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
HF-SP-CU

2-channel High Precision HF Concentration Monitor

HO-200
HO-200

Field-installation Type ORP Meter (Four-Wire Transmission)

HO-300
HO-300

Field-installation Type ORP Meter (Two-Wire Transmission)

HO-480
HO-480

Panel-mount Type ORP Meter (Four-Wire Transmission)

HR-200
HR-200

Feild-installation Type Residual Chlorine Meter (Four-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)

Corporate