Deep Cooled Vacuum Ultra Violet Scientific Cameras
The new Syncerity VUV Camera features:
• High QE in VUV Range 58% @120 nm (no ARC)
• Attachable to High Vacuum Chamber with Viton® O-Ring, down to < 10-6 Torr
• TE-cooled to -50°C (Vacuum) or -30°C with N2 Purge Low Dark Current, Low Noise
“Typical” VUV Response*
Type A
Type B
*This data is reference data only and is not guaranteed.
*Cameras provided without window have no warranty on CCD and need special handling under N2
Q.E. | Standard Type-A | Special Type-B | Special Type-B |
---|---|---|---|
CCD pixel | 2048 x 70 | 2048 x 256 2048 x 512 | 1024 x 128 |
CCD pixel size | 14 x 14 µm | 12 x 12 µm | 24 x 24 µm |
CCD height | 1 mm | 3 mm / 6 mm | 3 mm |
CCD AR coating | Without AR coating for 115 nm - 200 nm With AR coating for 135 nm - 1100 nm | ||
Window | No window or with MgF2 window | ||
Flange | Special flange for vacuum chamber with Viton 0-ring (Standard Syncerity cap + MgF2 window is also available) |
CCD Sensor Format | 2048 × 70 |
Quantum Efficiency at 20 °C | See type A curve for VUV and UV-VIS QE responses |
Pixel Size | 14 μm × 14 μm |
Image Area | 28.7 mm × 0.98 mm; 100% fill factor |
Deep Thermoelectric Cooling | -50°C under vacuum (10-6 mbar) with +25°C ambient or -30°C under N2 purging |
Single Pixel Well Capacity | 50 000 e¯/pixel (minimum); 60 000 e¯/pixel (typical) |
Serial Register Full Well Capacity | 250 000 e¯/pixel (minimum) 500 000 e¯/pixel (typical output register saturation) |
Scan Rates | 45 kHz and 500 kHz |
Readout Noise (at 45 kHz and at -50 °C)*1 | 9 e– (typical) to 12 e¯ (maximum) |
Readout Noise (at 500 kHz and at -50 °C)*1 | 20 e- (Typical) to 25 e- (Maximum) |
Maximum Spectral Rate | 20 Hz at 45 kHz scan rate 189 Hz at 500 kHz scan rate |
Digitization | 16 bit ADC |
Dynamic Range (Typical for Single Pixel)*2 | 55 500:1 |
Non Linearity (Measured on Each Camera) | <0.15% (typical) at 45 kHz (0.4% maximum) <0.20% (typical) at 500 kHz (1% maximum) |
Dark Current at -50 °C*3 (Note that pixel size = 14 μm) | 0.05 e – /pixel/s (typical) |
Software-Adjustable Gains | 2,4 and 10 e-/count at –50°C |
Environmental Conditions |
|
Weight | 1.769 kg (3.90 lb) |
Dimensions | Refer to mechanical drawings |
Power Requirements AC-DC Power Supply (Provided) Recommendation for OEM Supplying Camera | 90- 264 Vac, 47 - 63 Hz
|
Minimum Computer Requirements: |
|
Specifications subject to change without notice
Footnotes:
2048 x 256 | 2048 x 512 | 1024 x 128 |
Power Interface: Connector Type: | PDP-40, Mini PWR DIN, 4-Position, STR Plug |
Camera Interface: Connector Type: | USB Standard Type B |
Sync I/O Connectors: Input Jack: Output Plug: | SMB TTL IN (EXT TRIG In) TTL OUT (SHUTTER Out) |
Clinical chemistry measurements are based on optical spectrometry for most of the blood molecules and also based on potentiometry for a few blood ions.
Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.
Long Focal Length Spectrometer
Process efficiency in Hematology
The Gold Standard : Perfect combination of intuitive use and innovative technologies
The Gold Standard of Veterinary Hematology Testing
Small, Convenient, Bench-Top Analyser with Excellent Analytical Performance for Efficient Patient Care
A Dedicated Workstation for a Powerful Management of your Workflow
Productivity and reliability
Productivity and reliability
In the heart of hematopoiesis
In the heart of hematopoiesis
High performance haematology analysis with integrated validation
An innovative design solution covering all needs of high throughput automated hematology platforms
High Resolution Monochromators
Double monochromator
Mid-Focal Length Imaging Spectrometers
Short Focal Length Imaging Spectrometers
Ideal for Electrophysiology researchers to quantitate light intensity out of a microscope
World exclusive concept: Simultaneous blood analysis + CRP measurement, along with data management
Reliabilty and accuracy
From routine to specific tests, perform them all on a single system.
Improve your Hematology Workflow
Improve your Hematology workflow
Be productive and flexible, create quality
Be productive and flexible, create quality
Open tube analysis with a dedicated workstation ensuring complete convenience and flexibility
How will you contribute to the reduction of antibiotic resistance?
Compact and reliable hematology platform including reticulocytes by fluorescence
Self contained PMT housing for quantitative spectroscopy and imaging low light measurements
Deep Cooled UV/Vis/NIR
Large choice of PMTs, solid state, photoelectric detectors for custom spectroscopy solutions
Software Control and Data Acquisition
Deep Cooled NIR Scientific Cameras
OEM CCD Camera
Short Focal Length Triple Grating Imaging Spectrographs
Vacuum Spectrometer - Vacuum High Resolution monochromators for the 100-1500 nm region
High Dynamic Range Mini-Spectrometer
High Speed Miniature CCD Spectrometer
Mastering the Analyzis Process to Deliver Reliable Results
Cost Effective Hematology Solution For Small Mid-Size Laboratories
Full Walk Away Hematology Solution for Small Mid-Size Laboratories