PoliSpectra® VS70 Dual & Quad

DUAL & QUAD CCD Mini-Spectrometer

VS7000 OEM Spectrometer with 2-4 simultaneous spectra acquisition

High Speed UV-VIS-NIR spectrometers with 2-4 fiber inputs

Available for OEM industrial applications

  • DUAL: UV-VIS (200–860 nm), VIS (380–750 nm), and UV-NIR (200–1050 nm)
  • QUAD: VIS (470-730 nm)
  • High-speed electronics (as fast as <1.5 msec readout time)
  • High throughput (f/2.3)
  • Ultra-low stray light with aberration correction holographic grating
  • Ideal for industrial low-light applications such as fluorescence, OES, absorbance, and reactance.
Segment: Scientific
Manufacturing Company: HORIBA Scientific
FeatureSpectroscopy Benefits for OEMs 2-4 channel multi-spectral instruments
Most popular UV-VIS-NIR rangeExcellent peak symmetry in a miniature grating spectrometer
High readout speedSub 1.5msec readout speed for 2-4 channels of 2048 pixels each
 DUAL-QUAD Spectra acquisition; Low noise; high linearity (raw) and linearity-correction
Back-illuminated linear CCDQE = 63% at 250 nm; 76% at 650 nm; 55% at 850 nm
High signal-to-noise ratio> 500:1 SNR and 10,000:1 Dynamic Range (uncooled CCD)
USB 2.0 high and full-speedStandard connection interfaces to PCs with 100% data integrity
Order-sorting filter & Cross-talkOSF eliminates second-order interference & sub 0.1% cross-talk (QUAD)
Windows® acquisition software & LabVIEW™ VIs and DLLs availableSoftware to integrate VS-7000 as an OEM component
Sturdy single-optic designExcellent light purity, with concave grating design
No moving parts or shutterExcellent reliability for OEM integration

 

Concave-grating mini-spectrometer for

  • UV-VIS (DUAL only)
  • VIS (DUAL & QUAD)
  • UV-NIR (DUAL only)

 

Applications

  • Ideal for industrial low-light applications such as fluorescence, OES, absorbance, and reflectance
  • Multi spectra simultaneous monitoring from 2-4 fiber optic inputs

 

Acquisition software included (LabVIEW™)

  • VIs and top-level code are provided for customization
  • Handles acquisition and signal-processing (smoothing, absorbance, transmittance, etc.)
  • Save data to Excel® or text file
  • On-board spectral calibration
  • Option to gain access to corrected linearity (done at factory for each chip)
  • On-board or software averaging and pixel-binning

 

No LabVIEW™ license is needed to run our acquisition software. LabVIEW™ license ver. 2011 required to edit our code. No code customization supported in price.

The VS7000-CCD DUAL and QUAD systems for industrial OEM applications use 2-4 VS70 optical engines optimized for UV-VIS or VIS or UV-NIR Multi-spectral Systems.

 

Spectral coverageUV-VIS (200–860 nm), 250 nm optimized grating, built-in order-sorting filter (DUAL only)
VIS (380–750 nm), VIS-blazed grating, built-in long-pass filter (DUAL)
VIS (470-730 nm), VIS-blazed grating, built-in long-pass filter (QUAD)
UV-NIR (200–1050 nm), dual-blaze grating, built-in order-sorting filter (DUAL)
Numerical aperturef/2.3
Stray light rejection & Cross-talkStray light: 0.02 (max) for UV-VIS configuration with 300 µm tall CCD, measured at 700 nm (measured with broad bandpass 510 nm filter, 75 µm slit-width) Cross-talk: 0.1% (max)
CCD detector Typical QEBack-illuminated CCD with low etaloning in NIR 65% peak QE in UV
Detector height Fiber-optic option300 µm CCD height standard (1000 µm optional) 200-400-600 µm dia., 1.5 m long fiber-optic (for 1 mm tall CCD, prefer 600-800 µm dia.)
Thermoelectric stabilizationNone. Dark current and CCD-pattern noise must be subtracted. User must switch off light source or install manual shutter in optical path.
Spectral resolution
Pixel resolution
Slit (factory configuration)
UV-VIS: 75 µm slit, 2048 pixels, 2.7 nm resolution;
0.33 nm/pixel (configuration with 300 µm tall CCD) 
Available slits: 12-25-37-50-62-75-100-125-150-200 µm (contact us for other gratings)
CCD full well
Raw non linearity
Factory corrected linearity
2 options: 250 or 350 ke
<1.5%
<0.4%
Dynamic rangeUp to 10,000:1
A/D converter16 bit, 2-3 MHz (pixel rate)
Typical dark current50 e-/pixel/sec at 20°C (room temp.)
Typical readout noise30-35 e RMS
Readout speed(1.3) ms; 890 (760) spectra/s with 0 ms exposure time with respectively 300 µm (1000 µm) CCD height (with fast CCD option)

Specifications, form factor, and spectrometer cover subject to change without notice.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

1000M Series
1000M Series

Long Focal Length Spectrometer

CP20 Series
CP20 Series

OEM miniature spectrograph

FHR Series
FHR Series

High Resolution Monochromators

Gemini 180
Gemini 180

Double monochromator

iHR Series
iHR Series

Mid-Focal Length Imaging Spectrometers

Lumetta compact spectrograph
Lumetta compact spectrograph

High Sensitivity Imaging Spectrograph

MicroHR Series
MicroHR Series

Short Focal Length Imaging Spectrometers

Mini CCT Plus
Mini CCT Plus

Mini Raman Spectrometer

Spectrometers - LIBS spectrometers
Spectrometers - LIBS spectrometers

Laser-induced Breakdown Spectroscopy (LIBS)