Large choice of PMTs, solid state, photoelectric detectors for custom spectroscopy solutions
HORIBA offers a comprehensive array of single point detectors for a wide variety of applications in spectroscopy and biomedical research. These are complete detectors including housings, power supplies and facility for cooling if necessary. Available on a stand-alone basis, or in conjunction with our monochromators and spectrographs these detectors allow you to configure a custom solution for your unique requirements. Many of our spectrographs have dual exit ports allowing you to have both a point detector for ultimate resolution and a multi-channel imaging spectrograph for high speed spectral acquisitions. HORIBA offers more choices and better specifications to ensure you can select the best components for your needs.
Photomultiplier Detectors | Detector Material | Wavelength Range (nm) | Active Area, mm | Dark Current (nA) | Cooling | Chopper & Lock-In or Modulated Source |
---|---|---|---|---|---|---|
PMT-928SC | Multialkali Photocathode | 185 to 900 | 8 x 24 | 3 | RT or TE | Not Required |
955 | Multialkali Photocathode | 160 to 900 | 8 x 24 | 3 | RT or TE | Not Required |
1527 | Bialkali Photocathode | 185 to 650 | 8 x 24 | 0.1 | RT or TE | Not Required |
2658 | InGaAs Photocathode | 185 to 1010 | 3 x 12 | 1 | TE | Not Required |
1 Dual detectors consist of a silicon detector on top of a NIR detector, where the Silicon transmits wavelengths above 1 μm
RT = Room Temperature
TE = Thermoelectric cooling
LN2 = Liquid nitrogen cooling
Solid State Detectors | Detector Material | Wavelength Range (μm) | Active Area, mm | Sensitivity (D*) | Cooling | Chopper & Lock-In or Modulated Source |
---|---|---|---|---|---|---|
DSS-S025A | Silicon (Si) | 0.20 to 1.10 | 2.5 mm Ǿ | 1.48E+14 | RT | Not Required |
DSS-S025T | Silicon (Si) | 0.20 to 1.00 | 2.5 mm Ǿ | 2.22E+14 | TE | Not Required |
DSS-IGA020A | Indium gallium arsenide (InGaAs) | 0.80 to 1.70 | 2 mm Ǿ | 3.54E+13 | RT | Not Required |
DSS-IGA020T | Indium gallium arsenide (InGaAs) | 0.80 to 1.65 | 2 mm Ǿ | 1.18E+14 | TE | Not Required |
DSS-IGA020L | Indium gallium arsenide (InGaAs) | 0.80 to 1.55 | 2 mm Ǿ | 1.77E+15 | LN2 | Not Required |
DSS-IGA(1-9)010T | InGaAs Extended | 1.00 to 2.05 | 1 mm Ǿ | 8.86E+12 | TE | Recommended |
DSS-IGA(1-9)010L | InGaAs Extended | 1.00 to 1.90 | 1 mm Ǿ | 4.43E+13 | LN2 | Recommended |
DSS-IGA(2-2)010T | InGaAs Extended | 1.20 to 2.40 | 1 mm Ǿ | 1.77E+12 | TE | Recommended |
DSS-IGA(2-2)010L | InGaAs Extended | 1.30 to 2.20 | 1 mm Ǿ | 8.86E+12 | LN2 | Recommended |
DSS-G020A | Germanium (Ge) | 0.80 to 1.80 | 2 mm Ǿ | 3.94E+12 | RT | Not Required |
DSS-G020T | Germanium (Ge) | 0.80 to 1.60 | 2 mm Ǿ | 3.54E+13 | TE | Not Required |
DSS-G020L | Germanium (Ge) | 0.80 to 1.50 | 2 mm Ǿ | 7.09E+14 | LN2 | Not Required |
DSS-PS020A | Lead sulfide (PbS) | 1.00 to 2.80 | 2 x 2 | 1.00E+12 | RT | Required |
DSS-PS020T | Lead sulfide (PbS) | 1.00 to 2.80 | 2 x 2 | 6.67E+12 | TE | Required |
DSS-PSE020A | Lead selenide (PbSe) | 1.00 to 4.50 | 2 x 2 | 2.00E+10 | RT | Required |
DSS-PSE020T | Lead selenide (PbSe) | 1.00 to 4.50 | 2 x 2 | 1.00E+11 | TE | Required |
MCT(5)020T | Mercury cadmium telluride (HgCdTe) | 1.00 to 5.00 | 2 x 2 | 1.00E+11 | TE | Required |
DSS-IS020L | Indium antimonide (InSb) | 1.00 to 5.40 | 2 mm Ǿ | 1.20E+11 | LN2 | Recommended |
DSS-MCT(14)-LN | Mercury cadmium telluride (HgCdTe) | 2.00 to 14.00 | 2 x 2 | 4.00E+11 | LN2 | Required |
DSS-MCT(20)-LN | Mercury cadmium telluride (HgCdTe) | 2.00 to 20.0 | 2 x 2 | 6.67E+10 | LN2 | Required |
1 Dual detectors consist of a silicon detector on top of a NIR detector, where the Silicon transmits wavelengths above 1 μm
RT = Room Temperature
TE = Thermoelectric cooling
LN2 = Liquid nitrogen cooling
Pyroelectric Detector | Detector Material | Wavelength Range (μm) | Active Area, mm | Sensitivity (D*) | Cooling | Chopper & Lock-In or Modulated Source |
---|---|---|---|---|---|---|
DSS-LT020A | Lithium tantalate (LiTaO3) | 2.00 to 16.00 | 2 mm Ǿ | 1.77E+09 | RT | Required |
1 Dual detectors consist of a silicon detector on top of a NIR detector, where the Silicon transmits wavelengths above 1 μm
RT = Room Temperature
TE = Thermoelectric cooling
LN2 = Liquid nitrogen cooling
Solid State Dual Detectors1 | Detector Material | Wavelength Range (μm) | Active Area, mm | Sensitivity (D*) Si / IR Material | Cooling | Chopper & Lock-In or Modulated Source |
---|---|---|---|---|---|---|
DSS-SG020A | Si over Ge | 0.20 to 1.80 | 2 mm Ǿ | 1.48E+14/2.36E+12 | RT | Recommended |
DSS-SG020T | Si over Ge | 0.20 to 1.60 | 2 mm Ǿ | 2.22E+14/2.13E+13 | TE | Recommended |
DSS-SIGA020A | Si over InGaAs | 0.20 to 1.70 | 2 mm Ǿ | 1.48E+14/2.13E+13 | RT | Recommended |
DSS-SIGA020T | Si over InGaAs | 0.20 to 1.65 | 2 mm Ǿ | 2.22E+14/7.09E+13 | TE | Recommended |
DSS-SIA020A | Si over InAs | 0.20 to 3.50 | 2 mm Ǿ | 1.48E+14/5.32E+9 | RT | Recommended |
DSS-SIA020T | Si over InAs | 0.20 to 3.40 | 2 mm Ǿ | 2.22E+14/1.06E+11 | TE | Required |
DSS-SPS020A | Si over PbS | 0.20 to 2.80 | 2 mm Ǿ | 1.48E+14/6.00E+11 | RT | Required |
DSS-SPS020T | Si over PbS | 0.20 to 2.80 | 2 mm Ǿ | 2.22E+14/4.00E+12 | TE | Required |
DSS-SPSE020A | Si over PbSe | 0.20 to 4.50 | 2 mm Ǿ | 1.48E+14/1.20E+10 | RT | Required |
DSS-SPSE020T | Si over PbSe | 0.20 to 4.50 | 2 mm Ǿ | 2.22E+14/6.00E+10 | TE | Required |
1 Dual detectors consist of a silicon detector on top of a NIR detector, where the Silicon transmits wavelengths above 1 μm
RT = Room Temperature
TE = Thermoelectric cooling
LN2 = Liquid nitrogen cooling
A variety of ambient and cooled PMT housings are available for both stand-alone use and for efficient optical coupling with HORIBA spectrometers.
Housing | Application | Integrated | Cooling |
---|---|---|---|
1424M(S) | Spectrometer coupling | No | Ambient |
DPM-HVH(G) | Spectrometer coupling | Yes | Ambient |
OB-3004 | Stand-alone | Yes | Ambient |
1912F(G)-H | Spectrometer coupling | No | TE water cooling ΔT >40°C |
OB-3001 | Spectrometer coupling | No | TE air cooling -20°C |
Various optical couplers are available for collection of signal from HORIBA spectrometers to DSS solid state detectors. Dual detector housings enable mounting of up to 4 detectors on a single HORIBA spectrometer with two exit ports!
Coupler | Detector Compatibility | Chopper or Filter Wheel |
---|---|---|
1427C(-AU) | Single DSS Detector (ambient, TE, LN2) | N/A |
J23075610 | Single DSS Detector (ambient, TE, LN2) | Chopper |
J23075620 | Single DSS Detector (ambient, TE, LN2) | Filter Wheel |
J23075630 | Single DSS Detector (ambient, TE, LN2) | Chopper / Filter Wheel |
J23078370 | Two DSS Detectors (ambient, TE, LN2) | N/A |
J23079050 | PMT or DSS Detector (ambient, TE) and DSS Detector (ambient, TE, LN2) | N/A |
Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.
Mid-Focal Length Imaging Spectrometers
Long Focal Length Spectrometer
Hematology Analyzer
Hematology Analyzer
Hematology Analyzer
Hematology Analyzer
Hematology Analyzer
High Resolution Monochromators
Double monochromator
Mid-Focal Length Imaging Spectrometers
Short Focal Length Imaging Spectrometers
Ideal for Electrophysiology researchers to quantitate light intensity out of a microscope
Hematology Analyzer
Hematology Analyzer
Clinical Chemistry Analyzer
Clinical Chemistry Analyzer
Hematology Analyzer
Hematology Analyzer
Self contained PMT housing for quantitative spectroscopy and imaging low light measurements
Deep Cooled UV/Vis/NIR
Software Control and Data Acquisition
EMCCD Scientific Camera
Deep Cooled NIR Scientific Cameras
OEM CCD Camera
Deep Cooled Vacuum Ultra Violet Scientific Cameras
Short Focal Length Triple Grating Imaging Spectrographs
Clinical Chemisty Analyzer
Hematology Analyzer
Hematology Analyzer
Hematology Analyzer