FLIMera

FLIMera

SPAD array imaging camera for dynamic FLIM studies at real time video rates

A New Concept in FLIM Imaging

The HORIBA FLIMera camera is a new concept in FLIM technology. It is a wide field imaging camera, rather than a confocal point scanning system, with the intrinsic benefit of being able to study FLIM dynamics at video rates with a simple camera technology.

FLIMera Video (1:43)

Segment: Scientific
Fabricant: HORIBA Scientific
  • TCSPC per pixel architecture offers 24,576 simultaneous decays
  • Complex multicomponent lifetimes
  • Decay kinetics are acquired directly.
  • Sample analysis with up to 5 exponential decays
  • EzTime Image simple and efficient software interface
  • Perfect for complex and sophisticated molecular analysis like live cell dynamics and detection of biomarkers for disease diagnostics.

 

Advances in CMOS technology have led to the development of imaging sensors, based on arrays of pixels, with each pixel containing a single-photon avalanche photodiode (SPAD) and its associated timing electronics, based on a time to digital converter (TDC).

This enables rapid (video rate) fluorescence lifetime determination based on the time-correlated single photon counting technique (TCSPC) realized independently in each pixel (Figure 1).

Figure 1: The SPAD and TDC couple

A 192 x 128 pixel image sensor, implemented in 40 nm CMOS technology, is incorporated in a widefield epifluorescence microscope set-up. The sensor has a 13% fill-factor and each 18.4 x 9.2 μm pixel contains a TDC with a resolution <40 ps. This enables up to 24,576 simultaneous fluorescence lifetime measurements each with 4,096 time bins. Through dedicated firmware and the HORIBA EzTime Image software implementation, the fluorescence intensity and the average lifetime as well as the phasor plot generated from the TCSPC imaging measurement, can be simultaneously displayed in real time at video (>30 fps) rates (Figure 2).

Figure 2: Four simultaneous datasets presented

 

Modes of operation

The FLIMera is designed for use with HORIBA’s highly intuitive EzTime Image software. This software is used for FLIMera control, data acquisition and analysis. FLIMera provides 4 modes of operation.

  • Manual – User start and stop of acquisition, providing TCSPC intensity image and FLIM data for lifetime analysis.
  • Timed – User defined run time for acquisition, providing TCSPC intensity image and FLIM data for lifetime analysis.
  • Streaming to HDF5 file – TCSPC data can be streamed, for a user-determined time period, to a HDF5 file. This contains full records for each photon in every pixel, so no data is lost, and can be used to reconstruct frames for full decay analysis.
  • Phasor Plot – Complementing the histogram representation is the ability to show and select lifetime data in the form of a phasor plot in real time, as seen in Figure 3. The phasor plot requires initial calibration using a lifetime standard.

 

Figure 3: Phasor plot

 

The video-rate capability is demonstrated using standard samples and FUN-1 labelled yeast cells (Figure 4).


Figure 4: Sequence of images extracted from FUN-1 labeled yeast cell lifetime video https://youtu.be/1Fu7VOCsHuA

 

Figure 5 a: Decay from DeltaFLEX cuvette system

 

Figure 5 b: Decay from just one of 24,578 SPAD pixels demonstrates the very high resolution and TCSPC fidelity of FLIMera

FLIM and HORIBA

The novelty of the in-pixel detection and timing technology enables a widefield imaging approach, which significantly reduces data acquisition times enabling the study of dynamic events. FLIMera contributes to HORIBA’s long history in the field of fluorescence measurement; recognized by winning the prestigious Institute of Physics Business Innovation Award.

 

FLIMera Camera Specifications
ModalityWidefield Time-Domain TCSPC
SensorSPAD CMOS with In-Pixel TDC
Sensor Wavelength Range400 to 900 nm
Max Total Count RateUp to 295 Mcps theoretical
Max Pixel Count Rate12 kcps
Image Array192 x 128 pixels
Frame Rate (Max.)30 fps
Fill Factor13%
Lifetime RangeFrom 200 ps to 20 ns
Lifetime ResolutionUp to 4096 time bins of 50 ps
Connection TypeC-Mount
Electronics Interface IncludedHORIBA FLIMera Base Unit (includes laser synch input TTL)
Software IncludedHORIBA EzTime Image
Required ComponentsPulsed laser source
Light Source OptionsDeltaDiode Lasers

     

     

    FLASH-FLIM measurements with the FLIMera TCSPC Camera
    FLASH-FLIM measurements with the FLIMera TCSPC Camera
    Recent developments CMOS technology allow widefield lifetime imaging, with the ability to measure FLIM in real time, to be employed to investigate mobile samples and kinetics, as well as remote imaging.

    Request for Information

    Do you have any questions or requests? Use this form to contact our specialists.

    * These fields are mandatory.

    Related products

    Aqualog - Water Treatment Plant Analyzer
    Aqualog - Water Treatment Plant Analyzer

    Automated Organic Analysis & Early Warning Sentinel

    Aqualog Datastream
    Aqualog Datastream

    For Instant Water Quality Reports

    CFD-2G
    CFD-2G

    Amplifier-Discriminator

    DAS6
    DAS6

    Decay Analysis Software

    DeltaDiode
    DeltaDiode

    TCSPC Pulsed Sources

    DeltaFlex
    DeltaFlex

    TCSPC/MCS Fluorescence Lifetime System

    DeltaPro
    DeltaPro

    TCSPC Lifetime Fluorometer

    Duetta
    Duetta

    Fluorescence and Absorbance Spectrometer

    Fluorolog-QM
    Fluorolog-QM

    Modular Research Fluorometer for Lifetime and Steady State Measurements

    FluoroMax Plus
    FluoroMax Plus

    Steady State and Lifetime Benchtop Spectrofluorometer

    Hybrid Picosecond Photon Detector (HPPD) Series
    Hybrid Picosecond Photon Detector (HPPD) Series

    HORIBA’s latest development in TCSPC detector technology

    Nanolog
    Nanolog

    Steady State and Lifetime Nanotechnology EEM Spectrofluorometer

    Nanosizer
    Nanosizer

    For Single‐Walled Carbon Nanotube Excitation‐Emission Map Simulation and Analysis

    PPD Photon Counting Detector
    PPD Photon Counting Detector

    Single photons detection with picosecond accuracy

    QuantaPhi-2
    QuantaPhi-2

    PLQY Integrating Sphere

    SpectraLED
    SpectraLED

    LED Phosphorescence Light Sources

    Universal Fiber Coupling Solution
    Universal Fiber Coupling Solution

    Connect any of our steady state and hybrid fluorometers to virtually any upright or inverted microscope!

    Corporate