PM-960, PM-100

PM-960

Peracetic acid concentration monitor

Continuous measurement of peracetic acid concentration for food filling machines.

PM-960 / PM-100 are measurement devices used to continuously measure the concentration of peracetic acid, which is utilized for sterilization in beverage and food processing. Reagents are not required and maintenance is easy.

PAA

Division: Process Water
Fabricant: HORIBA Advanced Techno Co., Ltd.

Compatible with a wide range of measurement

Measurements of concentrations ranging from 100 to 4000 ppm are possible.

Continuous measurement is possible

Continuous measurement of concentration becomes possible when the sample water is supplied at a constant flow rate of 500-2000 mL/min and a pressure below 0.1 MPa.

High maintainability

Sensor replacement is simple. From sensor replacement to calibration, intuitive operation is possible. No reagents are required.

Remote operation is possible

Operation from a remote location using a panel-mounted display unit is possible. Equipped with a 4-20mA output and RS-485 communication, it has 5 contact outputs.

Converter

Product nameConverter for peracetic acid monitor※1
ModelPM-960
Temperature compensation elementPlatinum resistance thermometer (Pt1000) 1000 W at 0℃, 3850 ppm/℃
Measurement range100 to 4000ppm (0.010 to 0.400%)
Repeatability±100ppm
Transmission outputNumber of outputs: 2 (Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.) 4mA to 20mA DC or 0mA to 20mA DC input/output isolated type Load resistance: 900  (max.) Linearity: Within 0.08 mA (Output only) Repeatability: Within 0.02 mA (Output only) Output setting: Peracetic acid concentration (Selectable from 0 to 22000 ppm or 0.000 to 2.200) Temperature (Selectable from 10C to 110C) HOLD function: Selectable from the previous value hold and the optional value hold (Setable without HOLD only while calibration
Contact outputNumber of outputs: 5 Contact output: 4 (R1 to R4) Contact type: Non-voltage contact output, relay contact SPST (1a) Contact capacity: 240 V AC 1 A, 30 V DC 1 A (Resistance load) Contact function: Selectable from Upper/lower limit alarm (ON/OFF control) at each measuring objects(concentration, temperature) (Alarm Setting of delay time about measuring objects: 0 seconds to 600 seconds) Contact action: closed when status is in the event. (However, R1 to R3 share a common terminal. R4 and RF share a common terminal) Error alarm contact output (RF): 1 Contact type: Non-voltage contact output, Relay contact, SPDT (1c) Contact capacity: 240 V AC 1 A, 30 V DC 1 A (Resistance load) Contact function: Fail Contact action: Closed when status is normal for C-NO output. Opened when any erroneous status is detected or power is down for C-NO output. C-NC output is opposite action of C-NO. R4 and RF share a common terminal.
Contact inputNumber of input: 1 (external HOLD input) Contact type: No-voltage a contact for open collector Condition: ON resistance: 100 ・ (max.)
・Open-circuit voltage: 24 V DC
・Short-circuit current: 12 mA DC (max.)
Communication outputRS-485 input/output
Self-diagnosis functionCalibration error /Temperture sensor error/Meter error
Power supply24 V DC ±10%
StructureIndoor-use panel installation type Panel case: ABS, Terminal: PBT Panel: IP65 dust and water proof structure
Conforming standardsCE Marking EMC Directive: EN61326-1※2 Class A, Industrial electromagnetic environment FCC rule FCC Part15

Sensor

Product namePeracetic acid sensor※3
Model5800
Measurement principleElectrochemical measurement system
Measurement targetPeracetic acid (CH3COOOH) ※4
Sample temperature range0℃to 45℃ (without freezing)
Supply flow rate500 mL/min to 2000 mL/min※5
PressureWithin 0.1 MPa (constant)※6
Responsibility(To the measurement cell after a supply start) T90 < 5 min※5
Repeatability±100 ppm※7
Ambient temperature0℃ to 45
Liquid contact materialPVC, PTFE, Silicon, PPO, OPP
Internal liquidNeutral phosphate(Food additive)
Cable length5 m to 50 m max.※8

※1 This product does not use for medical equipment.
※2 When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.
※3 This product does not use for medical equipment.
※4 Measurements may be affected by a change of the concentrations of hydrogen peroxide
※5 When supply flow rate decreases, responsibility may become slow. Supply flow rate is responsibility when switches from the solution including peracetic acid from the solution which does not include peracetic acid.
※6 When sample pressure includes a change, influence is reflected on instructions level. Install it to become the constant pressure.
※7 Under the constant ambient temperature, sample temperature and flow rate
※8 When the connection cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

 

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HF-700A
HF-700A

Low Concentration Monitor- Sulfuric Acid/Hydrogen Peroxide

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HO-480
HO-480

Panel-mount type ORP meter

HR-200
HR-200

Field-installation type polarographic residual chlorine meter

HR-200RT
HR-200RT

Field-installation type residual chlorine meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

HT-110
HT-110

On-line TOC analyzer

Corporate