Synapse EM Camera

EMCCD for low-light and ultrafast spectroscopy

UV-VIS-NIR EMCCDs Camera

EMCCD Camera for OEM Industrial Applications

Key Applications

  • Raman spectroscopy
  • SERS, TERS
  • Multi-track spectroscopy
  • Transient spectroscopy
  • Single-molecule spectroscopy
Segment: Scientific
Fabricant: HORIBA Scientific

Key Features and Benefits

  • 1600 × 200 or 1600 × 400 EMCCD sensor  - 16 × 16 μm pixel size for high spectral resolution
  • 25.6 × 3.2 mm or 25.6 × 6.4 mm image area  - Ideal for high-speed or multi-track spectroscopy
  • Back- and front-illuminated - BIQX Technology with enhanced QE below 450 nm 
  • Deep thermoelectric cooling  - Air or liquid circulation to minimize dark current
  • Dual readout modes  - EMCCD or CCD for a broad range of light conditions
  • Readout rates up to 3 MHz  - Acquires more than 1600 spectra per second
  • Single fused-silica vacuum window  - Minimizes reflection losses from UV to near-IR

 

 

SensorFront-illuminated (FI), back-illuminated (BI), scientific grade 1 
Active pixels1600 × 2001600 × 400
Pixel size16 μm × 16 μm
Image area25.6 mm × 3.2 mm25.6 mm × 6.4 mm
Output node well capacity
      High Sensitivity mode
      Electron Multiplying mode
300,000 e—
1,300,000 e—
Register Well Depth
      High Sensitivity mode
      Electron Multiplying mode
450,000 e—
800,000 e—
Non-linearity
(measured at all speeds per camera)
< 0.75%
Readout Noise (e—):  Typ. (Max)
      High Sensitivity mode:        EM off
      Electron Multiplying mode: EM off
      Electron Multiplying mode: EM on
50 kHz                    1 MHz                    3 MHz
2.7 (5)                     6.1 (9)                    8.5 (12)
8.0 (15)                     23 (35)                    38 (50)
< 1                         < 1                        < 1
Dark Current at —60°C (e—/pixel/s)
      FI
      BI
< 0.002
< 0.01
Maximum spectra per second
      Full vertical bin
      ROI mode 20 rows
      ROI mode 8 rows
616
1475
1613
376
1475
1613
Software-adjustable gain (e—/count)
      High Sensitivity mode
      Electron Multiplying mode
Selectable from 0.6 to 4.0
Selectable from 3.6 to 25
Electron multiplier gain1 to 1000, software-controlled
Digitization16-bit ADC
Vertical shift rates4.9, 9.6, 19 software-selectable(4)
Cooling at +20°C
      Air-cooled
      Liquid-cooling recirculator
—60°C (guaranteed)
—75°C (typical)
Power requirements
      AC-DC power supply (provided)
AC input 90–264 VAC, 47–63 Hz
DC output +9 V, 6.44 A maximum

 

(1) Region Of Interest (ROI) mode 8 rows
(2) Measured at -60°C
(3) Measured at all read-out speeds for each camera
(4) Some decrease in CTE may be observed at faster speeds.

 

 

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Corporate