VS70-PDA-HDR

Miniature 18-Bit Spectrometer

Introducing HORIBA’s VS70-PDA-HDR OEM Photodiode Array Spectrometer…a high-performance USB 2.0 powered compact fiber-coupled spectrometer covering a wide spectral range of 200 to 1000 nm with 18-bit digital resolution.

Based on an enhanced VS70 optical engine and a newly designed, monolithic single board ultra-quiet 18-bit data acquisition system, this “smart” spectrometer system boasts a dynamic range of more than 42,000:1 for industrial, bright-light applications such as emission, absorbance and reflectance.

At the optical heart of this VS70-PDA-HDR lies a proprietary HORIBA type-IV Aberration-corrected Flat-field Holographic Ion-etched concave grating and custom order-sorting filter to eliminate higher diffraction orders.

In addition to the instrument’s single-optics design that provides sterling performance attributes with respect to imaging, sensitivity, resolution and low stray light, this detection system offers flexible I/O triggering for experiment synchronization, as well as a highly efficient USB-powered architecture.

For OEM Industrial Applications

Ideal for industrial bright-light applications such as emission, absorbance, differential optical absorbance, and reflectance.

Examples:

  • Pharmaceuticals & life science
  • Hematology
  • HPLC/UPLC
  • Semiconductor
  • Environment, agriculture and energy

 

Available in select countries.

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

Segment: Scientific
Fabricant: HORIBA Scientific
  • High spectral acquisition speed (readout time ~5 ms/1024 pixels)
  • Wide spectral coverage from UV to NIR
  • Colossal PDA full well up to 1 Ge, more than 100 times deeper than any CCD
  • High signal-to-noise ratio combined with ultra low stray light, 18-bit digital resolution
  • High UV sensitivity with smoothly varying spectral response
  • High throughput
  • Compact size, robustness and high thermal stability

 

 

View and Download our OEM Spectrometer Selection Guide

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

General Spectrometer Specifications*
Spectral CoverageUV-VIS (200–800 nm) with 477 l/mm grating, VIS (280--700 nm) with 582 l/mm grating,
UV-NIR (200–985 nm) with double blazed 365 l/mm grating.
On request, other spectral ranges available; different mechanical integration might be needed
Spectrometer InputFiber-coupled: FC or SMA; Free space: 12-25-37-50-62-75-100-125-150-200 μm slits;
Other options available upon request
Spectral Resolution2 nm for 365 l/mm grating, 1 nm for 477 l/mm grating, 0.8 nm for 582 l/mm grating
(25 μm slit for all)
Average Spectral Dispersion30.9 nm/mm for 365 l/mm grating, 23.7 nm/mm for 477 l/mm grating
16.3 nm/mm for 582 l/mm grating
Average Digital Resolution with 25 (50) μm pixel width0.8 (1.5) nm/px for 365 l/mm grating, 0.59 (1.2) nm/px for 477 l/mm grating,
0.4 (0.8) nm/px for 582 l/mm grating
Focal Length70 mm
OptionsSelection of high grade sensors: Hamamatsu® S1590x and S1012x families (other PDA
sensors available upon request); Input port: SMA, FC, free space, custom input
(e.g., round-to-line fiber bundle)
F/#F/2.8
Stray Light Rejection Typical0.01% for UV-VIS configuration measured at 400 nm and 700 nm with a 550 nm
(40 nm band) bandpass filter, 31 μm slit-width
Wavelength Accuracy0.2 nm
Software**LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)

 

Detector Options and Specifications*

 OPTION A (High SNR, High Spectral Resolution)
Detector ModelHamamatsu S10124-1024 o r S15909-1024 with high UV sensitivity.
Sensor Format1024 x 1 pixels
PDA Pixel Size25 μm x 2500 μm
PDA Active Area25.6 mm x 2.5 mm
PDA Spectral ResponseS15909-1024 has improved spectral response (NO FRINGES) compared to S10124-1024.
(See figure below)
Sensor TemperatureUncooled
Full Well Capacity624 Me- for S15909-1024 and 468 Me- for S10124-1024
Readout Noise14,700 e- (typical) for S15909-1024. S10124-1024 not yet evaluated
Digitization18-bit
Dynamic Range (FW/RN)42,500:1 (typical) for S15909-1024. S10124-1024 not yet evaluated
Max SNR (√FW)24,980:1 (typical) for S15909-1024 and 21,600:1 (typical) for S10124-1024
Non-linearity (measured on each system)< 0.4% (corrected)
Dark Current (at 25C ambient)190,000 e-/pix/s (typical) for S15909-1024 and 625,000 e-/pixel/s (typical) for S10124-1024
CommunicationUSB 2.0 High-speed, (USB 3.0 customizable)
Environmental ConditionsOperating temperature 15° C to 40° C ambient
Relative humidity <70% (non-condensing)
Storage temperature -25° C to 45° C
Power Requirements5 VDC @ 0.13 A, USB-powered or Molex connector
 OPTION B (High SNR, Medium Spectral Resolution)
Detector ModelHamamatsu S15908-512 or S10121-512 with high UV sensitivity.
Sensor Format512 x 1 pixels
PDA Pixel Size50 μm x 2500 μm
PDA Active Area25.6 mm x 2.5 mm
PDA QES15908-512 has improved spectral response (NO FRINGES) compared to S10121-512.
(See figure below)
Sensor TemperatureUncooled
Full Well Capacity1.25 Ge- for S15908-512 and 1.03 Ge- for S10121-512
Readout Noise14,700 e- (typical)
Digitization18-bit
Dynamic Range (FW/RN)42,500:1 (typical)
SNR24,000:1 (typical)
Non-linearity (measured on each system)< 0.4% (corrected)
Dark Current190,000 e-/pix/s (typical)
CommunicationUSB 2.0 High-speed, (USB 3.0 customizable)
Environmental ConditionsOperating temperature 15° C to 40° C ambient
Relative humidity <70% (non-condensing)
Storage temperature -25° C to 45° C
Power Requirements5 VDC @ 0.13 A, USB-powered or Molex connector
 OPTION C (Medium SNR, High Spectral Resolution)
Detector ModelHamamatsu S10123-1024 with high UV sensitivity
Sensor Format1024 x 1 pixels
PDA Pixel Size25 μm x 500 μm
PDA Active Area25.6 mm x 0.5 mm
PDA QE(See figure below)
Sensor TemperatureUncooled
Full Well Capacity87 Me-
Readout Noise14,700 e- (typical)
Digitization18-bit
Dynamic Range (FW/RN)Not yet evaluated.
SNR9,330:1 (typical)
Non-linearity (measured on each system)< 0.4% (corrected)
Dark Current125,000 e-/pix/s (typical)
CommunicationUSB 2.0 High-speed, (USB 3.0 customizable)
Environmental ConditionsOperating temperature 15° C to 40° C ambient
Relative humidity <70% (non-condensing)
Storage temperature -25° C to 45° C
Power Requirements5 VDC @ 0.13 A, USB-powered or Molex connector
 OPTION D (Medium SNR, Medium Spectral Resolution)
Detector ModelHamamatsu S10121-512 with high UV sensitivity.
Sensor Format512 x 1 pixels
PDA Pixel Size50 μm x 500 μm
PDA Active Area25.6 mm x 0.5 mm
PDA QE(See figure below)
Sensor TemperatureUncooled
Full Well Capacity200 Me-
Readout Noise14,700 e- (typical)
Digitization18-bit
Dynamic Range (FW/RN)Not yet evaluated.
SNRNot yet evaluated.
Non-linearity (measured on each system)< 0.4% (corrected)
Dark Current125,000 e-/pix/s (typical)
CommunicationUSB 2.0 High-speed, (USB 3.0 customizable)
Environmental ConditionsOperating temperature 15° C to 40° C ambient
Relative humidity <70% (non-condensing)
Storage temperature -25° C to 45° C
Power Requirements5 VDC @ 0.13 A, USB-powered or Molex connector

* HORIBA Instruments has a policy of continuous product development, and reserves the right to amend part numbers, descriptions and
specifications without prior notice.
**No LabVIEW™ license is needed to run our acquisition software.

 