Ammonia Nitrogen Meter
HC-200NH is an ammonia nitrogen(NH4-N) meter using ion electrode method which is designed for aeration control in wastewater treatment.
*1: patent applied with Bureau of Sewerage Tokyo Metropolitan Government.
*2: patent applied
Model | HC-200NH |
---|
Combination sensor unit model | AM-2000 |
---|---|
Sensor model | 7691*: Ammonium ion chip, 7692*: Potassium ion chip for compensation, 7211: Reference chip |
Measurement range | NH4-N: 0~1000mg/L (display range: 0~2000mg/L) Temperature: 0~40°C (display range: -10~110°C) |
Display resolution | NH4-N: 0.01mg/L: 0.00~10.00mg/L 0.1mg/L: 0.0~100.0mg/L 1mg/L: 0~1000mg/L Temperature: 0.1°C |
Repeatability | NH4-N: Larger value between 3%±1 digit of measured value or 0.2mg/L±1 digit (with standard solution) Temperature: ±0.3°C |
Potassium ion compensation | Compensation range: Potassium ion concentration is under 10 times of ammonium ion concentration and under 1000mg/L Compensation error: ±20% (measured value) |
Additional function | Adjustment with manual analysis (1 point), calibration curve input function (primary expression) |
Self-diagnostic function | Correction error, sensor diagnostic error, transmitter malfunction |
*Sensor7691 and 7692 : Store in low temperature (1〜30°C)
Combination sensor unit model | DO-2000 |
---|---|
Sensor model | 5700A: Sensor cap |
Measurement range | Dissolved oxygen concentration: 0~20mg/L Display resolution 0.01mg/L Saturation degree: 0~200% Display resolution 0.1% Temperature: 0~50°C Display resolution 0.1°C |
Self-diagnostic | Correction error, sensor diagnostic error, transmitter malfunction |
Transmission output | 3 points DC4~20mA input-output insulation type Maximum load resistance 900Ω Select 3 items from below Output range 1: Ammonia nitrogen concentration: Configurable within measurement range. Output range 2: Dissolved oxygen concentration: Configurable within measurement range. Output range 3: Temperature reading of the ammonia nitrogen meter: Configurable within measurement range of -10~110°C Output range 4: Temperature reading of the dissolved oxygen meter: Configurable within measurement range of -10〜110°C. |
---|---|
Operation temperature range | -20~55°C (Do not freeze) |
Power | AC100~240V 50/60Hz Consumption power 28VA (max) |
Structure | Outdoor installation type: Protection level IP65 Installation method: 50A pole or attached to wall Case: aluminum alloy Attachment bracket: Hood: SUS304 |
Weight | Unit: Approx. 3.5kg Hood, attachment bracket: Approx. 1kg |
Compliance standard | CE Marking, FCC Rules |
Sensor unit model | AM-2000 |
---|---|
Sample condition | 0~40°C, pH4.0~8.5 [Na+]: 0~1000 times of [NH4-N] |
Measurement depth | 10m |
Wetted material | SUS316, FKM, PVC |
Weight | Approx. 2.7kg (including 10m cable) |
Sensor unit model | DO-2000 |
---|---|
Measurement sample temperature | 0~50°C |
Measurement depth | 10m |
Wetted material | SUS316, NBR, PVC |
Weight | Approx. 3.0kg (including 10m cable) |
Schematics
Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.
For Instant Water Quality Reports
For Instant Water Quality Reports
Sanitary Conductivity Sensor (Flow Through type) for Low Concentrations
OEM gratings design and production capabilities
Carbon Sensor Conductivity Meter (Low concentration type)
Industrial resistivity meter