HD-300

Field-installation type dissolved oxygen meter (DO meter)

For control and management in wastewater treatment and production processes.

Ideal for the management of aeration tanks at facilities such as wastewater treatment plants and industrial wastewater treatment facilities. Featuring a low-cost membrane cap replacement system and safe inner liquids with KCl (potassium chloride).

DO

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Low-cost sensor replacement

For sensor replacement, only the membrane cap needs to be replaced, making it more cost-effective compared to replacing the sensor chip.

Safe inner liquid

Utilizing a safe KCl solution as the inner liquids.

Product nameDissolved oxygen meter
ModelHD-300
Combined sensor5505, 5510 (A bipolar diaphragm type polarography sensor)
Combined probeDO-1100
Measurement
range
Dissolved oxygen
concentration
0 mg/L to 20 mg/L (Display range: 0 mg/L to 22 mg/L)
Saturation degree0% to 200% (Display range: 0% to 200%)
Temperature0℃ to 50℃ (Display range: -10℃ to 110℃)
Display
resolution
Dissolved oxygen
concentration
0.01 mg/L
Saturation degree1%
Temperature0.1℃
PerformanceDissolved
oxygen
concentration
RepeatabilityWithin ±0.5% of the full scale (response for equivalent input)
LinearityWithin ±0.5% of the full scale (response for equivalent input)
TemperatureRepeatability±0.5℃ (response for equivalent input)
Linearity±0.5℃ (response for equivalent input)
Transmission
output
Output type4 mA to 20 mA DC: input/output isolated type
Load resistanceMaximum: 600 Ω(when power supply voltage is 24 V DC) (*1)
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeDissolved oxygen concentration: Selection from preset ranges or free range input within measuring range.
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact inputNumber of input points1
Contact typeNo-voltage a-contact
ConditionsON resistance: 40 Ω maximum.
Open voltage: 1.2 V DC
Short-circuit current: 21 mA DC
Contact functionExternal input for transmission holding.
Temperature
compensation
Applicable temperature
element
Platinum resistor: 1 kΩ (0℃)
(The temperature sensor is built into the probe DO-1000.)
Temperature compensation
range
0℃ to 50℃
Temperature calibration1 point calibration comparing to reference thermometer
CalibrationCalibration methodSpan calibration in the air or DO saturated aquaous solution
Number of calibration pointsAtmospheric calibration: 1 point
(Zero electric calibration is carried out automatically)
Saturation liquid calibration: 2 points (zero calibration is omitted)
Additional capabilitiesSalinity compensation (0.0% to 5.0%)
Automatic detection of calibration failure (Zero error, Sensitivity error)
Calibration history (Elapsed days from the last calibration which ever zero or span, zero shift, span sensitivity)
Self-checkCalibration errorZero calibration error, sensitivity error, outside of temperature calibration range
Electrode diagnostic errorSensor error (damage to diaphragm), disconnection of sensor (or damage to sealing), temperature sensor short-circuit, and electric discontinuity of temperature sensor
meter errorCPU error, CPU error, ADC error, memory error
Operating temperature range-20℃ to 60℃ (without freeze)
Operating humidity rangeRelative humidity: 5% to 90% (without condensation)
Storage temperature-25℃ to 65℃
Power supplyRated voltage24 V DC (operating voltage range: 21 V to 32 V DC)*1
Power consumption0.6 W max.
Compatible
standards
CE markingEMC  :EN61326-1
     Class A, Industrial electromagnetic environment
RoHS  :EN50581
     9. Industrial monitoring and control instruments
FCC rulesPart15 Class A
StructureInstallationOutdoor installation type
Installation methodAttached to 50A pole or wall
Protection codeIP65
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of hoodSUS304 (Epoxy degenerated melamine resin painting)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
MassMain body: Approx. 2.8 kg
Cover and mounting brackets: Approx. 1 kg

*1: The maximum load resistance that can be connected is decided depending on the power-supply voltage.

Relation between power supply voltage and load resistance

Note

An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

EMGA-921
EMGA-921

Hydrogen Analyzer

EMGA-Expert
EMGA-Expert

Oxygen/Nitrogen/Hydrogen Analyzer
(Flagship High-Accuracy Model)

EMGA-Pro
EMGA-Pro

Oxygen/Nitrogen Analyzer (Entry Model)

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HF-700A
HF-700A

Low Concentration Monitor- Sulfuric Acid/Hydrogen Peroxide

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HO-480
HO-480

Panel-mount type ORP meter

HR-200
HR-200

Field-installation type polarographic residual chlorine meter

HR-200RT
HR-200RT

Field-installation type residual chlorine meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

HT-110
HT-110

On-line TOC analyzer

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor