NOx | SO2 | CO | CO2 | O2 | CH4 | ||
---|---|---|---|---|---|---|---|
Standard | PG-320 |
| ● | ● | |||
PG-325 | ● | ● | |||||
PG-330 | ● | ● | ● | ||||
PG-335 | ● | ● | ● | ||||
PG-337 | ● | ● | ● | ||||
PG-340 | ● | ● | ● | ● | |||
PG-350 | ● | ● | ● | ● | ● | ||
CH4 | PG-324 | ● | ● | ||||
PG-344 | ● | ● | ● | ● |
Analysis Principle (Standard models) | |
---|---|
NOX | Cross-Flow Modulation Chemiluminescence Detection Method |
SO2 CO | Cross-Flow Modulation Non-Dispersive Infrared Absorption Method |
CO2 | Non-Dispersive Infrared Absorption Method |
O2 | Galvanic, Zirconia or Paramagnetic Method |
Analysis Principle (CH4 models) | |
---|---|
CH4,CO | Cross-Flow Modulation Non-Dispersive Infrared |
CH4,CO | Non-Dispersive Infrared Absorption Method |
CO2 | Non-Dispersive Infrared Absorption Method |
O2 | Galvanic, Zirconia or Paramagnetic Method |
Ranges (Standard models) | |
---|---|
NOX | A-range 0-25/50/100/250/500/1000/2500ppm(standard spec.) B-range 0-50/100/250/500/1000/2500/5000ppm |
SO2 | 0-200/500/1000ppm |
CO | A-range 0-200/500/1000/2000/5000ppm (standard spec.) B-range 0-0.5/1/5/10/15 vol% (B-range is not available for PG-350) |
CO2 | 0-5/10/20 vol% |
O2 | 0-5/10/25 vol%(Galvanic or Zirconia method) 0-10/25 vol%(Paramagnetic method) |
Ranges (CH4 models) | ||
---|---|---|
A-range | B- range | |
CH4 | 0-2000/5000ppm | 0-50/100vol% |
CO | 0-2000/5000ppm | 0-10/50vol% |
CO2 | 0-5/10/20vol% | 0-25/50/75vol% |
O2 | 0-5/10/25vol% (Galvanic or Zirconia method) 0-10/25vol% (Paramagnetic method) | 0-10/25vol% (Paramagnetic method) |
Standard Model | CH4 Model | |
---|---|---|
Repeatability | ±0.5% of full scale (NOx:≧100ppm range / CO: ≧1000ppm range) ±1.0% of full scale (Except above) | ±1.0% of full scale |
Linearity | ±2.0% of full scale | |
Drift | ±1.0% of full scale / day (For SO2 analyzer only: ±2.0% of full scale / day) | |
Response Time (T90) | Analyzers except SO2 analyzer: 45 sec. or less (From sample inlet) SO2 analyzer: 180 sec. or less (From sample inlet) | |
Sample Gas Flow Rate | Approx. 0.5L/min. (Approx. 1.0L/min for CH4 100% range) | |
Display | Measurement (3 or 4 digit display), range flow rate, etc. | |
Output | DC 4-20 mA (non-insulated) / Ethernet | |
Warm-up Time | 30 min. ±2.0% of full scale / 2 hours | |
Data Saving | SDTM memory card / SDHCTM memory card | |
Ambient Temperature | 0°C-40°C <32°F-104°F> | |
Ambient Humidity | 85% RH or less | |
Power | AC 100V to 240V, 50/60 Hz | |
Power Consumption | Approx. 160VA in a steady state, maximum 220VA | |
Dimentions | (With side guards) 300(W) x 520(D) x 260(H) mm <11.8"(W) x 20.5"(D) x 10.2"(H)> (Without side guards) 260(W) x 520(D) x 260(H) mm <10.2"(W) x 20.5"(D) x 10.2"(H) | |
Weight | Approx. 13kg ~ 15kg <29lb ~ 33lb> | |
Sample Gas Condition | Temperature: Less than 40°C <104°F> H2O Content: Standard or less at ambient temperature Dust: 0.1g/m3 or less Pressure: ±0.98 kPa |
・SD is a trade mark for SD-3C, LLC.
・TAKE GREAT CARE WHEN HANDLING SAMPLE GASES CONTAINING TOXIC OR FLAMMABLE GASES. TAKE MEASURES SUCH AS PROVIDING ADEQUATE VENTILATION, INSTALLING GAS DETECTORS, AND REMOVING IGNITION SOURCES IN THE WORKING AREA.
・THE PG-300 SERIES IS NOT EXPLOSION-PROOF. DO NOT USE THIS PRODUCT IN A HAZARDOUS LOCATION OR FOR MEASUREMENT OF SAMPLE GASES IN EXPLOSIVE ATMOSPHERES (MIXTURE OF A COMBUSTIBLE GAS AND AIR WITHIN THE FLAMMABILITY LIMITS). HORIBA, LTD. AND ITS AFFILIATES ARE NOT LIABLE FOR EMERGENCIES CAUSED BY LEAKAGE OR MISHANDLING OF SUCH GASES. Schematics