HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200 connects the DO (Dissolved Oxygen) sensor (DO-1100) and measures the DO in the sample water.The measurement method is membrane type polarography method. It is suitable for monitoring DO in wastewater treatment or aquarium for aquaculture.

Measurement range

Dissolved oxygen concentration: 0 - 20 mg/L
Saturation degree: 0 - 200 %
Temperature: 0 - 50 ℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Tough

  • Responds to harsh conditions at the site process
      Operating temperature range(Transmitter):-20 - 55℃
      Rated power supply voltage:AC 90 - 264 V ±10% 50/60 Hz
      Robust aluminum die cast (Protection code:IP65)
  • CE Marking and FCC Compliance suitable for use at overseas sites

 

Intelligence

  • Self-diagnosis of membrane damage and infiltration into the probe
  • Convenient function to display liquid temperature at the same time(Transmission output available)
  • Designed to be environmentally friendly (Pb-free) in response to WEEE and RoHS

 

Easy maintenance

  • Easy to view big display
  • Easy operation
  • Calibration log memory
  • Screw terminals that do not fall off are used in the terminal block for wiring
  • On-site membrane replacement as well as whole sensor replacement
  • Span calibration by air preceded by auto-zeroing (Electrical auto zeroing function)
Product nameDissolved oxygen converter
ModelHD-200
Combined sensor5505, 5510 (A bipolar diaphragm type polarography sensor)
Combined probeDO-1100
Measurement
range
Dissolved oxygen
concentration
0 mg/L to 20 mg/L (Display range: 0 mg/L to 22 mg/L)
Saturation degree0% to 200% (Display range: 0% to 200%)
Temperature0℃ to 50℃ (Display range: -10℃ to 110℃)
Display
resolution
Dissolved oxygen
concentration
0.01 mg/L
Saturation degree1%
Temperature0.1℃
PerformanceDissolved
oxygen
concentration
RepeatabilityWithin ±0.5% of the full scale (response for equivalent input)
LinearityWithin ±0.5% of the full scale (response for equivalent input)
TemperatureTemperature±0.5℃(response for equivalent input)
Linearity±0.5℃(response for equivalent input)
Transmission
output
Number of output2 (The negative terminals for transmission outputs are internally
connected at the same electric potential)
Output type4 mA to 20 mA DC: input/output isolated type
Load resistanceMaximum: 900Ω
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeOutput 1Dissolved oxygen concentration: Selection from preset ranges or free range input within measuring range.
Output 2Free setting within a range between -20℃ and 130℃
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact outputNumber of output3
Output typeNo-voltage contact output
Contact typeRelay contact; SPDT (1c)
Output capacity250 V AC 3 A, 30 V DC 3 A (resistance load)
Contact
function
R1 and R2Selectable from upper limit alarm, lower limit alarm, ON/OFF control, currently holding of transmission output, and cleaning output (The contact is closed during alarm operation, opened normally and while the power is down).
FAILError alarm (Closed in the normal state, opened in the failure state or while the power is down.)
Alarm setting rangeSelectable from dissolved oxygen concentration, and temperature
 
  • Setting range: Within the measurement range
  • Delay time: 0 to 600 seconds
 
Control setting range 
  • Setting range: 0 mg/L to 20 mg/L
  • Control width: 0.02 mg/L to 200 mg/L(±0.01 to ±0.50 mg/L)
 
Cleaning
output
Number of output points1
Output typeContact output with voltage (output of connected power supply voltage)
Contact typeRelay contact; SPST (1a)
Output contact capacity250 V AC 0.5 A
External instrumentSolenoid valve for cleaning control
SettingsCleaning period0.1 hours to 168.0 hours
Cleaning time2 seconds to 600 seconds
Hold time2 seconds to 600 seconds
Timer accuracyWithin 2 minutes per month
Description of cleaning
operation
One of the following operations.
  • Operation of internal timer only
  • Operation of internal timer and external input command
  • Enable the internal timer only when external input is active.
  • The cleaning trigger signal (The external trigger signal must be longer than 2 seconds)
 
Contact inputNumber of input1
Contact typeNo-voltage “a” contact of open collector
ConditionsON resistance: 100 Ω max.
Open voltage: 24 V DC
Short-circuit current: 12 mA DC max.
Contact functionExternal input for cleaning or transmission holding if cleaner is not attached.
Transmission
capability
Communication typeRS-485
Signal type2 wire system, isolated from the input circuit
Not isolated from transmission circuit
Temperature
compensation
Applicable temperature
element
Platinum resistor: 1 kΩ (0℃)
(The temperature sensor is built into the probe DO-1000.)
Temperature compensation
range
0℃ to 50℃
Temperature calibration1 point calibration comparing to reference thermometer
CalibrationCalibration methodSpan calibration in the air or DO saturated aquaous solution
Number of calibration pointsAtmospheric calibration: 1 point
(Zero electric calibration is carried out automatically)
Saturation liquid calibration : 2 points (zero calibration is omitted)
Additional capabilitiesSalinity compensation (0.0% to 5.0%)
Automatic detection of calibration failure (Zero error, Sensitivity error)
Calibration history (Elapsed days from the last calibration which ever zero or span, zero shift, span sensitivity)
Self-checkCalibration errorZero calibration error, sensitivity error, outside of temperature calibration range
Electrode diagnostic errorSensor error (damage to diaphragm), disconnection of sensor (or damage to sealing), temperature sensor short-circuit, and electric discontinuity of temperature sensor
meter errorCPU error, CPU error, ADC error, memory error
Operating temperature range-20℃ to 55℃ (without freeze)
Operating humidity rangeRelative humidity: 5% to 90% (without condensation)
Storage temperature-25℃ to 65℃
Power supplyRated power supply voltage100 V to 240 V AC ±10% 50/60 Hz
Power consumption15 VA (max)
OthersWith power switch for maintenance use
Compatible
standards
CE markingEMC  :EN61326-1
      Class A, Industrial electromagnetic environment
Safety  :EN61010-1
RoHS :EN50581
      9. Industrial monitoring and control instruments
FCC rulesPart15 Class A
StructureInstallationOutdoor installation type
Installation methodMounted on 50A pole or wall
Protection codeIP65IEC60529, JIS C0920
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of hoodSUS304 stainless steel (coated with epoxy-denatured melamine resin)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions 180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
Mass Main body: Approx. 3.5 kg; cover and mounting brackets: Approx. 1 kg

*1:   The standard for effect on the reading by the electromagnetic field of the radiated radio frequency and by the conducted interference is within the measured dissolved oxygen value ±0.4 mg/L.

*2:   When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

Aqualog
More Aqualog

Water Treatment Plant Analyzer

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

EMGA-920
More EMGA-920

Oxygen/Nitrogen Analyzer

EMGA-921
More EMGA-921

Hydrogen Analyzer

EMGA-930
More EMGA-930

Oxygen/Nitrogen/Hydrogen Analyzer

FES-310L
More FES-310L

Sanitary Conductivity Sensor (Flow Through type)

FS-01FC-SL Series
More FS-01FC-SL Series

Sanitary Conductivity Sensor (Flow Through type) for Low Concentrations

HC-200F (Four-Wire Analyzer)
More HC-200F (Four-Wire Analyzer)

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
More HC-200NH

Ammonia Nitrogen Meter

HC-300F
More HC-300F

Industrial simplified fluoride ion concentration meter

HD-200FL
More HD-200FL

Industrial dissolved oxygen analyzer (Four-Wire Analyzer)

HD-300
More HD-300

Industrial dissolved oxygen analyzer (Two-Wire Transmitter)

HD-480
More HD-480

Industrial dissolved oxygen analyzer (The Slim48 series)

HE-200C
More HE-200C

Industrial electric conductivity meter (Four-Wire Analyzer)

HE-200H (Four-Wire Analyzer)
More HE-200H (Four-Wire Analyzer)

Industrial electric conductivity meter

HE-200R
More HE-200R

Industrial electric resistivity meter (Four-Wire Analyzer)

HE-300C
More HE-300C

Industrial electric conductivity meter (Two-Wire Transmitter)

HE-300R
More HE-300R

Industrial electric resistivity meter (Two-Wire Transmitter)

HE-480C
More HE-480C

Industrial conductivity meter (low concentration type)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

ESH-01-C-SN
More ESH-01-C-SN

Sanitary Conductivity Sensor (Ferrule Clamp type) for Low Concentrations

FES-310L
More FES-310L

Sanitary Conductivity Sensor (Flow Through type)

FS-01FC-SL Series
More FS-01FC-SL Series

Sanitary Conductivity Sensor (Flow Through type) for Low Concentrations

HD-300
More HD-300

Industrial dissolved oxygen analyzer (Two-Wire Transmitter)

HD-480
More HD-480

Industrial dissolved oxygen analyzer (The Slim48 series)

HE-200C
More HE-200C

Industrial electric conductivity meter (Four-Wire Analyzer)

HE-200H (Four-Wire Analyzer)
More HE-200H (Four-Wire Analyzer)

Industrial electric conductivity meter

HE-200R
More HE-200R

Industrial electric resistivity meter (Four-Wire Analyzer)

HE-300C
More HE-300C

Industrial electric conductivity meter (Two-Wire Transmitter)

HE-300R
More HE-300R

Industrial electric resistivity meter (Two-Wire Transmitter)

HE-480C
More HE-480C

Industrial conductivity meter (low concentration type)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Industrial conductivity meter (high concentration type)

HE-480R
More HE-480R

Industrial resistivity meter

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960CW
More HE-960CW

2-channel Sanitary Conductivity Meter (Low Concentration type)

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
More HE-960HI

Sanitary Conductivity Meter (Wide-range type)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960R-GC(W)
More HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW
More HE-960RW

Industrial resistivity meter

HE-960RW-GC(W)
More HE-960RW-GC(W)

2-Channel Resistivity Meter

HE-960TM
More HE-960TM

TMAH Conductivity Meter. Perfect for Controlling TMAH Developer Concentrations

HF HD-960L
More HF HD-960L

Dissolved Oxygen Monitor in Low Concentration

HF-960H
More HF-960H

HF / HCl Concentration Monitor

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
More HF-SP-CU

2-channel High Precision HF Concentration Monitor

HO-200
More HO-200

Industrial ORP meter (Four-Wire Analyzer)