OBS-ONE PM unit

OBS-ONE PM - On-board Emissions Measurement

On-board Emissions Measurement System

On-board PM measurement for real-world results

OBS-ONE PM unit is the industry-leading on-board Particulate Matter (PM) measurement system. It collects PM on a filter paper, using a partial flow gravimetric sampling method, while simultaneously measuring real-time PM. A key feature of this design is the use of a venturi flow meter which enables reliable proportional sampling and accurate exhaust gas flow measurement under transient flow conditions. Combine the GAS unit and PM unit to perform certification tests on heavy duty and non-road vehicles.

Segment: Automotive
Manufacturing Company: HORIBA, Ltd.

 EPA CFR part 1065 Compliance

For Certification

  • US EPA CFR part 1065 subpart J
  • Simplify data collection and post-processing regulation requirements by using this measurement method

For R&D

  • Easily compare in-lab test results with real-road test results
  • Support R&D by simulating real-world driving events in the test cell with the Test Automation System STARS

 

◎ The world’s smallest PM measurement system in its class*

     *As of July 2015. Based on our company's research.

  • Easily mounted on any vehicle (modular and front access design)
  • One-touch fitting for module and cable connections

 

â—Ž The reliable test method for high speed flow rate control

  • PM transient measurement by proportional sampling

 

â—Ž User-friendly design mounts easily on any vehicle
   (modular and front-access design)

  • One-touch fitting for module and cable connections
  • Cartridge filters are easily changed 

Integrated Operation Software

OBS-ONE and other HORIBA ONE series measurement devices employ a common interface with future expandability. Control and management of each emission measurement device can be integrated into a single controller, as well as provide notifications of system health.

Measuring PrinciplesBatch sampling: Filter gravimetric method
Real-time PM measurement : Diffusion charging method
Measuring Ranges (Real-time PM sensor)0 to 2500 mm/cm3 (Concentration after dilution)
Dilution MethodPartial flow dilution method (Proportional sampling mode/Fixed dilution ratio mode)
Signal for Gas SamplingExhaust gas flow rate: Isolated analog signal (0-10 V)
Flow Rate of Diluted Gas10 to 15 L/min (Under the conditions of 20 deg.C and 101.3 kPa)
Filter HolderDiameter 47 mm, Effective diameter 26.2 mm (Without backup filter)
Particle Pre-classifier (Cyclone)99% penetration of particle size of less than 1 μm
50% cut off point: particle size between 2.5 and 10 μm
Power RequirementsDC 24 V
Power ConsumptionMax. 0.6 kVA
Dimensions350(W) x 470(D) x 460(H) mm (Excluding controller and protruding objects)
MassApprox. 45 kg (Excluding controller)
Operating ConditionsTemperature: 0 to 40 deg.C (During operation)
Relative humidity: less than 80%  Altitude: 0 to 2000 m above sea level

System Configuration

Combination of PM measurement unit and GAS measurement unit

RDE Test with Portable Emission Measurement System (PEMS)
RDE Test with Portable Emission Measurement System (PEMS)
In 2016 the European Commission´s (EC) Member States agreed on new procedures and requirements for light-duty vehicle type approval certification introducing Portable Emission Measurement System (PEMS) for vehicle testing on the road.
RDE tests on the chassis dynamometer
RDE tests on the chassis dynamometer
Real driving emissions with RDE CoDriver
Real driving emissions with RDE CoDriver
Real Driving Emission (RDE) tests confirm the results produced during an emissions test on a chassis dynamometer to ensure that vehicles meet the set limits in the real world.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CVS-ONE
CVS-ONE

Constant Volume Sampler

FTX-ONE-CL
FTX-ONE-CL

FTIR Exhaust Gas Analyzer Dilute Measurement Type

FTX-ONE-CS/RS
FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

MDLT-ONE
MDLT-ONE

Micro Dilution Tunnel

MEDAS
MEDAS

Dynamic Altitude Simulation

MEDAS Humidity Module
MEDAS Humidity Module

Altitude Simulator

MEDAS Temperature Module
MEDAS Temperature Module

Altitude Simulation

MEXA-1300R
MEXA-1300R

Motor Exhaust Gas Analyzer

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

MEXA-ONE
MEXA-ONE

Motor Exhaust Gas Analyzer

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

Laser Spectroscopic Motor Exhaust Gas Analyzer

OBS-ONE GS Unit
OBS-ONE GS Unit

On-board Emissions Measurement System

OBS-ONE PN Unit
OBS-ONE PN Unit

On-board Emissions Measurement System

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

On-board SPN10 measurement for real-world

OBS-ONE-XL (IRLAM)
OBS-ONE-XL (IRLAM)

On-board NH3/N2O Measurement System for real-world driving

PTFM-1000V2
PTFM-1000V2

Pitot Tube Exhaust Flow Meter

PTFM-ONE-DT
PTFM-ONE-DT

Dual Pitot Tube Exhaust Flow Meter

Torque Matching
Torque Matching

Road-to-Rig Chassis Dyno Replication

AP-370 Series
AP-370 Series

Air Pollution Monitor

APDA-371
APDA-371

Ambient Dust Monitor

APDA-372
APDA-372

Ambient Dust Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

MESA-50
MESA-50

X-Ray Fluorescence Analyzer

MESA-50K
MESA-50K

X-Ray Fluorescence Analyzer

MEXA-2000SPCS series
MEXA-2000SPCS series

Solid Particle Counting System

TFH-01/47
TFH-01/47

PTFE Filter/TFH membrane

XGT-9000
XGT-9000

X-ray Analytical Microscope (Micro-XRF)

XGT-9000SL
XGT-9000SL

X-ray Analytical Microscope
with a Super Large Chamber