Pitot Tube Flow Meter
The Pitot Tube Flow Meter, PTFM-1000V2 is a standalone interface for measuring exhaust gas flow rate of combustion engines. The system uses the tried-and-tested pitot tube principle with high-frequency transducers to accurately measure highly pulsating exhaust flows with a sampling rate of 1kHz. This rapid capture rate ensures that any pulsations or exotic behaviour in an engine is measured, and the unique design of the PTFM pitot tube means reverse flows can be measured with the same guarantee of sensitivity. The interface can be run standalone with a laptop, or seamlessly integrated to run alongside an analyser system without adding any more steps to the test cycle process.
Key Features:
Optional Features:
Test vehicle/engine | Diesel (HDD, LDD), Gasoline, LPG and CNG vehicles, Ethanol, Propane, Butane | ||
---|---|---|---|
Configuration | Interface unit connected to pitot tube via umbilical cable. Pitot tube can be standard (0 - 230ºC) or high temperature (0 - 900ºC) | ||
Flow Rate Accuracy | Within ±1 % of full scale or ±1.5 % of readings (at flow rate of 20 % of full scale) | ||
Linearity | Either of the following: (a) Within ±2.0% of full scale (b) Intercept: |a0| ≤ 1.0% of full scale Slope: 0.98 ≤ a1 ≤ 1.02 Standard estimated error: SEE ≤ 2.0% of full scale Coefficient of determination: R2 ≥ 0.990 | ||
Response Time | <1ms | ||
Tube Attachments | Pitot tube size should be selected from the following list, according to tailpipe diameter and exhaust flow rate: | ||
Pilot Tube | Tube Diameter | Max Flow | |
A-type | 32.0 mm | 2.0 m3/min | |
B-type | 42.7 mm | 4.5 m3/min | |
C-type | 60.5 mm | 10 m3/min | |
D-type | 76.3 mm | 15 m3/min | |
E-type | 89.1 mm | 20 m3/min | |
F-type | 101.6 mm | 30 m3/min | |
G-type | 127.0 mm | 45 m3/min | |
H-type | 152.4 mm | 65 m3/min | |
Noise | Within 2.0% of full scale (at flow rate of 20% of full scale) | ||
Repeatability | Within ±2.0% of readings (at flow rate of 20% of full scale) | ||
Calibration | Interface calibrated every 12 months. Recommended pitot tube calibration every 12 months |
Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.
FTIR Exhaust Gas Analyzer Dilute Measurement Type
FTIR Exhaust Gas Analyzer Direct Measurement Type
Heated Type NOx Analyzer
Heated Type THC Analyzer
Motor Exhaust Gas Sulfur Analyzer
Motor Exhaust Gas Analyzer
Solid Particle Counting System
FTIR Motor Exhaust Gas Analyzer
Laser Spectroscopic Motor Exhaust Gas Analyzer
On-board Emissions Measurement System
On-board Emissions Measurement System for NH3/N2O
On-board Emissions Measurement System
On-board Emissions Measurement System
On-board Emissions Measurement System for SPN10
Dual Pitot Tube Flow Meter
Pressure Insensitive Mass Flow Module
Exhaust Pressure Controller
Wafer Back Side Cooling System
Digital Liquid Mass Flow Meters / Controllers
Compact Baking System
POCl3 Auto Refill System
Mixed Injection System Liquid Vaporizers
Dual Pitot Tube Flow Meter
Mass Flow Controller
High Temperature Digital Mass Flow Controller
Mass Flow Controller
Digital Mass Flow Controller
Multi Range/Multi Gas Digital Mass Flow Controller
New concept Pressure Insensitive Mass Flow Controller
Pressure Insensitive Mass Flow Controller
Digital Automatic Pressure Regulator