Dual Pitot Tube Flow Meter
The Dual Pitot Tube Flow Meter, PTFM-ONE DT is a standalone interface for measuring exhaust gas flow rate of combustion engines. The system uses the tried-and-tested pitot tube principle with high-frequency transducers, with a sampling rate of 1kHz to accurately measure highly pulsating exhaust flows. This rapid capture rate ensures that any pulsations or exotic behaviour caused by the engine is measured, and the unique design of the PTFM-ONE DT means reverse flows can be calculated, with the same guarantee of sensitivity.
The interface can run standalone with a laptop, or seamlessly integrated to run alongside a Test Automation System.
900°C Exhaust Gas Limit | Allows the freedom to test engines under extreme conditions without worrying if the flow meter can handle those temperatures |
-1.25kPa to +7.5kPa Sensor Range | Shows both positive flow & negative flow in the tailpipe. Also, HORIBA capped the positive pressure at +7.5kPa to ensure we cause as little backpressure on your engine as possible |
Dual Tube System | This is the patented setup of 2 pitot tubes and a valve to switch automatically to keep the system measuring with it best possible accuracy range. It uses the smaller tube for flows below 4.5 m3/min and both tubes if flows peak above the smaller tubes flow limit up to 14.5m3/min. |
1Khz High Speed Transducers | Having fast sampling of the pressure changes in the tailpipe allow for a rapid visual representation of the spikes and negative pulses that happen with a combustion engine. Lower speed sampling would miss these spikes and negatives giving you an inaccurate representation of what is happening inside the tailpipe. |
Temperature Compensation | The PTFM-ONE automatically compensates to 20°C when testing so there is no need to warm up. |
Multiple Communication Options | The PTFM-ONE has 2 connection options. LAN for AK connections to Automation systems or the PTFM Host programme & Analogue out (0-10V with 4 configurable channels available) |
2 Options of Absolute Pressure Sensors | The PTFM-ONE can be purchased in 2 absolute pressure ranges supporting testing from sea level to a) 2100m or b) 4500m. |
System Configuration (Standard unit) |
|
---|---|
Tube Diameter & Measuring Range | The System comes with a B & C Tube in parallel with each other and a valve in between.
Both B and C Tubes work in parallel with each other, providing a Max Flow of 14.5 m3/min. |
Linearity | Either of the following:
|
Flow Rate Accuracy | Within ±1 % of full scale or within ±1.5 % of readings (whichever larger) (at flow rate of 20 % of full scale) |
Exhaust Pressure Sensor Range | -1.25 – 7.5 kPa |
Atmospheric Pressure Sensor Range |
|
Environment for use |
|
Approved Standards | CE, FCC, RoHS compliant |
Dimensions | 923 x 480 x 1204 H x W x D (mm) |
Mass | 115KG Approx. |
Sie haben Fragen oder Wünsche? Nutzen Sie dieses Formular, um mit unseren Spezialisten in Kontakt zu treten. * Diese Felder sind Pflichtfelder.
FTIR Exhaust Gas Analyzer Dilute Measurement Type
FTIR Exhaust Gas Analyzer Direct Measurement Type
Heated Type NOx Analyzer
Heated Type THC Analyzer
Motor Exhaust Gas Sulfur Analyzer
Motor Exhaust Gas Analyzer
Solid Particle Counting System
FTIR Motor Exhaust Gas Analyzer
Laser Spectroscopic Motor Exhaust Gas Analyzer
On-board Emissions Measurement System
On-board Emissions Measurement System for NH3/N2O
On-board Emissions Measurement System
On-board Emissions Measurement System
On-board Emissions Measurement System for SPN10
Pitot Tube Flow Meter
Pressure Insensitive Mass Flow Module
Carbon Sensor Conductivity Meter (Low concentration type)
Industrial resistivity meter
KOH Monitor
Wide range TMAH Concentration Monitor
High Precision TMAH Concentration Monitor