HR-200RT

Field-installation type residual chlorine meter

HORIBA's long-selling water quality meter that excels in indoor applications.

Ideal for measuring the concentration of free residual chlorine in tap water, swimming pools, spas and similar environments. By adopting physical polishing cleaning with rotating electrodes, long-term stable measurements can be achieved.

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Parts can be replaced without the use of tools

Consumables (cathode electrode, filter, beads) can be replaced without the use of tools.

Equipped with rotation stop detection function and re-rotation function

If the rotating sensor stops, an error message will be displayed. Additionally, it will automatically initiate re-rotation.

Equipped with pH correction function

The HORIBA pH meter (HP-200) can be connected, applying pH correction to the residual chlorine measurement values.

Converter

Product name Residual Chlorine Monitor
Model HR-200RT
Sensor type RA-30
Measurement
range
Concentration 0 mg/L to 3 mg/L (Display range: 0 mg/L to 5 mg/L)
Temperature 0℃ to 50℃ (Display range: -10℃ to 110℃)
Display
resolution
Concentration 0.01 mg/L
Temperature 0.1℃
Performance Concentration Repeatability Within ±0.05 mg/L (Equivalent input)
Linearity Within ±0.05 mg/L (Equivalent input)
Temperature Repeatability ±0.5℃ (Equivalent input)
Linearity ±0.5℃ (Equivalent input)
Transmission
output
Number of current outputs 2 (Negative terminals of each transmission output channel are connected inside and thus have the same electrical potential)
Output type 4 mA to 20 mA DC, input/output isolated type
Load resistance 900 Ω (Max.)
Linearity Within ±0.08 mA (limited to the current linearity)
Repeatability Within ±0.02 mA (limited to the current repeatability)
Output range Output 1 Residual chlorine concentration: An arbitrary value can be set within the range from 0 mg/L to 5 mg/L
Output 2 Temperature: An arbitrary temperature can be set within the range from -10℃ and 110℃
Error output Provided with burnout function (3.8 mA or 21 mA)
Hold function Selectable from between the latest value hold and the preset value hold
Contact output Number of current outputs 4
Output type No-voltage output contact
Contact type Relay contact, R1 to R3: SPST (1a), FAIL: SPDT (1c)
Output capacity R1, R2, FAIL: 250 V AC 3 A/30 V DC 3 A (resistance load)
R3: 30 V DC 1 A (resistance load)
Contact
function
R1, R2, R3 Selectable from among the upper limit alarm, lower limit alarm, ON/ OFF control, during transmission output hold, and during calibration
(closed at alarm operation, open under normal conditions and in a power-OFF state)
FAIL Error alarm (closed under normal conditions, open in an error or power-OFF state)
Description of alarm operation
  • Setting range: 0.00 mg/L to 3.00 mg/L
  • Delay time: 0 s to 600 s
Description of control operation
  • Setting range: 0.00 mg/L to 3.00 mg/L
  • Control width: 0.02 mg/L to 1.00 mg/L (±0.01 mg/L to 0.50 mg/L)
Contact input Number of input points 2
Contact type Open collector no-voltage “a” contact
Condition ON resistance: 100Ω (max.)
Open-circuit voltage: 24 V DC
Short-circuit current: 12 mA DC (max.)
Contact function Selectable from among the external input for transmission output hold, flow switch input for interlock (open when the flow rate drops), and calibration command
Communicati
on function
type RS-485
Number of circuits 1
Signal form Two wire type, the power source of the communication is isolated from the power of measurement circuit (the power source of transmission and communication are not isolated).
pH correction Type Connected with expansion connector
pH correction range 5.8 pH to 8.6 pH
Temperature
compensation
Applicable temperature element Pt1000: 1 kΩ (0℃) (embedded in the detector unit)
Compensation range 0℃ to 50℃
Calibration function One point calibration compared with reference temperature range
Calibration Calibration method Zero calibration (with zero water)
Span calibration (comparative calibration with the value measured with the DPD method including electrical zero calibration)
Additional function Calibration log (number of days elapsed since the zero or last calibration), calibration error automatic judgment (zero)
Calibration
control output
(ZERO CAL)
Number of contact output 1
Output type Voltage contact output (connected power source voltage output)
Contact capacity 250 V AC 0.5 A
Calibration cycle setting 1 hour to 999 hour
CALR1 Contact type Relay contact, SPST (1a)
Contact function Zero water switching driven by solenoid valve
Self-check Calibration error Zero calibration error, outside the temperature calibration range
Temperature sensor diagnosis Temperature sensor short-circuit, temperature sensor disconnection
Converter error CPU abnormality, ADC abnormality, memory abnormality
Operating temperature range -20℃ to 55℃ (without freezing)
Operating humidity range Relative humidity: 5% to 90% (no condensation)
Storage temperature -25℃ to 65℃
Power supply Rated power supply voltage 100 V to 240 V AC ±10% 50/60 Hz
Power consumption 35 VA (max.)
Others With built-in power switch for maintenance
Structure Installation Outdoor installation type
Installation method Pole-mounted or wall-mounted
Protection class IP65
Material of case Aluminum alloy (coated with epoxy-modified melamine resin)
Material of mounting brackets SUS304
Material of sun shade hood SUS304 (coated with epoxy-modified melamine resin)
Material of display window Polycarbonate
Display element Reflective monochrome LCD
External dimensions 180 (W) mm × 155 (H) mm × 115 (D) mm (excluding brackets)
Mass Main frame: approx. 3.5 kg, Hood, bracket: approx. 1 kg

Note

Although an arrestor (400 V discharge starting voltage) is mounted for the transmission output, contact input, and communication, install an optimum surge absorber element on the connection line, depending on the surrounding environment, device installation conditions, and externally connected devices.

Detector and measuring cell

Product name Rotating electrode polarographic residual chlorine sensor
Model RA-30
Measurement method Rotating electrode polarographic method
Measurement target Free residual chlorine in sample water
Measurement range 0 mg/L to 3.00 mg/L
Temperature compensation Automatic temperature compensation using Pt1000
Performance Linearity Within ±5% full-scale range
Repeatability Within ±2% full-scale range or ±0.05 mg/L, whichever is larger
Response time Within 120 s from the inlet of the measuring cell (90% response)
Zero drift Within ±1% full-scale range/month
Span drift Within ±10% full-scale range/month
Sample
condition*6
Temperature 0℃ to 45℃
Flow rate Measuring cell flow rate: 0.1 L/min to 0.5 L/min*1
Primary pressure 0.01 MPa to 0.15 MPa*2
pH value 5.8 pH to 8.6 pH (with no fluctuation over 1.0 pH)*3
Electrical conductivity 8 mS/m or more*4
Calibration Zero calibration Zero water calibration, electrical zero calibration
Span calibration Comparative calibration with the value measured with the DPD method
(including electrical zero calibration)
Material of
liquid contact
section
Electrode Au, AgCI
Beads Ceramic beads
Filter Nylon
Other PVC, PPO, PTFE, EPDM, Q
Piping
connection
sample inlet φ6 mm × φ8 mm tube or Rc1/8
sample outlet VP16
Cleaning method Physical cleaning with beads
Cable length Provided standard cable: 1.5 m, max. extension distance: 10 m
Operating temperature range 0℃ to 45℃*5
Operating humidity range Relative humidity: 5% to 90% (no condensation)
Storage temperature 0℃ to 45℃
Structure Installation method 50 A pole-mounted or wall-mounted
Protection class IP53
External dimensions 110 (W) mm × 340 (H) mm × 110 (D) mm (excluding brackets)
Mass Approx. 1.5 kg
Standard accessories Beads, abrasive paper, mesh filter (2 types), O-ring

1: If use our designated flow switch (RA-FS30), regulate flow rate in 0.3 L/min to 0.5 L/min.
2: The measurement section is under an open air environment.
3: If pH of the measured sample varies, the value of residual chlorine also varies. Perform measurement in an environment in which pH variations are less likely to occur.
4: Measurement cannot be performed correctly when the electrical conductivity falls below 8 mS/m (80 μS/cm). Be sure to perform measurement in this conditions.
5: If the electrode is exposed to the direct sunlight, the anode and cathode electrode could deteriorate. Install the instrument where it is not exposed to direct sunlight (indoors).
6: If a reducing agent or oxidizer exists in a sample, it affects the reading. Do not use a sample containing a reducing agent such as thiosulfate or sulfite, or oxidizer such as O3, hydrogen sulfide or chlorine dioxide, as measurement cannot be performed correctly.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount type conductivity meter

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HF-700A
HF-700A

Low Concentration Monitor- Sulfuric Acid/Hydrogen Peroxide

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HO-480
HO-480

Panel-mount type ORP meter

HR-200
HR-200

Field-installation type polarographic residual chlorine meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

HT-110
HT-110

On-line TOC analyzer

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor