HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200H connects conductivity sensor (FES-12X/2XX/310 Series) and measures conductivity and temperature in the sample water. It can be used not only for measurement of electrical conductivity in aqueous solution, but also for concentration adjustment and rinse monitoring of CIP, etc., as well as for concentration monitor of process.

Measurement range

Conductivity: 0 - 2000 mS/cm, 0.0 - 200.0 S/m
Temperature: 0.00 - 100.00 ℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Tough

  • Responds to harsh conditions at the site process   
    Operating temperature range(Transmitter):-20 - 55℃   
    Rated power supply voltage: AC 90 - 264 V 50/60 Hz   
    Robust aluminum die cast (Protection code:IP65)
  • CE Marking and FCC Compliance suitable for use at overseas sites

 

Intelligence

  • Convenient function to display liquid temperature at the same time(Transmission output available)
  • Sensor error can be detected immediately by self-diagnosis function
  • Designed to be environmentally friendly (Pb-free) in response to WEEE and RoHS
  • Sea water salinity and NaCl concentration conversion function
  • Automatic HNO3/H3PO4/NaOH concentration conversion function

 

Easy maintenance

  • Easy to view big display
  • Easy operation
  • Calibration log memory
  • Screw terminals that do not fall off are used in the terminal block for wiring
Product nameConductivity meter
ModelHE-200H
Sensors in combination4-electrode method conductivity sensor (FES Series) of cell constant 0.1/cm, or 1.0/cm
Measuring
range
Measurement
type
UnitCell constant
(/cm)
0.1
(FES-2XX, 310 series)
1.0
(FES-125, 126)
ConductivitymS/cm0.000 to 2.000
0.00 to 20.00
0.0 to 200.0
0 to 2000△(*Note2)△(*Note2)
Auto (*Note1)
Practical region
(*Note2)
0 to 5000 to 1000
Display range0 to 2200
S/m0.000 to 0.2000
0.00 to 2.000
0.00 to 20.00
0.0 to 200.0△(*Note2)△(*Note2)
Auto (*Note1)
Practical region
(*Note2)
0.0 to 50.00.0 to 100.0
Display range0.0 to 220.0
Temperature0℃ to 100℃ (display range: −30℃ to 160℃)
Salinity
conversion
capability
Seawater0.00% to 4.00%
NaCl0.0% to 20.0%
Concentration
conversion
capability
NaOH0.00% to 5.00%
HNO30.00% to 5.00%
H3PO40.00% to 5.00%
Option 1 to 40.00% to 100.00%
Display
resolution
Conductivity
Conversion density
As shown in the measuring and conversion table.
Temperature0.01℃
PerformanceConductivityRepeatability
(mS/cm)
Cell constant0.1 (/cm)1.0 (/cm)
0.00 to 20.00Within ±0.5% of the full scaleWithin ±0.5% of the full scale
20.0 to 200.0Within ±1.0% of the full scaleWithin ±0.5% of the full scale
200 to 1000Within ±1.0% of the full scale
Conditionresponse for equivalent input
Linearity
(mS/cm)
Cell constant0.1 (/cm)1.0 (/cm)
0.00 to 20.00Within ±0.5% of the full scaleWithin ±0.5% of the full scale
20.0 to 200.0Within ±1.0% of the full scaleWithin ±0.5% of the full scale
200 to 1000Within ±1.0% of the full scale
Conditionresponse for equivalent input
PerformanceTemperatureRepeatability±0.1℃ (response for equivalent input)
Linearity±0.5℃ (response for equivalent input)
Transmission
output
Number of output2 (The negative terminals for transmission outputs are internally connected at the same electric potential)
Output type4 mA to 20 mA DC: input/output isolated type
Load resistanceMaximum: 900Ω
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeOutput 1Conductivity or density converted: Free setting within a measuring range.
Output 2Temperature: Free setting within a range between −30℃ and 160℃
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact
output
Number of output3
Output typeNo-voltage contact output
Contact typeRelay contact; SPDT (1c)
Contact capacityAC 250 V 3 A, DC 30 V 3 A
Contact
function
R1 and R2Selectable from upper limit alarm, lower limit alarm, and currently holding of transmission output.
(The contact is closed during alarm operation, opened normally and while the power is down.)
FAILError alarm
(Closed in the normal state, opened in the failure state or while the power is down.)
Alarm setting rangeSelectable from conductivity and density
 
  • Setting range: Within a measuring range
  • Delay time: 0 to 600 seconds
 
Contact inputNumber of input2
Contact typeNo-voltage "a" contact for open collector
ConditionsON resistance: 100Ω max.
Open voltage: 24 V DC
Short-circuit current: 12 mA DC max.
Function of inputThe input signal use can be changed.
Two inputs for four output current range selection, or, one input for two current range selection and one input for holding.
The display also responds for the range selection by input.
Communication functionCommunication typeRS-485
Signal type2 wire system, isolated from the input circuit
Not isolated from transmission circuit
Temperature
compensation
Temperature elementPlatinum resistor: 1 kΩ (0℃)
Compensation method 
  • Temperature characteristics of NaCl (reference temperature: 5℃ to 95℃)
  • Arbitrary temperature coefficient input (reference temperature: 5℃ to 95℃; temperature coefficient: ±3%/℃)
  • No temperature compensation
    One of the three ways of compensation is selectable.
 
Temperature compensation
range
0℃ to 100℃ (However, the compensation calculation is extended lower than 0℃ or higher than 100℃.)
CalibrationConductivityBased on parameter input of coefficient for the sensor cell constant.
Self-checkSensor diagnosis errorTemperature sensor short-circuit, temperature sensor disconnection, and out of the temperature measurement range
ConverterCPU error, ADC error, and memory error
Operating temperature range−20℃ to 55℃ (without freeze)
Operating humidity rangeRelative humidity: 5℃ to 90℃ (without condensation)
Storage temperature−25℃ to 65℃
Power supplyRated power supply voltage100 V to 240 V AC ±10% 50/60 Hz
Power consumption15 VA (max)
OthersWith power switch for maintenance use
Compatible
standards
CE markingEMC    :EN61326-1
     Class A, Industrial electromagnetic environment
Safety   :EN61010-1
RoHS   :EN50581
     9. Industrial monitoring and control instruments
FCC rulesPart15 Class A
StructureInstallationOutdoor installation type
Installation methodMount on 50 A pole or wall
Protection codeIP65
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of foodSUS304 stainless steel (coated with epoxy-denatured melamine resin)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions180 (W) mm x 155 (H) mm x 115 (D) mm (excluding mounting brackets)
MassMain body: Approx. 3.5 kg; cover and mounting brackets: Approx. 1 kg

Note

  • Note 1  : The decimal point position changes automatically
  • Note 2  : The actual limit of measuring range of raw conductivity is 500 mS/cm for 0.1/cm and 2000 mS/cm for 1/cm sensor. (The sensor durability for chemicals is not assumed.)
  • Note 3  : When the sensor cable, the transmission cable, or the contact input cable is extended by 30 m or more, the surge test under the EMC Directive for CE marking is not applied.
  • Note 4  : An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

Aqualog
More Aqualog

Water Treatment Plant Analyzer

Aqualog Datastream
More Aqualog Datastream

For Instant Water Quality Reports

514-22
More 514-22

1.41 mS/cm Conductivity Standard Solution

514-23
More 514-23

12.9 mS/cm Conductivity Standard Solution

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
More CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
More CS-900

Non-Contact Chemical Concentration Monitor

HC-200F
More HC-200F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
More HC-200NH

Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)

HC-300F
More HC-300F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200FL
More HD-200FL

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
More HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HD-200
More HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-300
More HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
More HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
More HD-960L

Dissolved Oxygen Monitor in Low Concentration

HE-200C
More HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200R
More HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
More HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
More HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
More HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
More HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960CW
More HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
More HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
More HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
More HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW
More HE-960RW

Panel-mount Type Resistivity Meter(Four-Wire Transmission, 2-channel)

HE-960RW-GC(W)
More HE-960RW-GC(W)

2-Channel Resistivity Meter

HE-960TM
More HE-960TM

TMAH Conductivity Meter. Perfect for Controlling TMAH Developer Concentrations

HF-960H
More HF-960H

HF / HCl Concentration Monitor

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
More HF-SP-CU

2-channel High Precision HF Concentration Monitor

HO-200
More HO-200

Field-installation Type ORP Meter (Four-Wire Transmission)

HO-300
More HO-300

Field-installation Type ORP Meter (Two-Wire Transmission)

HO-480
More HO-480

Panel-mount Type ORP Meter (Four-Wire Transmission)

HR-200
More HR-200

Feild-installation Type Residual Chlorine Meter (Four-Wire Transmission, Water flow beads)

HR-200RT
More HR-200RT

Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)

HR-480
More HR-480

Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission)

HT-110
More HT-110

Total Organic Carbon Monitor