PoliSpectra® Quad

PoliSpectra® Quad Spectrometer
PoliSpectra Quad Optical Layout
PoliSpectra Quad Spectral Coverage
PoliSpectra Quad Quantum Efficiency

Multichannel Grating Spectrometer

Horiba’s OEM Polispectra Quad spectrometer is an integration of four VS70 spectrometers built around Horiba JY Type-IV flat-field aberration-corrected holographic concave gratings. This high throughput VIS spectrometer with 4 fiber inputs provides simultaneous acquisition of 4 channels at high speed with minimal crosstalk. The main electronics board is designed to read the two CCDs on the system simultaneously and provides 1-8X binning capability. This OEM system is a unique and innovative approach to drastically reduce the cost per channel. 

For OEM Industrial Low-light Applications

  • Fluorescence 
  • Emission (OES)
  • Absorbance
  • Reflectance
  • Examples:
    • Body Fluids Analysis 
    • Flow Cytometry
    • LED Testing, Colorimetry
    • Food Analysis Moisture Content

 

Spectroscopy in 60 Seconds - PoliSpectra Quad Video (1:09)

*Available in select countries.

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

Segment: Scientific
Manufacturing Company: HORIBA Scientific

Spectroscopy in 60 Seconds - PoliSpectra Quad Video (1:09)

 

  • Simultaneous acquisition of 4 channels
  • Excellent light purity with a typical 0.05% channel to channel crosstalk
  • Spectral acquisition time as low as 1.3 ms for all 4 channels 
  • High throughput (f/2.3)
  • Ultra-low stray light with aberration correction holographic grating
  • High SNR and dynamic range
  • TTL in/out to trigger each and all channels
  • Compact size, robustness, stability and affordability 

 

CCD Quantum Efficiency

 

Simultaneous measurement of 4 colors LED array spectra with Polispectra Quad spectrometer

Polispectra Quad Spectrometer is capable of simultaneously measuring 4 channels, the picture above shows the emission spectra of 4 different color LEDs measured using Ø 200 µm core fibers
 

Raw Throughput Uniformity

Raw throughput uniformity of better than 75% for 1000 production units measured channel to channel

 

OEM Spectrometer Selection Guide

View and Download our OEM Spectrometer Selection Guide

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

 

General Spectrometer Specifications*

Spectral Coverage

Tunable from 470 to 730 nm

Spectrometer Input

FC (standard), other input types available upon request

Spectral Resolution

2.7 nm with 75 µm slit; 5 nm for  Ø 200 µm fiber (no slit)

Average Spectral Dispersion

23.56 nm/mm; 0.33 nm/pixel (14 µm pixel CCD detector)

Crosstalk (channel to channel)

< 0.05% (typical)+
< 0.1% (maximum)

Focal Length

70 mm

F/#

~ F/2.3

Stray Light Rejection (< 590 nm or > 680 nm)

< 0.05 % (typical) 

Wavelength Accuracy

< 0.25 nm (average between 500 nm and 710 nm)

Software

LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)

Back-illuminated linear CCD Detector
CCD Detector ModelHamamatsu S11071-1104N 
CCD Sensor Format2048 x 22  (2 spectra per CCD of about 1000 pixels each)
CCD Pixel Size 14 x 14 µm
CCD Height 0.3 mm
CCD QE at 20° CQE = 63% at 250 nm; 76% at 650 nm; 55% at 850 nm
Scan Rates2 MHz
Full Well Capacity> 225,000 e¯/pixel (minimum); 250,000 e¯/pixel (typical)
CommunicationUSB 2
Scan Rates45 kHz and 500 kHz
Readout Noise23 e¯ (typical) to 35 e¯ (maximum)
Maximum Spectral Rate720 spectra/s with 0 ms exposure time 
Digitization16-bit ADC
Dynamic Range
(typical for single pixel)
11,000:1 (typical)
7,300:1 (minimum)
Non-linearity
(measured on each system)
<0.8% (typical)
1.5% (maximum)
Dark Current at –45° C                                 
Note: Pixel Size = 14 μm
50 e¯/pixel/s (typical)
Environmental ConditionsOperating temperature 15° C to 35° C ambient
Relative humidity <70% (non-condensing)
Storage temperature -25° C to 45° C
Power requirements
AC/DC power supply (provided)
90-264 VAC, 47–63 Hz

*Specifications, form factor, and spectrometer cover subject to change without notice. 
No LabVIEW™ license is needed to run our acquisition software.

+ This value includes optical and electronic crosstalk

 

Mechanical Drawings

Download Mechanical Drawings

 

You can email OEM Technical Sales at: OEM.US(at)horiba.com or contact OEM at: +1.732.494.8660 Ext. 7733

Request for Information