X-ray Fluorescence Sulfur-in-Oil Analyzer
HORIBA Scientific, a market leader in sulfur-in-oil analysis, announces the launch of the new SLFA-6100/6800 Energy Dispersive X-ray Fluorescence Analyzer, which measures sulfur in oil ranging from 5 ppm to 9.9999%. This new, compact, and accurate analyzer meets the needs of anyone wishing to conform to ASTM D4294, ISO 8754 or JIS K2541/B7995.
The SLFA-6000 series has an optimized user interface, which includes full-color monitor, USB output, data printout mode option and smaller footprint with a sophisticated look. A shutter shield has once again been adopted to prevent X-ray leakage, along with a new key switch function and a newly designed turntable.
The measurement is set between 10 to 600 seconds.
Up to 8 samples on SLFA-6800 turntable are analyzed with the pre-set condition.
After selecting the calibration curves and measurement conditions (or select the correct calibration curve using the “A” mode), simply press the “MEAS” button to start the measurement.
The software allows up to 5 sets of 3 calibration curves, to increase the accuracy and usability.
Click here to watch a video on the SLFA-60/6800.
Measurement principle | X-ray Fluorescence Analysis Method |
---|---|
Measurement sample | Sulfur in petroleum products such as heavy oil, naphtha, crude oil and light oil |
Measurement range | 5 ppm - 9.9999 % |
Repeatability | 5 ppm or less with a 1% sulfur sample, 1.6 ppm or less with a 0% sulfur sample |
C/H error correction | ± 50 ppm or less per C/H (with a 1 % sulfur sample) |
Lower detection limit | 5 ppm or less * * 3 times the standard deviation with a 0% sample |
Number of calibration curves | Up to 15 calibration curves |
Calibration curve order | Linear or Quadratic (both automatic selection and manual settings are available) |
Amount and number of samples | 4 - 10 mL, 1 sample(SLFA-6100) 4 - 10 mL, 8 samples(SLFA-6800) |
Measurement time | 10 - 600 sec |
Data output | Printout, USB memory stick, USB cable connected to PC |
Spectrum measurement | Energy Range: 0 - 10 keV, spectrum analysis to verify instrument performances |
Operating temperature | + 5 ˚C to + 40 ˚C (+ 41 ˚F to 104 ˚F) |
Operating humidity | 80% max relative humidity in temperature range + 5 ˚C to + 30 ˚C (+ 41 ˚F to 86 ˚F) Linear decrease to 50% relative humidity in temperature range + 31 ˚C to + 40 ˚C (+ 88 ˚F to 104 ˚F) |
Power supply | AC 100 - 240 V +/- 10%, 50/60 Hz |
Power consumption | 150 VA |
Dimentions [W x D x H] | 403 x 468 x 210 mm |
Weight | Approx. 21 kg (SLFA-6100) |
ASTM D4294 (USA), ISO 8754, JIS K2541/B7995 |
Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.
Carbon/Sulfur Analyzer
Total Nitrogen and Sulfur Analyzer
Total Halogen and Sulfur Analyzer
Measurement of Sulfur and Chlorine in Petroleum Products
X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer
X-ray Fluorescence Sulfur-in-Oil Analyzers
Total Nitrogen and Sulfur Analyzer
Total Halogen and Sulfur Analyzer
Measurement of Sulfur and Chlorine in Petroleum Products
X-ray Fluorescence Sulfur/Chlorine-in-oil Analyzer
X-ray Fluorescence Sulfur-in-Oil Analyzers
X-ray Analytical Microscope Super Large Chamber Model