HR-480

Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission)

HR-480 industrial residual chlorine meter takes sequential measurements of free residual chlorine, which is an indicator used in the inspection of the anti-bacterial properties of drinking water and swimming pools.
The sensor(RS-1) combined with uses a galvanic method with no drive section, making it highly maintainable, and producing stable measurements over a long period.

Measuring range

Free residual chlorine concentration: 0 - 2 mg/L

 

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.
  • Ideal for managing water quality, for example of drinking water or swimming pools The HR-480 takes sequential measurements of free residual chlorine, which is an indicator used in the inspection of the anti-bacterial properties of drinking water and swimming pools.
  • Uses a galvanic cell method The galvanic cell method makes the sensors more maintainable than the polarographic method, meaning that there is no need to polish the sensors, allowing them to be used semi-permanently.
  • Can be installed on the same cell as pH electrodes, ORP electrodes and temperature sensors (Option: Sampling Rack SS-2, SS-3) As well as residual chlorine sensors, pH, ORP electrodes and temperature sensors can also be installed on the same cell, making it possible to construct a low-cost system.
  • Span correction is possible when measuring fluids with low concentrations Correction work can be carried out easily on-site, with no need to prepare a separate high-concentration correction fluid.
  • Uses lead-free solder To reduce the burden on the environment, lead-free solder has been used to mount the components on the printed circuit board.
Product nameIndustrial Residual Chlorine Meter
ModelHR-480
Measurement methodGalvanic cell method
Measuring range0 to 2 mg/L0.01 mg/L resolution (number of decimal places selectable between 1 and 2)
RepeatabilityWithin ±0.05 mg/L (with equivalent input)
LinearityWithin ±0.05 mg/L (with equivalent input)
Transmission
output
4 mA to 20 mA DC, input/output isolated type
Maximum load resistance 900 Ω
Transmission output range: freely selectable within the measurement range.
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
  Contact type: relay contact, SPDT (1c)
  Contact rating: 240 V AC, 3 A and 30 V DC, 3 A (resistance load)
  Contact function: selectable from upper/lower limit operation (ON/OFF control), alarm, and maintenance.
Calibration functionZero calibration (zero adjustment omissible)
Span calibration (calibration by compariing with DPD tester)
Transmission
output hold feature
Previous value hold
Optional value hold
Continuous
Selectable from the above (However, only the previous value hold is available in the
maintenance mode.)
Self-diagnosis
function
Calibration function
Zero error
Sensitivity error
Outside of the measuring range
Converter error
Ambient
temperature
−5℃ to 45℃
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
−25℃ to 65℃
Power supplyRated voltage 100 V AC to 240 V AC, 50/60 Hz, 10 VA (max)
StructureIndoor-use panel installation type
    Panel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20
Terminal: IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directive: EN61326-1
Low Voltage Directive: EN61010-1
FCC RuleFCC Part15
External
dimensions
48 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 400 g
Compatible sensorRS-1
Measuring targetFree residual chlorine
Water sample
requirements
pH6 to pH8 (constant)
Temperature 0℃ to 40℃ (constant)

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

HC-200F
HC-200F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Four-Wire Transmission)

HC-200NH
HC-200NH

Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)

HC-300F
HC-300F

Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)

HD-200
HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-200FL
HD-200FL

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)

HD-300
HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
HD-960L

Dissolved Oxygen Monitor in Low Concentration

HD-960LR
HD-960LR

Dissolved oxygen concentration monitor series for semiconductor manufacturing

HE-200C
HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
HE-480R(W)

Industrial resistivity meter

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount Type Resistivity Meter(Four-Wire Transmission, 2-channel)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-Channel Resistivity Meter

HD-200
HD-200

Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-300
HD-300

Field-installation Type Dissolved Oxygen Meter(Two-Wire Transmission, Membrane Type)

HD-480
HD-480

Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)

HD-960L
HD-960L

Dissolved Oxygen Monitor in Low Concentration

HD-960LR
HD-960LR

Dissolved oxygen concentration monitor series for semiconductor manufacturing

HE-200C
HE-200C

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-200H
HE-200H

Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For High-concentration)

HE-200R
HE-200R

Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)

HE-300C
HE-300C

Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)

HE-300R
HE-300R

Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)

HE-480C
HE-480C

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Low-concentration)

HE-480R
HE-480R

Panel-mount Type Resistivity Meter(Four-Wire Transmission)

HE-480R(W)
HE-480R(W)

Industrial resistivity meter

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
HE-960HI

Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity meter

HE-960R-GC(W)
HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount Type Resistivity Meter(Four-Wire Transmission, 2-channel)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-Channel Resistivity Meter

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
HF-SP-CU

2-channel High Precision HF Concentration Monitor

HO-200
HO-200

Field-installation Type ORP Meter (Four-Wire Transmission)

HO-300
HO-300

Field-installation Type ORP Meter (Two-Wire Transmission)

HO-480
HO-480

Panel-mount Type ORP Meter (Four-Wire Transmission)

HR-200
HR-200

Feild-installation Type Residual Chlorine Meter (Four-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)

HT-110
HT-110

Total Organic Carbon Monitor

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor

Corporate