HC-200F

현장설치형 불소이온측정기(4-Wire Transmission)

HC-200F는 불소이온전극(#1009)을 연결하여 시료수 내 불소이온을 검출합니다.
(총 불소는 검출하지 않습니다.)

반도체 FPD 및 유리 제조업체와 같은 공장의 폐수에서 불소 이온 모니터링에 적합 합니다.

- 측정 범위 : 0~10,000mg/L
- 온도 : 0 ~ 100℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Tough

  • Responds to harsh conditions at the site process
      Operating temperature range(Transmitter):-20 - 55℃
      Rated power supply voltage:AC 100 - 240 V ±10% 50/60 Hz
      Robust aluminum die cast (Protection code:IP65)
  • CE Marking and FCC Compliance suitable for use at overseas sites

 

Intelligence

  • 0 to 10,000 mg/L wide measurement range (10-range switching)
  • Convenient function to display liquid temperature at the same time(Transmission output available)
  • Sensor error can be detected immediately by self-diagnosis function
  • Designed to be environmentally friendly (Pb-free) in response to WEEE and RoHS

 

Easy maintenance

  • Easy to view big display
  • Easy operation
  • Calibration log memory
  • Screw terminals that do not fall off are used in the terminal block for wiring
Product name Fluoride ion meter
Model HC-200F
Electrode used with product Fluoride ion electrode
Measurement
range
Concentration 0 mg/L to 10000 mg/L (Display range: 0 mg/L to 11000 mg/L)
Available range options:
10000, 5000, 2000, 1000, 500, 200, 100, 50, 20.0, 10.0 mg/L
Temperature 0℃ to 100℃ (Display range: -20℃ to 130℃)
Display
resolution
Concentration 0.1 mg/L: 0.0 mg/L to 20.0 mg/L
1 mg/L: 0 mg/L to 200 mg/L
10 mg/L: 0 mg/L to 2000 mg/L
100 mg/L: 0 mg/L to 10000 mg/L
Temperature 0.1℃
Performance Concentration Repeatability Within ±7% of the full scale (response for equivalent input)
Linearity Within ±10% full scale (response for equivalent input)
Temperature Repeatability ±0.3℃ (response for equivalent input)
Linearity ±0.3℃ (response for equivalent input)
Transmission
output
Number of output points 2 (the negative terminals for transmission outputs are internally connected and at the same electric potential)
Output type 4 mA to 20 mA DC, input/output isolated type
Load resistance Max.: 900Ω
Linearity Within ±0.08 mA (output only)
Repeatability Within ±0.02 mA (output only)
Output range Output 1 Concentration: Selection from preset ranges or free range input within measuring range.
Output 2 Temperature: Free setting within a range between -20℃ and 130℃
Occasional out for error Hold or burnout to either 3.8 mA or 21 mA
Transmission hold In the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact output Number of output points 3 points
Output type No-voltage contact output
Contact type Relay contact, SPDT (1c)
Output capacity 250 V AC 3 A, 30 V DC 3 A (resistance load)
Contact
function
R1, R2 Selectable from upper limit alarm, lower limit alarm, ON/OFF control,currently holding of transmission output, and cleaning output (The contact is closed during alarm operation, opened normally and while the power is down).
FAIL Error alarm (Closed in the normal state, opened in the failure state or while the power is down.)
Alarm setting range
  • Setting range: within a measuring range
  • Delay time: 0 seconds to 600 seconds
Control setting range
  • Setting range: within a measuring range
  • Control width: 2 mg/L to 40% of the setting range
Cleaning output Number of output points 1
Output type Contact output with voltage (output of connected power supply voltage)
Contact type Relay contact; SPST (1a)
Contact capacity 250 V AC 0.5 A
Contact function Actuation of solenoid valve for cleaning
Settings Cleaning period 0.1 hours to 168.0 hours
Cleaning time 2 seconds to 600 seconds
Hold time 2 seconds to 600 seconds
Timer accuracy Within 2 minutes per month
Description of cleaning
operation
  • Operation of internal timer
  • Operation of internal timer and external input
  • Enable the internal timer only when external input is active.
  • Choose one of the cleaning start signals (when this signal is ON for 2 seconds minimum, the internal cleaning sequence starts).
Contact input Number of input points 1
Contact type No-voltage “a” contact of open collector
Conditions ON resistance: 100Ωmax.
Open voltage: 24 V DC
Short-circuit current: 12 mA DC max.
Contact function External input for cleaning or transmission holding if cleaner is not attached.
Transmission
capability
Communication type RS-485
Signal type 2 wire system, isolated from the input circuit
Not isolated from transmission circuit
Temperature
compensation
Applicable temperature element Platinum resistor: 1 kΩ (0℃)
Positive relation resistor with temperature: 10 kΩ (25℃)
measurement range of temperature 0℃ to 100℃
Temperature calibration 1 point calibration comparing reference thermometer
Calibration Number of calibration points Selectable from 1, and 2 points
Kinds of standard solutions The first point: Calibrated by the standard solution with the density from 50% to 100% of the measuring range.
The second point: Calibrated by the standard solution with the density from 1% to 20% of the measuring range.
Additional capabilities Automatic detection of calibration failure (asymmetry potential,sensitivity, or response time)
Calibration history (asymmetry potential, sensitivity, and number of days elapsed after last calibration)
Self-check Calibration error Asymmetry potential error, and sensitivity error
Temperature calibration error
Electrode diagnostic error Temperature sensor short-circuit, temperature sensor disconnection,and out of the temperature measurement range
Converter error CPU error, ADC error, and memory errors
Operating temperature range -20℃ to 55℃ (without freeze)
Operating humidity range Relative humidity: 5% to 90% (without condensation)
Storage temperature -25℃ to 65℃
Power supply Rated power supply voltage 100 V to 240 V AC ±10% 50/60 Hz
Power consumption 15 VA (max)
Others With power switch for maintenance use
Compatible
standards
CE marking EMC  :EN61326-1
    Class A, Indrial electromagnetic environmentust
Safety :EN61010-1
RoHS  :EN50581
    9. Industrial monitoring and control instruments
FCC rules Part15 Class A
Structure Installation Outdoor installation type
Installation method Mounted on 50 A pole or wall
Protection code IP65
Case material Aluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittings SUS304
Material of hood SUS 304 stainless steel
(coated with epoxy-denatured melamine resin)
Material of window Polycarbonate
Display element Reflective monochrome LCD
External dimensions 180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
Mass Main body: Approx. 3.5 kg
Cover and mounting brackets: Approx. 1 kg

*:  When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

Note

An arrester (spark over voltage: 400 V) is implemented for transmission output, contact input, and communication. However, use a most suitable surge absorption element on the connection lines in accordance with the ambient environment, the situation of equipment installed, and the externally connected equipment.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

CS-620F
CS-620F

광섬유형 고온 인산 농도 모니터

CS-900
CS-900

비접촉 화학물질 농도 모니터

HC-200F
HC-200F

현장설치형 불소이온측정기(4-Wire Transmission)

HC-300F
HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HD-200
HD-200

현장설치형 용존산소측정기(4-Wire Transmission), 멤브레인형)

HD-200FL (Four-Wire Transmission, 광학식)
HD-200FL (Four-Wire Transmission, 광학식)

현장 설치형 용존 산소 측정기

HD-300
HD-300

현장설치형 용존산소측정기(2-Wire Transmission), 멤브레인 형)

HD-480
HD-480

용존산소측정기(4-Wire Transmission), 멤브레인 형)

HD-960L
HD-960L

저농도 용존 산소 모니터

HD-960LR
HD-960LR

용존 산소 농도 모니터

HE-200C
HE-200C

현장설치형 전기전도도계(4-Wire Transmission, 저농도용)

HE-200H
HE-200H

현장설치형 전기전도도계(4-Wire Transmission, 고농도용)

HE-200R
HE-200R

현장 설치형 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

현장 설치형 전기전도도계 (2-Wire Transmission, 저농도용)

HE-300C-IS ( 방폭형 )
HE-300C-IS ( 방폭형 )

방폭형 설치 타입 COND meter ( Low concentrtion )

HE-300R
HE-300R

현장 설치형 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

패널 장착형 전도도계(4-Wire Transmission, 저농도용)

HE-480C-GC
HE-480C-GC

카본 센서 전도도계 (저농도형)

HE-480H
HE-480H

패널 장착형 전도도계(4-Wire Transmission,저농도용)

HE-480H-DC24V
HE-480H-DC24V

판넬 장착형 전도도계(4-wire Transmitter , 고전도도용)

HE-480R
HE-480R

패널 장착형 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

구연산 모니터

HE-960CW
HE-960CW

패널 장착형 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH 모니터

HE-960H-TM-S
HE-960H-TM-S

고정밀 TMAH 농도 모니터

HE-960HC
HE-960HC

카본 센서 전도도계 (고농도형)

HE-960HI
HE-960HI

패널 장착형 전도도계(4-Wire Transmission, 광역용)

HE-960LC
HE-960LC

카본 센서 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 카본 센서 전도도계

HE-960RW
HE-960RW

패널 장착형 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 저항률계

HO-480
HO-480

패널 장착형 ORP 미터 (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

현장 설치형 pH Meter

HP-300
HP-300

현장 설치형 pH미터 (2-Wire Transmission)

HP-480
HP-480

패널 장착형 pH미터 (4-Wire Transmission)

HP-480PL
HP-480PL

패널 장착형 pH 미터(4-Wire Transmission, 펄스 비례 제어)

HP-480TP
HP-480TP

패널 장착형 pH 미터(4-Wire Transmission, 산업용 시분할 비례제어)

HP-960FTP
HP-960FTP

패널 장착형 pH 미터(4-Wire Transmission, 4 포인트 알람, 시분할 비례 제어)

HR-200
HR-200

현장 설치형 잔류염소 측정기 (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

현장 설치형 잔류 염소 측정기 (4-Wire Transmission, Rotating Type)

HR-480
HR-480

잔류 염소 측정기 (4-Wire Transmission)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

SLIA-300
SLIA-300

고감도 실리카 분석기

SLIA-5000
SLIA-5000

실리카 측정기

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

UP-100
UP-100

마이크로 볼륨 pH 모니터

HC-200F
HC-200F

현장설치형 불소이온측정기(4-Wire Transmission)

HC-300F
HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

현장 설치형 pH Meter

HP-300
HP-300

현장 설치형 pH미터 (2-Wire Transmission)

HP-480
HP-480

패널 장착형 pH미터 (4-Wire Transmission)

HP-480PL
HP-480PL

패널 장착형 pH 미터(4-Wire Transmission, 펄스 비례 제어)

HP-480TP
HP-480TP

패널 장착형 pH 미터(4-Wire Transmission, 산업용 시분할 비례제어)

HP-960FTP
HP-960FTP

패널 장착형 pH 미터(4-Wire Transmission, 4 포인트 알람, 시분할 비례 제어)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

T1 - TOCADERO Series
T1 - TOCADERO Series

온라인 TOC 분석기

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기

UP-100
UP-100

마이크로 볼륨 pH 모니터

Corporate