HP-480PL

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด)

์‚ฐ์—…์šฉ pH ๋ฏธํ„ฐ๋Š” ํŽ„์Šค ํŽŒํ”„๋ฅผ ์ง์ ‘ ๊ตฌ๋™ํ•  ์ˆ˜ ์žˆ๋Š” ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด ๊ธฐ๋Šฅ์ด ์žˆ๋Š” pH ๋ฏธํ„ฐ์ž…๋‹ˆ๋‹ค.
pH ์„ผ์„œ๋ฅผ ์—ฐ๊ฒฐํ•˜์—ฌ ์‹œ๋ฃŒ์ˆ˜์˜ pH์™€ ์˜จ๋„๋ฅผ ์ธก์ • ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.
 
HP-480PL์€ ํŽ„์Šค๋‹น ์ฃผ์ž… ๋ถ„ํ•ด๋Šฅ์ด ๋†’๊ธฐ ๋•Œ๋ฌธ์— pH ๊ฐ’์˜ ๋ฏธ์„ธ ์ œ์–ด๋ฅผ ํฌํ•จํ•˜๋Š” ์ฒ˜๋ฆฌ ์‹œ์Šคํ…œ์˜ ์ผ๋ถ€๋กœ ํŽ„์Šค ํŽŒํ”„๋ฅผ ์ œ์–ดํ•˜๋Š” ๋ฐ ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค(์˜ˆ: ๋ฏธ์‹œ์  ๋˜๋Š” ์ž‘์€ ์ƒ˜ํ”Œ์˜ pH ๊ฐ’ ์ œ์–ด).

์ธก์ • ๋ฒ”์œ„

pH : 0 ~ 14
์˜จ๋„ : 0 ~ 100 โ„ƒ

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.
  • Pulse proportional control function
    A pulse signal proportional to the set pH value is output.
    This signal can be input directly into a pulse pump, making it possible to construct a simple system with an excellent cost-performance ratio.
  • Maximum pulse output of 360 SPM
    A maximum of 360 pulses per minute can be output.
    It has a high insertion resolution per pulse, allowing for very fine control of pH values.
  • Compatible with five types of temperature compensation element
    Five types of temperature compensation element are supported: 500 ฮฉ, 6.8 kฮฉ, 1 kฮฉ, 10 kฮฉ and 350 ฮฉ.
  • Easy pH correction
    After immersing the pH electrodes in the standard fluid, simply follow the instructions displayed and press the ENT key.
    The automatic correction process is plain and simple.
  • A line-up of lead-free pH electrodes
    Uses lead-free glass. In addition, almost all sections of the pH electrodes, including lead wires and soldered junctions are lead-free.
  • Uses lead-free solder
    To reduce the burden on the environment, lead-free solder has been used to mount the components on the printed circuit board.
Product namePulse proportional control pH meter for industrial use
ModelHP-480PL
Measuring range0 pH to 14 pH: 0.01 pH resolution.
Temperature 0โ„ƒ to 100โ„ƒ: 1โ„ƒ resolution (selectable display).
Transmission
output
4 mA to 20 mA DC: input/output isolated type
Maximum load resistance: 900 ฮฉ
Transmission
output range
Free
Repeatability and
linearity
ยฑ0.05 pH, ยฑ0.08 mA (for transmission output range of 0 pH to 14 pH)
Contact outputOutputs: 2 points
Alarm contact output (R1 and R2)
โ€ƒโ€ƒContact type: relay contact, SPDT (1c)
โ€ƒโ€ƒContact rating: 240 V AC, 0.3 A and 30 V DC, 0.3 A (resistance load)
โ€ƒโ€ƒContact function: selectable from upper/lower limit operation (ON/OFF control), alarm, and maintenance.
Control actionsON/OFF control
  • Upper/lower limit setting range: 0.00 pH to 14.00 pH
  • Control width: 0.00 to 4.00 pH (ยฑ0.00 pH to ยฑ2.00 pH)
Pulse proportional
control
  • Upper/lower limit setting range: 0.00 pH to 14.00 pH
  • Maximum number of pulse output: Freely selectable in the range of
    1 SPM to 360 SPM.
  • Proportional band: 0.01 pH to 4.00 pH
  • Control output shift function: 0% to 50%
Calibration functionTwo-point automatic calibration or manual calibration
Two-point automatic calibration: with automatic validation of the electrode characteristics.
โ€ƒโ€ƒTypes of standard solution: pH 2, pH 4, pH 7, pH 9 and pH 10 (JIS)
โ€ƒโ€ƒCombination of standard solutions: pH 7 and one of the others
โ€ƒโ€ƒManual calibration: Freely selectable, but the difference should be over 2 pH.
Temperature calibration (one point).
Transmission
output hold feature
  • Previous value hold
  • Optional value hold
  • Continuous
    Selectable from the above (However, only the previous value hold is available in the maintenance mode).
Self-diagnosis
function
  • Calibration function
    Asymmetry potential error, sensitivity error, response speed error and standard solution error.
  • Electrode self-diagnosis
    Temperature sensor short-circuit and temperature sensor disconnection.
  • Outside of the measuring range.
  • Converter error.
Temperature
compensation
element

Selectable from compensation ON (350ฮฉ (25โ„ƒ), 500ฮฉ (25โ„ƒ),1 kฮฉ (0โ„ƒ)6.8 kฮฉ (25โ„ƒ) and 10 kฮฉ (25โ„ƒ)) and compensation OFF.

Temperature-
compensated
range
0โ„ƒ to 100โ„ƒ
Ambient
temperature
โˆ’5โ„ƒ to 45โ„ƒ
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
โˆ’25โ„ƒ to 65โ„ƒ
Power supplyRated voltage 100 V AC to 240 V AC, 50 Hz/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
Panel case: ABS, Terminal: PBT
Panel: water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal: IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
FCC RuleFCC Part15
External
dimensions
48 (W)  ร— 96 (H)  ร— 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 400 g

์ œํ’ˆ ๋ฌธ์˜

HORIBA์ œํ’ˆ์˜ ์ž์„ธํ•œ ์ •๋ณด๋ฅผ ์›ํ•˜์‹œ๋ฉด, ์•„๋ž˜์˜ ์–‘์‹์— ๋‚ด์šฉ์„ ์ž…๋ ฅ์„ ๋ถ€ํƒ๋“œ๋ฆฝ๋‹ˆ๋‹ค.

* ๋Š” ํ•„์ˆ˜์ž…๋ ฅํ•ญ๋ชฉ์ž…๋‹ˆ๋‹ค.

Related products

CS-620F
CS-620F

๊ด‘์„ฌ์œ ํ˜• ๊ณ ์˜จ ์ธ์‚ฐ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

CS-900
CS-900

๋น„์ ‘์ด‰ ํ™”ํ•™๋ฌผ์งˆ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HC-200F
HC-200F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(4-Wire Transmission)

HC-300F
HC-300F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(2-Wire Transmission)

HD-200
HD-200

ํ˜„์žฅ์„ค์น˜ํ˜• ์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(4-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธํ˜•)

HD-200FL (Four-Wire Transmission, ๊ด‘ํ•™์‹)
HD-200FL (Four-Wire Transmission, ๊ด‘ํ•™์‹)

ํ˜„์žฅ ์„ค์น˜ํ˜• ์šฉ์กด ์‚ฐ์†Œ ์ธก์ •๊ธฐ

HD-300
HD-300

ํ˜„์žฅ์„ค์น˜ํ˜• ์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(2-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธ ํ˜•)

HD-480
HD-480

์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(4-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธ ํ˜•)

HD-960L
HD-960L

์ €๋†๋„ ์šฉ์กด ์‚ฐ์†Œ ๋ชจ๋‹ˆํ„ฐ

HD-960LR
HD-960LR

์šฉ์กด ์‚ฐ์†Œ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HE-200C
HE-200C

ํ˜„์žฅ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„(4-Wire Transmission, ์ €๋†๋„์šฉ)

HE-200H
HE-200H

ํ˜„์žฅ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„(4-Wire Transmission, ๊ณ ๋†๋„์šฉ)

HE-200R
HE-200R

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ €ํ•ญ๊ณ„(4-Wire Transmission)

HE-300C
HE-300C

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„ (2-Wire Transmission, ์ €๋†๋„์šฉ)

HE-300C-IS ( ๋ฐฉํญํ˜• )
HE-300C-IS ( ๋ฐฉํญํ˜• )

๋ฐฉํญํ˜• ์„ค์น˜ ํƒ€์ž… COND meter ( Low concentrtion )

HE-300R
HE-300R

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ €ํ•ญ๊ณ„(2-Wire Transmission)

HE-480C
HE-480C

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, ์ €๋†๋„์šฉ)

HE-480C-GC
HE-480C-GC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„ (์ €๋†๋„ํ˜•)

HE-480H
HE-480H

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission,์ €๋†๋„์šฉ)

HE-480H-DC24V
HE-480H-DC24V

ํŒ๋„ฌ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-wire Transmitter , ๊ณ ์ „๋„๋„์šฉ)

HE-480R
HE-480R

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ €ํ•ญ๊ณ„(4-Wire Transmission)

HE-960CA
HE-960CA

๊ตฌ์—ฐ์‚ฐ ๋ชจ๋‹ˆํ„ฐ

HE-960CW
HE-960CW

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, 2์ฑ„๋„)

HE-960H-KOH
HE-960H-KOH

KOH ๋ชจ๋‹ˆํ„ฐ

HE-960H-TM-S
HE-960H-TM-S

๊ณ ์ •๋ฐ€ TMAH ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HE-960HC
HE-960HC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„ (๊ณ ๋†๋„ํ˜•)

HE-960HI
HE-960HI

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, ๊ด‘์—ญ์šฉ)

HE-960LC
HE-960LC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

ํ‰ํƒ„ ์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„

HE-960RW
HE-960RW

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ €ํ•ญ๊ณ„(4-Wire Transmission, 2์ฑ„๋„)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-์ฑ„๋„ ์ €ํ•ญ๋ฅ ๊ณ„

HO-480
HO-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• ORP ๋ฏธํ„ฐ (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ํ˜„์žฅ ์„ค์น˜ํ˜• pH Meter

HP-300
HP-300

ํ˜„์žฅ ์„ค์น˜ํ˜• pH๋ฏธํ„ฐ (2-Wire Transmission)

HP-480
HP-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH๋ฏธํ„ฐ (4-Wire Transmission)

HP-480PL
HP-480PL

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด)

HP-480TP
HP-480TP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ์‚ฐ์—…์šฉ ์‹œ๋ถ„ํ•  ๋น„๋ก€์ œ์–ด)

HP-960FTP
HP-960FTP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, 4 ํฌ์ธํŠธ ์•Œ๋žŒ, ์‹œ๋ถ„ํ•  ๋น„๋ก€ ์ œ์–ด)

HR-200
HR-200

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ž”๋ฅ˜์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ž”๋ฅ˜ ์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission, Rotating Type)

HR-480
HR-480

์ž”๋ฅ˜ ์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

TW-100
TW-100

์ž๋™ ์ˆ˜์งˆ ์ธก์ •์žฅ์น˜

TW-150
TW-150

Online Water Quality Monitor (๊ณต์ • ์ˆ˜์งˆ ์ธก์ • ์‹œ์Šคํ…œ)

U-50 Series
U-50 Series

๋‹คํ•ญ๋ชฉ ์ˆ˜์งˆ ์ธก์ •๊ธฐ

UP-100
UP-100

๋งˆ์ดํฌ๋กœ ๋ณผ๋ฅจ pH ๋ชจ๋‹ˆํ„ฐ

HC-200F
HC-200F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(4-Wire Transmission)

HC-300F
HC-300F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(2-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ํ˜„์žฅ ์„ค์น˜ํ˜• pH Meter

HP-300
HP-300

ํ˜„์žฅ ์„ค์น˜ํ˜• pH๋ฏธํ„ฐ (2-Wire Transmission)

HP-480
HP-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH๋ฏธํ„ฐ (4-Wire Transmission)

HP-480PL
HP-480PL

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด)

HP-480TP
HP-480TP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ์‚ฐ์—…์šฉ ์‹œ๋ถ„ํ•  ๋น„๋ก€์ œ์–ด)

HP-960FTP
HP-960FTP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, 4 ํฌ์ธํŠธ ์•Œ๋žŒ, ์‹œ๋ถ„ํ•  ๋น„๋ก€ ์ œ์–ด)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

T1 - TOCADERO Series
T1 - TOCADERO Series

์˜จ๋ผ์ธ TOC ๋ถ„์„๊ธฐ

TW-100
TW-100

์ž๋™ ์ˆ˜์งˆ ์ธก์ •์žฅ์น˜

TW-150
TW-150

Online Water Quality Monitor (๊ณต์ • ์ˆ˜์งˆ ์ธก์ • ์‹œ์Šคํ…œ)

U-50 Series
U-50 Series

๋‹คํ•ญ๋ชฉ ์ˆ˜์งˆ ์ธก์ •๊ธฐ

UP-100
UP-100

๋งˆ์ดํฌ๋กœ ๋ณผ๋ฅจ pH ๋ชจ๋‹ˆํ„ฐ

Corporate