HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HC-300F는 불소이온전극(#1009)을 연결하여 시료수 내 유리불소이온을 검출합니다.
(총 불소는 검출하지 않습니다.)
반도체 FPD 및 유리 제조업체와 같은 공장의 폐수에서 불소 이온 모니터링에 적합 합니다.

- 측정 범위 : 0~10,000mg/L
- 온도 : 0 ~ 100℃

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Tough

  • Responds to harsh conditions at the site process
      Operating temperature range(Transmitter):-20 - 60℃
      Rated voltage: DC 24 V
      Robust aluminum die cast  (Protection code:IP65)
  • CE Marking and FCC Compliance suitable for use at overseas sites

 

Intelligence

  • 0 to 10,000 mg/L wide measurement range (10-range switching)
  • Convenient function to display liquid temperature at the same time(Transmission output available)
  • Sensor error can be detected immediately by self-diagnosis function
  • Designed to be environmentally friendly (Pb-free) in response to WEEE and RoHS

 

Easy maintenance

  • Easy to view big display
  • Easy operation
  • Calibration log memory
  • Screw terminals that do not fall off are used in the terminal block for wiring

Converter rating

Product nameFluoride ion meter
ModelHC-300F
Measurable range0 mg/L to 10000 mg/L (Display range: 0 mg/L to 11000 mg/L)
Available range options:
10000, 5000, 2000, 1000, 500, 200, 100, 50, 20.0, 10.0 mg/L
0℃ to 100℃ (Display range: -20℃ to 130℃)
Display
resolution
Concentration0.1 mg/L: 0.0 mg/L to 20.0 mg/L
1 mg/L: 0 mg/L to 200 mg/L
10 mg/L: 0 mg/L to 2000 mg/L
100 mg/L: 0 mg/L to 10000 mg/L
Temperature0.1℃
PerformanceConcentrationRepeatabilityWithin ±7% of the full scale (response for equivalent input)
LinearityWithin ±10% full scale (response for equivalent input)
TemperatureRepeatability±0.3℃ (response for equivalent input)
Linearity±0.3℃ (response for equivalent input)
Transmission
output
Output type4 mA to 20 mA DC, input/output isolated type
Load resistanceMax. 600Ω (case of 24 V DC power supply)*1
LinearityWithin ±0.08 mA (output only)
RepeatabilityWithin ±0.02 mA (output only)
Output rangeConcentration: Selection from preset ranges or free range input within measuring range.
Occasional out for errorHold or burnout to either 3.8 mA or 21 mA
Transmission holdIn the maintenance mode, transmission signal is held at the latest value or preset value.
In the calibration mode, transmission signal can be alive or held.
Contact inputNumber of input points1
Contact typeNo-voltage a contact for open collector
ConditionsON resistance: 40Ω
Open voltage: 1.2 V DC
Short-circuit current: 21 mA DC max.
Contact functionExternal input for transmission holding.
Temperature
compensation
Applicable temperature elementPlatinum resistor: 1 kΩ (0℃)
Positive relation resistor with temperature: 10 kΩ (25℃)
0℃ to 100℃
Temperature calibration1 point calibration comparing reference thermometer
CalibrationNumber of calibration pointsSelectable from 1, and 2 points
Kinds of standard solutionsThe first point: Calibrated by the standard solution with the density from
50 to 100% of the measuring range.
The second point: Calibrated by the standard solution with the density
from 1 to 20% of the measuring range.
Additional capabilitiesAutomatic detection of calibration failure (asymmetry potential,
sensitivity, or response time)
Calibration history (asymmetry potential, sensitivity, and number of days elapsed after last calibration)
Self-checkCalibration errorAsymmetry potential error, and sensitivity error
Temperature calibration error
Electrode diagnostic errorTemperature sensor short-circuit, temperature sensor disconnection,and out of the temperature measurement range
Meter errorCPU error, ADC error, and memory errors
Operating temperature range-20℃ to 60℃ (without freeze)
Operating humidity rangeRelative humidity: 5% to 90% (without condensation)
Storage temperature-25℃ to 65℃
Power supplyRated voltage24 V DC (operating voltage range: 21 V to 32 V DC)*1
Power consumption0.6 W (Max)
Compatible
standards
CE markingEMC directive: EN61326-1
RoHS Directive: EN50581
EMCImmunity
Industrial
electromagnetic
environment
Electrostatic dischargeIEC61000-4-2
Electromagnetic field at radiated radio frequencyIEC61000-4-3
Electric fast transient/burstIEC61000-4-4
SurgeIEC61000-4-5*2
Conducted interference induced by radio
frequency
IEC61000-4-6
Emission
Class A
Radiated disturbanceCISPR 11 CLASS A
FCC rulesPart15 Class A
StructureInstallationOutdoor installation type
Installation methodMount on 50 A pole or wall
Protection codeIP65IEC60529, JIS C 0920
Case materialAluminum alloy (coated with epoxy-denatured melamine resin)
Material of fittingsSUS304
Material of hoodSUS 304 stainless steel
(coated with epoxy-denatured melamine resin)
Material of windowPolycarbonate
Display elementReflective monochrome LCD
External dimensions180 (W) × 155 (H) × 115 (D) mm (excluding mounting brackets)
MassMain body: Approx. 2.8 kg; cover and mounting brackets: Approx. 1 kg

 

*1: The max. load resistance is available within the range shown in the figure below, depending on power supply voltage:

Relation between power supply voltage and load resistance

*2: When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

Note

For transmission output, an arrester (spark-over voltage: 400 V) is implemented. However, use the optimal surge absorption element on the connection line in accordance with the ambient environment, equipment installation situation, externally connection equipment, and others.

 

Electrode rating

Product nameFluoride ion electrode
Model1009
Sample water
conditions
pH range4pH to 8pH (at 0.2 mg/L)
4pH to 10pH (at 20 mg/L)
4pH to 12pH (at 2000 mg/L)
Temperature range0℃ to 40℃
Electric conductivity500 μs/cm or more
Flow rate range1 cm/sec to 20 cm/sec
Electrode structureStructureSubmersible type
Response filmLanthanum fluoride
Comparative electrodeAg/AgCl, Internal solution KCL3.3 mol/L, Replenishment type
Liquid junctionCeramic double junction
Temperature
compensation element
Pt1000 Ω (0℃)
Cable length5 m
External dimensions12φ mm × 175 (L) mm (cable and projection excluded)
MassApprox. 200 g
OptionHolderCH-10 (Immersion type holder)
CF-30 (Inline type holder)
Cleaning deviceJCH-12 (Immersion type water-jet cleaning device)
JCH-32 (Circulation type water-jet cleaning device)

 

Note

  • This monitor detects the free fluoride ions in liquids, but it does not detect all fluorides. When complexes are present, a measurement lower than JIS will result.
  • Measurements may vary depending upon the pH level. Use this monitor in close to neutral pH conditions.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

CS-620F
CS-620F

광섬유형 고온 인산 농도 모니터

CS-900
CS-900

비접촉 화학물질 농도 모니터

HC-200F
HC-200F

현장설치형 불소이온측정기(4-Wire Transmission)

HC-300F
HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HD-200
HD-200

현장설치형 용존산소측정기(4-Wire Transmission), 멤브레인형)

HD-200FL (Four-Wire Transmission, 광학식)
HD-200FL (Four-Wire Transmission, 광학식)

현장 설치형 용존 산소 측정기

HD-300
HD-300

현장설치형 용존산소측정기(2-Wire Transmission), 멤브레인 형)

HD-480
HD-480

용존산소측정기(4-Wire Transmission), 멤브레인 형)

HD-960L
HD-960L

저농도 용존 산소 모니터

HD-960LR
HD-960LR

용존 산소 농도 모니터

HE-200C
HE-200C

현장설치형 전기전도도계(4-Wire Transmission, 저농도용)

HE-200H
HE-200H

현장설치형 전기전도도계(4-Wire Transmission, 고농도용)

HE-200R
HE-200R

현장 설치형 전기저항계(4-Wire Transmission)

HE-300C
HE-300C

현장 설치형 전기전도도계 (2-Wire Transmission, 저농도용)

HE-300C-IS ( 방폭형 )
HE-300C-IS ( 방폭형 )

방폭형 설치 타입 COND meter ( Low concentrtion )

HE-300R
HE-300R

현장 설치형 전기저항계(2-Wire Transmission)

HE-480C
HE-480C

패널 장착형 전도도계(4-Wire Transmission, 저농도용)

HE-480C-GC
HE-480C-GC

카본 센서 전도도계 (저농도형)

HE-480H
HE-480H

패널 장착형 전도도계(4-Wire Transmission,저농도용)

HE-480H-DC24V
HE-480H-DC24V

판넬 장착형 전도도계(4-wire Transmitter , 고전도도용)

HE-480R
HE-480R

패널 장착형 저항계(4-Wire Transmission)

HE-960CA
HE-960CA

구연산 모니터

HE-960CW
HE-960CW

패널 장착형 전도도계(4-Wire Transmission, 2채널)

HE-960H-KOH
HE-960H-KOH

KOH 모니터

HE-960H-TM-S
HE-960H-TM-S

고정밀 TMAH 농도 모니터

HE-960HC
HE-960HC

카본 센서 전도도계 (고농도형)

HE-960HI
HE-960HI

패널 장착형 전도도계(4-Wire Transmission, 광역용)

HE-960LC
HE-960LC

카본 센서 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 카본 센서 전도도계

HE-960RW
HE-960RW

패널 장착형 저항계(4-Wire Transmission, 2채널)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 저항률계

HO-480
HO-480

패널 장착형 ORP 미터 (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

현장 설치형 pH Meter

HP-300
HP-300

현장 설치형 pH미터 (2-Wire Transmission)

HP-480
HP-480

패널 장착형 pH미터 (4-Wire Transmission)

HP-480PL
HP-480PL

패널 장착형 pH 미터(4-Wire Transmission, 펄스 비례 제어)

HP-480TP
HP-480TP

패널 장착형 pH 미터(4-Wire Transmission, 산업용 시분할 비례제어)

HP-960FTP
HP-960FTP

패널 장착형 pH 미터(4-Wire Transmission, 4 포인트 알람, 시분할 비례 제어)

HR-200
HR-200

현장 설치형 잔류염소 측정기 (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

현장 설치형 잔류 염소 측정기 (4-Wire Transmission, Rotating Type)

HR-480
HR-480

잔류 염소 측정기 (4-Wire Transmission)

IT-470F-H
IT-470F-H

빌트인 타입 적외선 온도계

IT-545 Series
IT-545 Series

고정밀 적외선 온도계 (휴대용)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

SLIA-300
SLIA-300

고감도 실리카 분석기

SLIA-5000
SLIA-5000

실리카 측정기

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

UP-100
UP-100

마이크로 볼륨 pH 모니터

HC-200F
HC-200F

현장설치형 불소이온측정기(4-Wire Transmission)

HC-300F
HC-300F

현장설치형 불소이온측정기(2-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

현장 설치형 pH Meter

HP-300
HP-300

현장 설치형 pH미터 (2-Wire Transmission)

HP-480
HP-480

패널 장착형 pH미터 (4-Wire Transmission)

HP-480PL
HP-480PL

패널 장착형 pH 미터(4-Wire Transmission, 펄스 비례 제어)

HP-480TP
HP-480TP

패널 장착형 pH 미터(4-Wire Transmission, 산업용 시분할 비례제어)

HP-960FTP
HP-960FTP

패널 장착형 pH 미터(4-Wire Transmission, 4 포인트 알람, 시분할 비례 제어)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

T1 - TOCADERO Series
T1 - TOCADERO Series

온라인 TOC 분석기

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기

UP-100
UP-100

마이크로 볼륨 pH 모니터

Corporate