HP-960FTP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, 4 ํฌ์ธํŠธ ์•Œ๋žŒ, ์‹œ๋ถ„ํ•  ๋น„๋ก€ ์ œ์–ด)

์‚ฐ์—…์šฉ pH๋ฏธํ„ฐ๋Š” 4-Wire Transmission์„ ๊ฐ–์ถ˜ ๊ณ ์„ฑ๋Šฅ pH๋ฏธํ„ฐ์ž…๋‹ˆ๋‹ค.
pH ์„ผ์„œ๋ฅผ ์—ฐ๊ฒฐํ•˜์—ฌ ๊ฒ€์ˆ˜ ์ค‘ pH์™€ ์˜จ๋„๋ฅผ ์ธก์ •ํ•ฉ๋‹ˆ๋‹ค.
๋˜ํ•œ, ์™ธ๋ถ€ ์ž…๋ ฅ์„ ํ†ตํ•ด ์ฒญ์†Œ ์žฅ์น˜์™€ ์—ฐ๊ฒฐ๋  ์ˆ˜ ์žˆ์–ด ์ž๋™ ์ž‘๋™ ์‹œ๊ฐ„์„ ์—ฐ์žฅํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.
์ƒ˜ํ”Œ ์†์„ฑ๊ณผ ์ผ์น˜ํ•˜๋„๋ก ๋‹ค์–‘ํ•œ ์œ ํ˜•์˜ ์ „๊ทน ์‚ฌ์šฉ์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

์ธก์ • ๋ฒ”์œ„

pH: 0 ~ 14
์˜จ๋„ : 0 ~ 100โ„ƒ

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.
  • Time sharing proportional control function with F Zone
    Unlike commonly used time sharing proportional control functions, whose on-off frequency has generally been fixed, the HP-960FTP includes an control method called F Zone, whereby as the pH difference becomes smaller, it changes not just the time for which the pump injecting pH regulator is on, but also its frequency.
  • Four control outputs equipped
    You can set values of your choice for the upper and lower limits of the four control outputs, and switch them to either on-off control or time sharing proportional control.
  • Automatic diagnosis function for faults in electrode properties
    If there is an asymmetry potential, sensitivity or response speed in correction, the HP-960FTP automatically determines whether there is a fault in the pH electrodes, and displays an error message.
  • Can be linked with a cleaning device via an external input
    An input signal from a cleaning device can be used to put the output of the measurement value on hold.
  • Compatible with five types of temperature compensation elements
    Five types of temperature compensation element are supported: 500 ฮฉ, 6.8 kฮฉ, 1 kฮฉ, 10 kฮฉ and 350 ฮฉ.
  • Easy pH correction
    After immersing the pH electrodes in the standard fluid, simply follow the instructions displayed and press the ENT key.
    The automatic correction process is plain and simple.
  • A line-up of lead-free pH electrodes
    Uses lead-free glass. In addition, almost all sections of the pH electrodes, including lead wires and soldered junctions are lead-free.
  • Uses lead-free solder
    To reduce the burden on the environment, lead-free solder has been used to mount the components on the printed circuit board.
Product nameIndustrial pH meter
ModelHP-960FTP
Measuring range0 pH to 14 pH: 0.01 pH resolution.
Temperature 0โ„ƒ to 100โ„ƒ: 1โ„ƒ resolution (selectable display).
RepeatabilityWithinยฑ0.05 pH (Equivalent input)
linearityWithinยฑ0.05 pH (Equivalent input)
Transmission
output

4 mA to 20 mA DC, input/output isolated type
Maximum load resistance: 900 ฮฉ
Transmission output range: Free

Contact outputOutputs: 4 points
Alarm contact output (R1, R2, R3, and R4)
โ€ƒโ€ƒContact type: relay contact, SPDT (1c)
โ€ƒโ€ƒContact rating: 240 V AC 3 A and 30 V DC 3 A (resistance load)
โ€ƒโ€ƒContact function: selectable from upper/lower limit operation (ON/OFF control), alarm, and maintenance.
Contact inputInput: 1 point
Contact type: open collector, No-voltage contact
Contact function: external input for Hold operation
Control operations

ON/OFF control

  • Upper and lower limits setting range: 0.00 pH to 14.00 pH
  • Control width: 0.00 pH to 4.00 pH (ยฑ0.00 pH to ยฑ2.00 pH)
    Time-division proportional control
  • Upper and lower limits setting range: 0.00 pH to 14.00 pH
  • Proportional band: 0.00 pH to 4.00 pH
  • Cycle time: 5 s to 300 s
  • Control output shift capability: 0% to 50% of shift volume for the cycle time
  • Self-extending cycle time capability: The cycle time is extended automatically when the deviation value enters a set range (F zone) in proportion to the deviation value (This feature has no effect when the shift function has been enabled).
  • F zone: 1% to 100% of the proportional band (Self-extension of the cycle time starts working when the deviation enters the above range).
  • Upper limit for extending the cycle time: 0 s to 300 s.
  • Maximum control volume: 50% to 100% (To be applied regardless of whether the measured value is in the proportional band or not).
Calibration functionTwo-point automatic calibration or manual calibration.
Two-point automatic calibration: with automatic validation of the electrode characteristics.
โ€ƒโ€ƒTypes of standard solution: pH 2, pH 4, pH 7, pH 9 and pH 10 (JIS)
โ€ƒโ€ƒCombination of standard solutions: pH 7 and one of the others
โ€ƒโ€ƒManual calibration: Freely selectable, but the difference should be over 2 pH.
Temperature calibration (one point).
Transmission
output hold feature
Selectable from the previous value hold, the preset hold, or the continuous output (However, only the previous value hold is available in the maintenance mode.)
Self-diagnosis
function

Calibration function: Asymmetry potential error, sensitivity error, response speed error and standard solution error.
Electrode self-diagnosis: Temperature sensor short-circuit and temperature sensor disconnection.
Outside of the measuring range.
Converter error.

Temperature
detection
element

Selectable from compensation ON (350ฮฉ (25โ„ƒ), 500ฮฉ (25โ„ƒ),1 kฮฉ (0โ„ƒ)6.8 kฮฉ (25โ„ƒ) and 10 kฮฉ (25โ„ƒ)) and compensation OFF.

Temperature
compensated
range
0โ„ƒ to 100โ„ƒ
Ambient
temperature
โˆ’5โ„ƒ to 45โ„ƒ
Relative humidity20% to 85% (without dew condensation)
Storage
temperature
โˆ’25โ„ƒ to 65โ„ƒ
Power supplyRated voltage 100 V to 240 V AC, 50 Hz/60 Hz, 10 VA (max.)
StructureIndoor-use panel installation type
โ€ƒโ€ƒโ€ƒPanel case: ABS, Terminal: PBT
Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920)
Rear case: IP20, Terminal: IP00
Class II device (IEC61010-1)
Pollution level 2 (IEC61010-1)
Conforming
standards
CE MarkingEMC Directive: EN61326-1
Low Voltage Directive: EN61010-1
RoHS Directive: EN50581
Immunity
(Industrial electromagnetic environment)
Noise increase ยฑ0.05 pH or less
FCC RuleFCC Part15
External
dimensions
96 (W)  ร— 96 (H)  ร— 115 (D) mm
Case depth: approx. 105 mm
MassApprox. 550 g

์ œํ’ˆ ๋ฌธ์˜

HORIBA์ œํ’ˆ์˜ ์ž์„ธํ•œ ์ •๋ณด๋ฅผ ์›ํ•˜์‹œ๋ฉด, ์•„๋ž˜์˜ ์–‘์‹์— ๋‚ด์šฉ์„ ์ž…๋ ฅ์„ ๋ถ€ํƒ๋“œ๋ฆฝ๋‹ˆ๋‹ค.

* ๋Š” ํ•„์ˆ˜์ž…๋ ฅํ•ญ๋ชฉ์ž…๋‹ˆ๋‹ค.

Related products

CS-620F
CS-620F

๊ด‘์„ฌ์œ ํ˜• ๊ณ ์˜จ ์ธ์‚ฐ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

CS-900
CS-900

๋น„์ ‘์ด‰ ํ™”ํ•™๋ฌผ์งˆ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HC-200F
HC-200F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(4-Wire Transmission)

HC-300F
HC-300F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(2-Wire Transmission)

HD-200
HD-200

ํ˜„์žฅ์„ค์น˜ํ˜• ์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(4-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธํ˜•)

HD-200FL (Four-Wire Transmission, ๊ด‘ํ•™์‹)
HD-200FL (Four-Wire Transmission, ๊ด‘ํ•™์‹)

ํ˜„์žฅ ์„ค์น˜ํ˜• ์šฉ์กด ์‚ฐ์†Œ ์ธก์ •๊ธฐ

HD-300
HD-300

ํ˜„์žฅ์„ค์น˜ํ˜• ์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(2-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธ ํ˜•)

HD-480
HD-480

์šฉ์กด์‚ฐ์†Œ์ธก์ •๊ธฐ(4-Wire Transmission), ๋ฉค๋ธŒ๋ ˆ์ธ ํ˜•)

HD-960L
HD-960L

์ €๋†๋„ ์šฉ์กด ์‚ฐ์†Œ ๋ชจ๋‹ˆํ„ฐ

HD-960LR
HD-960LR

์šฉ์กด ์‚ฐ์†Œ ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HE-200C
HE-200C

ํ˜„์žฅ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„(4-Wire Transmission, ์ €๋†๋„์šฉ)

HE-200H
HE-200H

ํ˜„์žฅ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„(4-Wire Transmission, ๊ณ ๋†๋„์šฉ)

HE-200R
HE-200R

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ €ํ•ญ๊ณ„(4-Wire Transmission)

HE-300C
HE-300C

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ „๋„๋„๊ณ„ (2-Wire Transmission, ์ €๋†๋„์šฉ)

HE-300C-IS ( ๋ฐฉํญํ˜• )
HE-300C-IS ( ๋ฐฉํญํ˜• )

๋ฐฉํญํ˜• ์„ค์น˜ ํƒ€์ž… COND meter ( Low concentrtion )

HE-300R
HE-300R

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ „๊ธฐ์ €ํ•ญ๊ณ„(2-Wire Transmission)

HE-480C
HE-480C

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, ์ €๋†๋„์šฉ)

HE-480C-GC
HE-480C-GC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„ (์ €๋†๋„ํ˜•)

HE-480H
HE-480H

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission,์ €๋†๋„์šฉ)

HE-480H-DC24V
HE-480H-DC24V

ํŒ๋„ฌ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-wire Transmitter , ๊ณ ์ „๋„๋„์šฉ)

HE-480R
HE-480R

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ €ํ•ญ๊ณ„(4-Wire Transmission)

HE-960CA
HE-960CA

๊ตฌ์—ฐ์‚ฐ ๋ชจ๋‹ˆํ„ฐ

HE-960CW
HE-960CW

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, 2์ฑ„๋„)

HE-960H-KOH
HE-960H-KOH

KOH ๋ชจ๋‹ˆํ„ฐ

HE-960H-TM-S
HE-960H-TM-S

๊ณ ์ •๋ฐ€ TMAH ๋†๋„ ๋ชจ๋‹ˆํ„ฐ

HE-960HC
HE-960HC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„ (๊ณ ๋†๋„ํ˜•)

HE-960HI
HE-960HI

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ „๋„๋„๊ณ„(4-Wire Transmission, ๊ด‘์—ญ์šฉ)

HE-960LC
HE-960LC

์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

ํ‰ํƒ„ ์นด๋ณธ ์„ผ์„œ ์ „๋„๋„๊ณ„

HE-960RW
HE-960RW

ํŒจ๋„ ์žฅ์ฐฉํ˜• ์ €ํ•ญ๊ณ„(4-Wire Transmission, 2์ฑ„๋„)

HE-960RW-GC(W)
HE-960RW-GC(W)

2-์ฑ„๋„ ์ €ํ•ญ๋ฅ ๊ณ„

HO-480
HO-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• ORP ๋ฏธํ„ฐ (4-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ํ˜„์žฅ ์„ค์น˜ํ˜• pH Meter

HP-300
HP-300

ํ˜„์žฅ ์„ค์น˜ํ˜• pH๋ฏธํ„ฐ (2-Wire Transmission)

HP-480
HP-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH๋ฏธํ„ฐ (4-Wire Transmission)

HP-480PL
HP-480PL

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด)

HP-480TP
HP-480TP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ์‚ฐ์—…์šฉ ์‹œ๋ถ„ํ•  ๋น„๋ก€์ œ์–ด)

HP-960FTP
HP-960FTP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, 4 ํฌ์ธํŠธ ์•Œ๋žŒ, ์‹œ๋ถ„ํ•  ๋น„๋ก€ ์ œ์–ด)

HR-200
HR-200

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ž”๋ฅ˜์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission, Water flow beads)

HR-200RT
HR-200RT

ํ˜„์žฅ ์„ค์น˜ํ˜• ์ž”๋ฅ˜ ์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission, Rotating Type)

HR-480
HR-480

์ž”๋ฅ˜ ์—ผ์†Œ ์ธก์ •๊ธฐ (4-Wire Transmission)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

TW-100
TW-100

์ž๋™ ์ˆ˜์งˆ ์ธก์ •์žฅ์น˜

TW-150
TW-150

Online Water Quality Monitor (๊ณต์ • ์ˆ˜์งˆ ์ธก์ • ์‹œ์Šคํ…œ)

U-50 Series
U-50 Series

๋‹คํ•ญ๋ชฉ ์ˆ˜์งˆ ์ธก์ •๊ธฐ

UP-100
UP-100

๋งˆ์ดํฌ๋กœ ๋ณผ๋ฅจ pH ๋ชจ๋‹ˆํ„ฐ

HC-200F
HC-200F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(4-Wire Transmission)

HC-300F
HC-300F

ํ˜„์žฅ์„ค์น˜ํ˜• ๋ถˆ์†Œ์ด์˜จ์ธก์ •๊ธฐ(2-Wire Transmission)

HP-200 (Four-Wire Transmission)
HP-200 (Four-Wire Transmission)

ํ˜„์žฅ ์„ค์น˜ํ˜• pH Meter

HP-300
HP-300

ํ˜„์žฅ ์„ค์น˜ํ˜• pH๋ฏธํ„ฐ (2-Wire Transmission)

HP-480
HP-480

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH๋ฏธํ„ฐ (4-Wire Transmission)

HP-480PL
HP-480PL

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ํŽ„์Šค ๋น„๋ก€ ์ œ์–ด)

HP-480TP
HP-480TP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, ์‚ฐ์—…์šฉ ์‹œ๋ถ„ํ•  ๋น„๋ก€์ œ์–ด)

HP-960FTP
HP-960FTP

ํŒจ๋„ ์žฅ์ฐฉํ˜• pH ๋ฏธํ„ฐ(4-Wire Transmission, 4 ํฌ์ธํŠธ ์•Œ๋žŒ, ์‹œ๋ถ„ํ•  ๋น„๋ก€ ์ œ์–ด)

LAQUA PH210
LAQUA PH210

Handheld pH/ORP/Temperature Meter

T1 - TOCADERO Series
T1 - TOCADERO Series

์˜จ๋ผ์ธ TOC ๋ถ„์„๊ธฐ

TW-100
TW-100

์ž๋™ ์ˆ˜์งˆ ์ธก์ •์žฅ์น˜

TW-150
TW-150

Online Water Quality Monitor (๊ณต์ • ์ˆ˜์งˆ ์ธก์ • ์‹œ์Šคํ…œ)

U-50 Series
U-50 Series

๋‹คํ•ญ๋ชฉ ์ˆ˜์งˆ ์ธก์ •๊ธฐ

UP-100
UP-100

๋งˆ์ดํฌ๋กœ ๋ณผ๋ฅจ pH ๋ชจ๋‹ˆํ„ฐ

Corporate