MEXA-ONE

MEXA-ONE - Motor Exhaust Gas Analyzer
MEXA-ONE - Exhaust Test
MEXA-ONE - Nitrogen Compounds Measurement
MEXA-ONE - EGR Measurement
MEXA-ONE product picture

배기 가스 측정 장치

HORIBA Awarded “2012 Hardware Innovation of the Year Award” for MEXA-ONE Design

_________________________________________________

Reliable・Efficient・Expandable

HORIBA MEXA 시리즈는 전세계 차량 배기 가스 규제에 대응하기 위한 목적으로 배기 가스량을 측정하는 제품입니다. 또한 HORIBA MEXA-ONE 시리즈는 효율적 하드웨어, 소프트웨어 설계로 탄생한 HORIBA의 대표 배기가스 측정기로 HORIBA ONE PLATFORM 채택을 통해 사용자 제어의 최적화를 이끌어냈습니다.

Segment: Automotive
Manufacturing Company: HORIBA, Ltd.

 Increased Test Efficiency

MEXA-ONE incorporates HORIBA's leading-edge technology to enhance reliability and performance beyond today's expectations.
Improved durability and maintenance assure efficient test facility operation, reducing overall test duration and accelerating engine and vehicle development.

Faster Response and Shorter Test Times

Fully automated, customer-defined, pre-test routines ensure system readiness for testing. Overall test duration is minimized by reducing analyzer response and wait times between measurements.

  • 50% reduction in analyzer response times (t99) *
  • 30% reduction in analyzer calibration waiting times *
  • Optimization of analyzer purging times

* By comparison with HORIBA's conventional products

Lower Cost of Ownership

Savings are realized through reduced operational costs, with a focus on reduction of consumables and facility requirements.

  • 10% reduction in power consumption *
  • Filter element replacement is eliminated due to the use of the automatic purge function for the back flushing filter
  • 30% reduction in analyzer calibration gas consumption *

* By comparison with HORIBA's conventional products

Reduction in Consumables

Example
For a 12 hours per day operation and total of 200 days per year, the following savings in running cost can be achieved.
(This example is based on 10 systems)

Based on the condition of ;
・Calibration / zero and span check conducted every 2 hours
・Leak check conducted every 8 hours
・Filter element replaced every 4 hours

 Improved Test Facility Operation

Enhanced Maintenance Support

Ensuring Accurate Measurement

Automatic notifications of periodic inspections and adjustments are generated as required by emission regulations in accordance with a user-defined schedule. Inspections and adjustments can also be started from the control window.


                                                              QC Sequence

Preventative Maintenance Feature

This automatic function provides advanced notification for the replacement of consumable parts. This process enables proactive maintenance to be performed.

MEXA-ONE automatically monitors analyzer sensitivity and displays the request for readjustment before exceeding the permissible range.


                                                       Sensor Sensitivity Monitor

Effective Troubleshooting

When an alarm occurs, the MEXA-ONE not only displays details of the alarm but also generates a display with troubleshooting instructions. Quick alarm resolution enables effective testing.


Troubleshooting (Alarm Detail)

High Performance and Durability

MEXA-ONE exceeds the durability seen in about 4,500 MEXA-7000 units in operation around the world. For example, the entire sample handling system has undergone a major upgrade to optimize sample flow and to reduce pump load.

 Wide Application Range

Evaluation of NOx After-Treatment Catalyst Systems

Measurement of nitrogen compounds (NO, NO2, N2O, NH3) is essential for evaluation of NOx after-treatment systems. MEXA-ONE can be easily configured to provide optimum measurement capability based on the testing objective.

Close-Coupled Transient EGR Measurement

To deliver faster response and more accurate EGR measurement, MEXA-ONE incorporates new EGR sample handling and analysis in a compact cabinet.

Multi-point EGR Measurement

・Multi-point measurement can now be performed on complete EGR systems using MEXA-ONE's modular design.

HCHO/N2O Measurement

Overwhelmingly low-noise and high-accuracy Formaldehyde and N2O measurement in the low concentration range is realized by HORIBA's next generation infrared gas analysis technology IRLAMTM.

* IRLAM is a registered trademark or trademark of HORIBA, Ltd. in Japan and other countries


Click here for more information about IRLAM

Example of measurement results of formaldehyde (HCHO) in a vehicle exhaust gas test

MEXA-ONE System Line-up

MEXA-ONE is a flexible system allowing configuration for a wide range of applications.


※1 Oven is equipped with heated analyzers and Heated Sample-Handling System
※2 Analyzer for CO2 low measurement (AIA-22) is available
※3 Optional unit (HSPS-0X) is required
※4 Heated Filter with back flush purge is recommended

OPTION / FUNCTION

・Remote EGR (R-EGR-01)
・Remote EGR (R-EGR-02H)
・Remote Tracer (R-TR-01)

・Heated Filter with back flush purge (dual type) (F-02HB)
・Heated Filter with back flush purge (F-01HB)
・Heated Filter (F-01H)

・Span Gas Selector (SGS)
・Remote Multi Gas Controller (MGC-0XM)

・Gas Divider and Converter Checker Unit (high accurate type) (GDC-ONE)
・Gas Divider and Converter Checker Unit (GDC-703)
・Gas Divider and Converter Checker Unit (base model type) (GDC-Lite)
・Leak Checker (LCK-01)
・Heated Bubbler (HCU-700)

Standard

Measurement 
component
ModelAnalyzer unitPrinciple※1Range※2
COAIA-11Half 19 InchNDIR0-50 ~ 0-5000 ppm
COAIA-31Half 19 InchNDIR0-0.5 ~ 0-12 vol%
COAlA-41Half 19 InchNDIR0-3 ~ 0-20 vol%
CO2AlA-22Half 19 InchNDIR0-0.1 ~ 0-6 vol%
CO2AlA-32Half 19 InchNDIR0-0.5 ~ 0-20 vol%
CO2AlA-42Half 19 InchNDIR0-3 ~ 0-20 vol%
HCAlA-14Half 19 InchNDIR0-100 ~ 0-5000 ppm
HCAlA-34Half 19 InchNDIR0-5000 ~ 0-10000 ppm
N2OAlA-15Half 19 InchNDIR0-100 ~ 0-5000 ppm
O2MPA-01Half 19 InchMPD0-1 ~ 0-25 vol%
THCFIA-01Half 19 InchFID0-10 ~ 0-20000 ppmC
NO/NOxCLA-01Half 19 InchCLD0-10 ~ 0-10000 ppm
CH4GFA-01Half 19 InchGC-FID0-10 ~ 0-3000 ppm
THCFIA-01H19 InchHeated-FID0-10 ~ 0-60000 ppmC
THC,CH4,NMHCFIA-02H-NC19 Inch

Heated-FID
NMC-FID

THC 0-10 ~ 0-5000 ppmC
CH4 0-10 ~ 0-5000 ppm
NMHC is measured by dual detector
THC,CH4,NMHCFIA-02H-ND19 InchHeated-FID
NMC-FID
THC 0-50 ~ 0-60000 ppmC
CH4 0-50 ~ 0-25000 ppm
NMHC is measured by dual detector
NO/NOxCLA-01HV19 InchHeated-CLD0-10 ~ 0-10000 ppm
NO,NOx,No2CLA-02HV19 InchDual Heated-CLDNO 0-10 ~ 0-10000 ppm
NOx 0-10 ~ 0-10000 ppm
NO2 is measured by dual detector
THCFIA-01OOVNHeated-FID0-10 ~ 0-60000 ppmC
THC,CH4,NMHCFIA-02O-NCOVNHeated-FID
NMC-FID
THC 0-10 ~ 0-5000 ppmC
CH4 0-10 ~ 0-5000 ppm
NMHC is measured by dual detector
THC,CH4,NMHCFIA-02O-NDOVNHeated-FID
NMC-FID
THC 0-50 ~ 0-60000 ppmC
CH4 0-50 ~ 0-25000 ppm
NMHC is measured by dual detector
NO/NOxCLA-01OV-2OVNHeated-CLD0-10 ~ 0-10000 ppm
NO,NOxCLA-02OV-3OVNDual heated-CLDNO 0-10 ~ 0-10000 ppm
NOx 0-10 ~ 0-10000 ppm
NO2 is measured by dual detector
HCHOXLA-13H19 InchQCL-IR0-20~100 ppm

Low Emission Measurement

Measurement 
component
ModelAnalyzer unitPrinciple※1Range※2
COAIA-11SL19 InchNDIR0-10 ~ 0-1000 ppm
CO2AIA-22Half 19 InchNDIR0-0.1 ~ 0-6 vol%
THCFIA-01SLHalf 19 InchFID0-1 ~ 0-500 ppmC
NO/NOxCLA-01SLHalf 19 InchCLD0-1 ~ 0-500 ppm
CH4GFA-01SLHalf 19 InchGC-FID0-1 ~ 0-500 ppm
N2OXLA-11Half 19 InchQCL-IR0-0.5 ~ 0-20 ppm

Remote Type (Option)

Measurement 
component
ModelAnalyzer unitPrinciple※1Range※2
CO2R-EGR-01RemoteNDIR Dry 1Line0-10 ~ 0-20 vol%
CO2R-TR-01RemoteNDIR Dry 1Line0-10 ~ 0-20 vol%
CO2R-EGR-02HRemoteNDIR Wet 2Line0-10 ~ 0-20 vol%

※1
NDIR : Non Dispersive Infrared Detector
FID : Flame Ionization Detector
GC-FID : Flame lonization Detector with Gas Chromatography
NMC-FID : Flame lonization Detector with Non Methane Cutter
CLD : Chemiluminescence Detector
CLD[Wet/Dry] : Chemiluminescence Detector [Wet/Dry switchable]
MPD : Magnetopneumatic Detector
QCL-IR: Quantum Cascade Laser Infrared Detector

※2 Other ranges on request

System Specifications

  • Dimension
    -Standard 19 inch Rack・・・655(W) × 855(D) × 1970(H) mm
    -Oven Type Heated Analyzer・・・430(W) × 550(D) × 1100(H) mm
  • Mass・・・Depends on system (e.g. MEXA-ONE–D1(OVN-type) = Approx. 350 kg)
  • Ambient temperature・・・5 deg.C to 40 deg.C
  • Ambient humidity・・・80% or less as relative humidity
  • Ambient Pressure・・・80 kPa to 102 kPa (abs)
    (Altitude below 2000 m above sea-level)
RDE tests on the chassis dynamometer
RDE tests on the chassis dynamometer
Catalyst testing in automobiles and components
Catalyst testing in automobiles and components
Engine testing in automobiles and components
Engine testing in automobiles and components
Measuring vehicle emissions on a chassis dynamometer
Measuring vehicle emissions on a chassis dynamometer
To comply with newest emission legislation it is necessary to test vehicle emissions on chassis dynamometer with the corresponding driving cycles.
Particle Measurement in the Sub-23nm Range
Particle Measurement in the Sub-23nm Range
Concerns exist that advances in modern engine technology may contribute to large portions of solid particles at sizes smaller than 23nm. The EU Joint Research Center has confirmed this concern in several investigations.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

CVS-ONE
CVS-ONE

희석 배기가스 분석기

EXFM-ONE
EXFM-ONE

초음파 배기 유량계

FTIR 배기 가스 분석기 FTX-ONE-CS/RS
FTIR 배기 가스 분석기 FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

FTX-ONE-CL
FTX-ONE-CL

FTIR 배기 가스 분석기 희석 측정 타입

MDLT-ONE
MDLT-ONE

부분 희석 PM 샘플 장치

MEDAS
MEDAS

고도 시뮬레이터

MEXA-2000SPCS series
MEXA-2000SPCS series

배기가스 고체 입자 카운팅 시스템

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

레이저 분광 배기가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

OBS-ONE PM unit
OBS-ONE PM unit

차량 탑재형 배기가스 측정 장치

OBS-ONE PN Unit
OBS-ONE PN Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE SPN10 Unit
OBS-ONE SPN10 Unit

SPN10 분석용 차량 탑재형 배기가스 측정 장치

PFS-ONE
PFS-ONE

입자성 물질 필터 관리 시스템

STARS VETS
STARS VETS

배기가스 테스트용 테스트 자동화 시스템

51 series
51 series

방폭형 가스 분석기

AP-370 series
AP-370 series

Air Pollution Monitor

AQMS
AQMS

Ambient Air Quality Monitoring System

CEMS
CEMS

Continuous Emission Monitoring System

ENDA-5000 Series
ENDA-5000 Series

굴뚝 배출가스 분석장치

FTIR 배기 가스 분석기 FTX-ONE-CS/RS
FTIR 배기 가스 분석기 FTX-ONE-CS/RS

FTIR Exhaust Gas Analyzer Direct Measurement Type

FTX-ONE-CL
FTX-ONE-CL

FTIR 배기 가스 분석기 희석 측정 타입

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

MEXA-ONE-QL-NX
MEXA-ONE-QL-NX

레이저 분광 배기가스 측정 장치

NZ-3000
NZ-3000

지르코니아 산소 분석기

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

PG-300 시리즈
PG-300 시리즈

휴대용 가스분석기

Process
Process

Process Analyzer System

PX-375
PX-375

PM & 중금속 분석기

VA-5000
VA-5000

범용 멀티 가스 분석기

51 series
51 series

방폭형 가스 분석기

AP-370 series
AP-370 series

Air Pollution Monitor

EMGA-Expert
EMGA-Expert

산소/질소/수소 분석기

EMGA-Pro
EMGA-Pro

산소/질소/수소 분석기

EMIA-Expert
EMIA-Expert

탄소/황 분석기

EMIA-Pro
EMIA-Pro

탄소/유황 분석기

EMIA-Step
EMIA-Step

탄소/황 분석기 (인덕션 퍼니스 타입)

ENDA-5000 Series
ENDA-5000 Series

굴뚝 배출가스 분석장치

ENDA-7000 Series
ENDA-7000 Series

굴뚝 배출가스 분석장치

IR-200
IR-200

Gas Monitor for Chamber Cleaning End Point Monitoring

IR-400
IR-400

High-grade type Gas Monitor for Chamber Cleaning End Point Monitoring

LO-300
LO-300

레이저 스캔 오일 필름 검출기

MEXA-ONE
MEXA-ONE

배기 가스 측정 장치

OBS-ONE GS Unit
OBS-ONE GS Unit

차량 탑재형 배기가스 측정 장치

OBS-ONE IRLAM Unit
OBS-ONE IRLAM Unit

NH3/N2O 대응용 차량 탑재형 배기가스 측정 장치

OCMA-500
OCMA-500

폐수 오일 측정기

OCMA-550
OCMA-550

오일 농도 측정기

PG-300 시리즈
PG-300 시리즈

휴대용 가스분석기

VA-5000
VA-5000

범용 멀티 가스 분석기

Corporate