CFD-2G

Amplifier-Discriminator

The CFD-2G is a hybrid amplifier-discriminator module designed for use with a wide variety of single photon detectors. It is neatly packaged to allow positioning close to the detector in order to minimise signal degradation, and features USB interface for simplified configuration.

Segment: Scientific
Manufacturing Company: HORIBA Scientific

Each module features:

  • Amplifier with bandwidth up to 2GHz
  • Constant fraction discriminator (CFD)
  • Simultaneous NIM and TTL-compatible outputs
  • Detector overload protection (operates in conjunction with HV supply)
  • USB and F-link PC interfaces (control panel software included)
  • Programmable non-volatile settings for gain, threshold, walk, and trip count rate (USB cable may be removed once module is configured)
  • Visual LED indication of activity
  • 15V power requirement

The CFD-2G's unique combination of features makes it particularly well suited to applications involving low gain detectors where immunity to interference and signal degradation is a critical consideration.  Its compact dimensions permit it to be close-coupled to MCP and NIR detection modules keeping the connection between the detector and the amplifier very short.  Furthermore, since the amplifier and discriminator are on the same board, direct conversion to digital (NIM and TTL) means there is no requirement to expose the analogue amplifier output to an external connector.

A detector overload feature allows the programming of a count rate monitor threshold that can be used to deactivate the detector's high voltage supply in order to protect the detector from damage due to over-illumination.  This feature operates in conjunction with the HORIBA Scientific Fluoro3PS HV power supply.

The CFD-2G is available in 4 variants optimised for different types of detector:

Table

Model

PMT type

Risetime

Transit Time Spread (TTS)

CFD-2G-A

MCP-PMT (e.g. R3809 series)

100ps

25ps

CFD-2G-B

Fast risetime PMT (e.g. H10330 series)

<1ns

<500ps

CFD-2G-C

Side-window type  PMT (e.g. R928)

<3ns

1ns

CFD-2G-D

Head-on type PMT (e.g. R5509)

Typically >3ns

1.5ns

Applications include:

  • Time-resolved fluorescence detection
  • Chemi-luminescence detection
  • Bioluminescence
  • Time-of-flight mass spectrometry
  • Single molecule detection
  • Photon correlation spectroscopy
  • LIDAR

Gain

20dB to 30dB programmable (40dB option available)

Threshold adjustment

-10mV to -200mV

Input connector

SMA type

Output connectors

Lemo00 (NIM, Camac)

NIM output

-0.8V peak at 5ns duration (50-Ohm termination)

TTL output

>2V peak at 5ns duration (50-Ohm termination)

Re-trigger rate50MHz

Indicators

Host, Limit, Count, Power

Power requirement

15V DC

Dimensions

13.5cm x 20cm x 3.9cm

Weight

0.47 kg

Specifications and appearance are subject to change without notice

CFD-2G example data

CFD-2G-A Example data - 34ps (FWHM) prompt with R3809 MCP-PMT and DeltaDiode laser.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

DeltaFlex
DeltaFlex

형광수명측정기

DeltaPro
DeltaPro

형광수명측정기

DeltaTime
DeltaTime

TCSPC Lifetime Kit

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax
FluoroMax

Steady State and Lifetime Benchtop Spectrofluorometer

NanoLED
NanoLED

Pulsed Laser and LED Light Sources

PPD Photon Counting Detector
PPD Photon Counting Detector

Single photons detection with picosecond accuracy

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Ultima
Ultima

Ultra Fast TCSPC Lifetime Fluorometer

Aqualog - Water Treatment Plant Analyzer
Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

DeltaDiode
DeltaDiode

Pulsed Laser and LED Light Sources

DeltaFlex
DeltaFlex

형광수명측정기

DeltaPro
DeltaPro

형광수명측정기

DeltaTime
DeltaTime

TCSPC Lifetime Kit

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

FLIMera
FLIMera

Imaging camera for dynamic FLIM studies at real time video rates

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax
FluoroMax

Steady State and Lifetime Benchtop Spectrofluorometer

NanoLED
NanoLED

Pulsed Laser and LED Light Sources

Nanolog-Spectrofluorometer for Nanomaterials
Nanolog-Spectrofluorometer for Nanomaterials

Steady State and Lifetime Nanotechnology EEM Spectrofluorometer

PPD Photon Counting Detector
PPD Photon Counting Detector

Single photons detection with picosecond accuracy

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Ultima
Ultima

Ultra Fast TCSPC Lifetime Fluorometer

Corporate