FL-1013 Liquid Nitrogen Dewar Assembly

FL-1013 Liquid Nitrogen Dewar Assembly

For phosphorescence or delayed fluorescence measurements, it is sometimes desirable to cool samples to liquid-nitrogen temperature. The FL-1013 LN dewar accessory enables these measurements with Fluorolog and FluoroMax systems.

Segment: Scientific
Manufacturing Company: HORIBA Scientific

The sample is placed in the quartz cell which is then immersed in the liquid-nitrogen-filled dewar. A Teflon cone in the bottom of the dewar keeps the quartz sample-tube centered. The portion of the dewar which is in the light path is constructed of fused silica to preserve the UV measurement capabilities of the instrument. A Teflon cover on the top of the dewar captures any excess liquid nitrogen that bubbles out of the assembly. A pedestal holds the dewar in the sampling module.

Also included is a “stove-pipe” sample cover that allows LN to be added as needed.

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

DeltaFlex
DeltaFlex

형광수명측정기

DeltaPro
DeltaPro

형광수명측정기

DeltaTime
DeltaTime

TCSPC Lifetime Kit

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax
FluoroMax

Steady State and Lifetime Benchtop Spectrofluorometer

NanoLED
NanoLED

Pulsed Laser and LED Light Sources

PPD Photon Counting Detector
PPD Photon Counting Detector

Single photons detection with picosecond accuracy

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Ultima
Ultima

Ultra Fast TCSPC Lifetime Fluorometer

Aqualog - Water Treatment Plant Analyzer
Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

DeltaDiode
DeltaDiode

Pulsed Laser and LED Light Sources

DeltaFlex
DeltaFlex

형광수명측정기

DeltaPro
DeltaPro

형광수명측정기

DeltaTime
DeltaTime

TCSPC Lifetime Kit

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

FLIMera
FLIMera

Imaging camera for dynamic FLIM studies at real time video rates

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax
FluoroMax

Steady State and Lifetime Benchtop Spectrofluorometer

NanoLED
NanoLED

Pulsed Laser and LED Light Sources

Nanolog-Spectrofluorometer for Nanomaterials
Nanolog-Spectrofluorometer for Nanomaterials

Steady State and Lifetime Nanotechnology EEM Spectrofluorometer

PPD Photon Counting Detector
PPD Photon Counting Detector

Single photons detection with picosecond accuracy

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Ultima
Ultima

Ultra Fast TCSPC Lifetime Fluorometer

Corporate