MiniFlow Accessory

Small Volume Circulation System

Minimize sample and dispersant volume requirements with all the convenience of a fully-automated circulation system. This accessory for the Partica LA-960V2 has a measurement range of 0.01~1000 µm and has a measurement time of approximately 60 seconds from filling and measurement to rinsing.

Segment: Scientific
Manufacturing Company: HORIBA, Ltd.
Quick, Accurate Operation

The navigation function documents the automatic measurement procedure.

High Performance without Compromise

The software controls all sequences such as fill, rinse and drain just like the normal flow system. No manual operation is required! Exchange the MiniFlow system with the regular flow cell in seconds, without any tools.

Easy Maintenance

The measurement cell is easily removed for cleaning.

Unique Features:
  • Minimizes sample dispersant volume requirements
  • Permits use of any organic solvent
  • Built-in ultrasonic probe available for dispersing agglomerated materials
  • Auto-fill pump and auto-drain are standard features
  • Normal operation from the PC software
  • LA-960 Method Expert software compatible

 

Potential Applications
  • Limited or precious sample applications.
  • Any sample requiring organic solvent dispersion.
  • Oil dispersions of pigments, polymers and resin products.
  • Sample handling systems to minimize operator exposure.
  • Minimize hazardous solvent use to limit waste disposal.

Measurement Specifications

Measurement range: 0.01~1000 µm
Measurement time: Approximately 60 seconds from filling & measurement to rinsing.
Measurement method: Circulation system with the flow cell.
Sample amount: Approximately 0.2mg~1.0g (Depending on the sample’s particle size and density).
Dispersing liquid volume: 35~55 ml

Circulation System Details

Ultrasonic probe: 40kHz, 7 steps of power control, Titanium alloy.
Centrifugal pump: 15 steps of speed control
Auto-fill pump: Teflon diaphragm pump
Other materials contact in fluids: Tempax glass, SUS316, Titanium alloy (Ultrasonic probe), Teflon, Perfluoro Elastomers

Operational Environment Condition

Temperature: 15~35°C
Relative humidity: 85% or less, no condensation

Power Supply

120V AC+10% or 230V AC+10%, AC 50/60Hz+1%, 120VA

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

nanoPartica SZ-100V2 Series
nanoPartica SZ-100V2 Series

나노입자 분석기

Partica CENTRIFUGE*
Partica CENTRIFUGE*

원심 나노 입자 분석기

Partica LA-960V2
Partica LA-960V2

레이저 산란 입자 크기 분포 분석기

Partica mini LA-350
Partica mini LA-350

레이저 회절 입도 분포 분석기

SZ-100 시리즈
SZ-100 시리즈

나노 입자 분석기

ViewSizer 3000
ViewSizer 3000

멀티 레이저 나노 입자 추적 분석기

Partica LA-960V2
Partica LA-960V2

레이저 산란 입자 크기 분포 분석기

Partica mini LA-350
Partica mini LA-350

레이저 회절 입도 분포 분석기

Corporate