SFA-20 Stopped Flow Device

SFA-20 Stopped Flow Device

The SFA-20/SPEX series of stopped-flow rapid-kinetics accessories offers versatility for spectroscopic monitoring of fast reactions in solution.

Segment: Scientific
Manufacturing Company: HORIBA Scientific

What is it?

  • One of the most frequently used rapid kinetics techniques.
  • Used to study fast kinetics reactions (in the millisecond timescale) between two mixed reactants.
  • Many applications in the chemistry and biochemistry fields.
    • Quenching studies
    • Energy transfers
    • Enzymes kinetics

How does it work?

  • Under pneumatic drive activation, the two small volumes of solutions are driven from high performance syringes through a high efficiency mixer.
  • The resultant mixture passes through a measurement flow cell and into a stopping syringe.
  • Just prior to stopping, a steady state flow is achieved.
  • As the solution fills the stopping syringe, the plunger hits a block, causing the flow to be stopped instantaneously.
  • Using appropriate techniques, the kinetics of the reaction can be measured in the cell.

Features

  • Dead time < 8 ms
  • Observation cell optimized for best performance with SPEX® instruments
  • Integrates into any current SPEX® fluorescence system
  • Multi-mixing ability
  • Flexible thermostat format
  • Sample’s path constructed of chemically inert Kel-F™, silica, Teflon®, and glass
  • Crush-resistant flexible umbilical

Teflon® is a registered trademark of E.I. DuPont de Nemours, Inc.

Dead Time:<8 ms
Dead Volume:700 µL (SFA-20 and SFA-20mx); 350 µL (SFA-20M and SFA-20mxM)
Window Sizes:3 mm wide
Flow cell\'s beam height:15 mm from base of cell to center of window
Min. vol. per determination:100 µL per reactant
Observation path:3 mm for excitation and 3 mm for emission
Observation cell:Silica
Fill-syringe volume:5mL
Windows:3 mm wide x 10 mm high for excitation and emission, specifically designed for FluoroMax® and FluoroLog® instruments
Adjustable stop volume:Available
Mixing ratio:Up to 20:1
Temperature range:5 - 80°C
Piston Drive:Manual drive is standard; Pneumatic control optional. We recommend, however, the SFA-20mx/SPEX and SFA-20mxM/SPEX Umbilical length = 600 mm (SFA-20/SPEX and SFA-20mx/SPEX); 300 mm (SFA-20M/SPEX and SFA-20mxM/SPEX); other lengths on request
Drive syringes:2.5 mL for SFA-20/SPEX; 1 mL for other models High-efficiency T-format mixer: Available for SFA-20/SPEX and SFA-20M/SPEX; 10 µL delay available for SFA-20mx/SPEX and SFA-20mxM/SPEX; longer delays upon request

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

DeltaFlex
DeltaFlex

형광수명측정기

DeltaPro
DeltaPro

형광수명측정기

DeltaTime
DeltaTime

TCSPC Lifetime Kit

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax
FluoroMax

Steady State and Lifetime Benchtop Spectrofluorometer

NanoLED
NanoLED

Pulsed Laser and LED Light Sources

PPD Photon Counting Detector
PPD Photon Counting Detector

Single photons detection with picosecond accuracy

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Ultima
Ultima

Ultra Fast TCSPC Lifetime Fluorometer

Aqualog - Water Treatment Plant Analyzer
Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

DeltaDiode
DeltaDiode

Pulsed Laser and LED Light Sources

DeltaFlex
DeltaFlex

형광수명측정기

DeltaPro
DeltaPro

형광수명측정기

DeltaTime
DeltaTime

TCSPC Lifetime Kit

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

FLIMera
FLIMera

Imaging camera for dynamic FLIM studies at real time video rates

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax
FluoroMax

Steady State and Lifetime Benchtop Spectrofluorometer

NanoLED
NanoLED

Pulsed Laser and LED Light Sources

Nanolog-Spectrofluorometer for Nanomaterials
Nanolog-Spectrofluorometer for Nanomaterials

Steady State and Lifetime Nanotechnology EEM Spectrofluorometer

PPD Photon Counting Detector
PPD Photon Counting Detector

Single photons detection with picosecond accuracy

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Ultima
Ultima

Ultra Fast TCSPC Lifetime Fluorometer

Corporate