ABX Micros 60

ABX Micros 60 HORIBA hematology analyzer video

Hematology Analyzer

Process efficiency in Hematology

  • Impedance technology, photometry
  • Microsampling: Only 10 µL
  • Smart card based memory storage (optional)
  • No compressor (stepper motor technology)

 

*This product may not be available in your country or region at this time. Please contact your HORIBA Medical sales representative or distributor for more information. 

Segment: Medical
Division: Hematology
Manufacturing Company: HORIBA ABX SAS

• Measurement methods: Impedance technology, photometry.

• Liquid valves (without pinching): Reliability and increased precision

• No compressor (stepper motor): Reliability, less maintenance and noise

• 8 or 18 fully automated parameters

• CBC / 3 Part DIFF

• Open or Closed Tube

Technical

Weight

31 lbs

Power supply

90/240 V - 50/60 Hz - 230 VA.

Dimensions

16.5 in x 14 x 12.5 in (HxWxD).

Printer

Dot matrix.

Throughout

60 samples/hour (on open tube)
55 samples/hour (closed tube)

Data management

Automated smart cards used for QC and patient data storage (optional).
RS 232 output.
Mono-directional connection.

Memory

Last result (with curves) or 78 results (optional smart cards based memory)

Screen

2 lines of 40 alphanumerical characters.

Keyboard

Barcode reader (optional).

 

Samples

60 samples/hour (open tube)

Parameters (16+2)

CBC Mode (18 parameters): WBC, RBC, HGB, HCT, MCV,*RDW, MCH, MCHC, PLT, MPV, PCT, *PDW, % and # of LYM, MON and GRA

Graphics

LMG histogram, RBC, PLT histograms

Sample-Volume

CBC mode: 10 µL

Stability

24 hours (CBC)

Operating sample mode

Open tube mode with 4 position tube holder (QC, 125 or 500 µL, 3 or 5 mL)

Identification

Patient I.D., Sequence#

Flags

Pathological flags (WBC, RBC, and PLT) normal limits and counting failure flags

 * RUO (Research Use Only)

Results

Parameters

Precision (cv %)

Linearity

WBC

< 2,5%

0-100 x 10³/mm3

RBC

< 2%

0-8 x 106/mm3

HGB

< 1.5%

0-26 g/dl

HCT

< 2%

0-80%

PLT (whole blood)

< 5%

0-2200 x 10³/mm3

PLT (PLT concentrate)

< 5%

0-4000 x 10³/mm3

 

Blood Controls

Reference

Description

 

2042208

ABX Minotrol 16 - 2L

2 x 2.5 mL vial

2042209

ABX Minotrol 16 - 2N

2 x 2.5 mL vial

2042202

ABX Minotrol 16 - 2H

2 x 2.5 mL vial

Calibrators

Test Reference

Description

 

2032002

ABX Minocal

2 mL vial

N: normal level, H: high level, L: low level
* Recommended by HORIBA Medical

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Product accessories

Accreditation Folder (ISO)
Accreditation Folder (ISO)

Accreditation Support

CellaVision®
CellaVision®

Digital Cell Morphology Systems

Hematovision
Hematovision

Accreditation Support

Quality Control Program (QCP)
Quality Control Program (QCP)

Accreditation Support

RAL SmearBox
RAL SmearBox

Blood Smearing Device

RAL StainBox
RAL StainBox

Blood Slide Stainer

RAL Stainer
RAL Stainer

Blood Slide Stainer

Corporate