OPSA-150

OPSA-150

유기오염물질 모니터

OPSA-150은 HORIBA의 25년 전문 기술을 접목한 독자적인 로터리 셀 길이 변조를 사용한 유기오염물질 모니터입니다.
이 장치는 COD 모니터링 규정 준수를 결정하기 위한 배수 시스템의 유기 오염 물질 모니터링, 급수 취수구의 유기 물질 수준을 측정하기 위한 수질 모니터링 및 프로세스 라인(페놀 미터)의 유기 오염 물질 모니터링으로 사용될 수 있습니다.

*폴마운트, 아웃도어커버, 분석패널이 옵션으로 제공됩니다.

Division: Water Pollution
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Sensor that makes full use of Rotary Cell Length Modulation

(JAPAN Patent No. 4627022, KOREA Patent No. 10-0840034, CHINA Patent No. ZL200610110930.8)

  • Zero drift correction is perfomed in every cycle of measurement. This correction can eliminate the effect of any interference on cells.

  • Cell length modulation provides readings from multiple measurements, making available results from various cell lengths. This allows the single device to make measurements on a large range of concentrations from as low as 0 to 0.1 Abs, up to 0 to 5.0 Abs.



* CompactFlash is a registered trademark or trademark of SanDisc Corporation in the United States and other countries.

 

Easy-to-use Control Panel

Control of the OPSA-150 is operated via the intuitively designed touch panel. An interactive setup screen eliminates any doubts that a user may have while operating the unit. The Converted COD and TURB Display allow readings to be confirmed on site.

Automatic Data Recording up to One Year

Internal data memory provides data strage for one year in case of one measuring value per hour. A CompactFlash® card can be used to allow easy transfer of data to a PC.

 

HORIBA's Proprietary Wiper System

The cell is cleaned continuously by the wiper to eliminate any interference in the measurement light path. Therefore, errors in readings from dirty cells, or differences in results before and after cleaning are not evident.

Sample Failure Switch Input

The sample error alarm provided as an option on the previous OPSA120 is now a standard feature.

Ten Times Increase in Analysis Sensitivity

The mimimum accuracy of analysis ability has been increased to 0.0001 Abs, a ten-fold increase over the previous OPSA-120 unit. Measurements can be made on concentrations as low as 0 to 0.1 Abs.

Product nameOrganic Pollutant Monitor (UV meter)
ModelOPSA-150
Measurement itemUV absorbance, VIS absorbance, COD conversion concentration, TURB (turbidity) conversion concentration
Measurement principleDual optical path, Dual wavelength, rotary cell length modulation method
Measurement wavelengthUltraviolet: 253.7 nm, Visible light: 546.1 nm
Structure of analyzer unitCirculation type
Measurement range
(converted by cell 10mm)
UV absorbance/VIS absorbance
Full scale: 0.1 Abs to 5.0 Abs (setting by 0.1 Abs is possible)
Minimum scale0.0001 Abs (changeable to 0.001 Abs)
RepeatabilityWithin ±2.0% of full scale
(Within ±5.0% of full scale for 2.6 Abs to 5.0 Abs)
LinearityWithin ±2.0% of full scale
(Within ±5.0% of full scale for 2.6 Abs to 5.0 Abs)
StabilityWithin ±2.0%/24 h of full scale
(Within ±4.0%/24 h of full scale for 2.6 Abs to 5.0 Abs)
Response timeT90, within 1 minute (flow rate of approximately 5 L/min)
Cleaning method
(cleaning cycle)
Automatic cleaning by wiper (automatic continuous cleaning)
Display methodLCD display:
320 × 240 monochrome graphics LCD data display with dot backlighting (a touch-panel)
Display content:
UV absorbance, VIS absorbance, UV-VIS absorbance, COD conversion concentration, TURB (turbidity) conversion concentration
Calibration methodSolution calibration using zero solution and span solution (calibration solution in the ampoule)
(one-touch calibration is possible)
Sample water conditionTemperature: 2°C to 40°C (should not be frozen)
Flow rate of sample water: Min. 2 L/min, Max. 20 L/min
* Keep the unit warm (or preserve the heat) to ensure protection against frozen sample water in the cold weather.
Ambient temperature and
humidity
Ambient temperature: 0°C to 40°C, Ambient humidity: 85% or below
Analog outputPoint: 3
Type: arbitrary 3 items from UV absorbance, VIS absorbance, UV-VIS
absorbance, COD conversion concentration, and TURB (turbidity) conversion
concentration (selectable)
Specification: 4 mA to 20 mA DC or 0 mA to 16 mA DC, insulated output
(however, non-insulated among each channel)
Maximum load resistance: 600 Ω
Contact outputPoint: 6
Type: arbitrary 4 items from POWER OFF, MAINTENANCE (standard, fixed allocation)
BATCH ALARM, COD MAX ALARM, TURB MAX ALARM (standard), LIGHT SOURCE MALFUNCTION, NO SAMPLE, CLEANING MOTOR ERROR,
ANALYZER ERROR (selectable)
Content: POWER OFF: when the power OFF occurred.
BATCH ALARM: CLEANING MOTOR ERROR, LIGHT SOURCE
MALFUNCTION, ANALYZER ERROR
MAINTENANCE: at in-maintenance mode and calibration mode, and when maintenance switch is ON.
Specification: contact output without voltage, a contact
Contact rating: 125 V AC/0.3 A, 30 V DC/1 A
(however, for load resistance) each output COM-independent
Contact inputPoint: 2
Type: Float switch input, time adjustment input
Specification: contact input without voltage (open collector can be connected), insulated input
ON resistance: Max. 100 Ω, Open voltage: 5.5 V DC, Short circuit current:
Max. 10 mA
CommunicationInterface: RS-232C compliant
Communication speed: 19200 bps
Data memoryMemorize the data of measurement value of the measurement item in the main body.
Memorized data can be transferred to the CF card.
Memory interval: 1 minute or 1 hour
Memory time: on the hour every hour
Data memory time: interval of 1 minute: approximately 10 days
interval of 1 hour: approximately 1 year
* The latest data is memorized.
Light source/detectorLight source: low pressure mercury-vapor lamp, detector: silicon photo diode
Piping sockets
  • Sample inlet Rp-1/2 female
  • Bypass outlet Rc-1/2 female
  • Overflow outlet (1) Elbow fitting, 13A (nominal)
  • Overflow outlet (2) Elbow fitting, 20A (nominal)
  • Drain outlet Rc-1/2 female
  • Discharge Tube coupling, 50A (nominal)
StructureWeather-proofed for outdoor installation (equivalent to IP54)
Main material of each unitSUS, PVC, PP, CR, SiO2
Power100 V to 230 V AC ±10%, 50/60 Hz
Power consumption100 V to 120 V AC, Max. 45 VA
200 V to 230 V AC, Max. 60 VA
MassControl unit: approximately 5.0 kg
Analyzer unit: approximately 5.6 kg
DimensionControl unit: 240 (W) × 104 (D) × 320 (H) mm
Analyzer unit: 200 (W) × 180 (D) × 403 (H) mm
(Protruding portion are not included.)
Painting colorControl unit: Munsel 5PB 8/1
Conditions for installation
  • Flat and stable places free from strong vibration or shock
  • Places free from dirt or dust, or where no corrosive gases will be generated.
  • At the atmospheric pressure
  • Places not subject to direct sunlight
  • Places well-ventilated
  • Altitude of 2000 m or below

제품 문의

HORIBA제품의 자세한 정보를 원하시면, 아래의 양식에 내용을 입력을 부탁드립니다.

* 는 필수입력항목입니다.

Related products

CODA-500
CODA-500

자동 COD 측정기

CS-620F
CS-620F

광섬유형 고온 인산 농도 모니터

CS-900
CS-900

비접촉 화학물질 농도 모니터

HD-960L
HD-960L

저농도 용존 산소 모니터

HD-960LR
HD-960LR

용존 산소 농도 모니터

HE-480C-GC
HE-480C-GC

카본 센서 전도도계 (저농도형)

HE-960CA
HE-960CA

구연산 모니터

HE-960H-KOH
HE-960H-KOH

KOH 모니터

HE-960H-TM-S
HE-960H-TM-S

고정밀 TMAH 농도 모니터

HE-960HC
HE-960HC

카본 센서 전도도계 (고농도형)

HE-960LC
HE-960LC

카본 센서 전도도계

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

평탄 카본 센서 전도도계

HE-960RW-GC(W)
HE-960RW-GC(W)

2-채널 저항률계

HF-960EM
HF-960EM

인라인 센서 및 자동 범위 전환 농도 모니터

HF-SP-CU
HF-SP-CU

2-채널 고정밀 HF 농도 모니터

HT-110
HT-110

총유기탄소 모니터

HU-200SS
HU-200SS

현장설치형 MLSS Meter (4-Wire Transmission)

HU-200TB-H
HU-200TB-H

현장설치형 탁도계 (4-Wire Transmission, High-sensitivity)

HU-200TB-IM
HU-200TB-IM

공정용 삽입형 SS/탁도 측정기

HU-200TB-W
HU-200TB-W

현장 설치형 탁도계 (4-Wire Transmission, For Wide Range)

HZ-960
HZ-960

용해 오존 모니터

HZ-960HPO-M
HZ-960HPO-M

H2O2 모니터

OPSA-150
OPSA-150

유기오염물질 모니터

SLIA-300
SLIA-300

고감도 실리카 분석기

SLIA-5000
SLIA-5000

실리카 측정기

TPNA-500
TPNA-500

자동 총질소/총인 측정기

TW-100
TW-100

자동 수질 측정장치

TW-150
TW-150

Online Water Quality Monitor (공정 수질 측정 시스템)

U-50 Series
U-50 Series

다항목 수질 측정기

Ultima Expert LT
Ultima Expert LT

Affordable high performance ICP-OES

UP-100
UP-100

마이크로 볼륨 pH 모니터

CS-620F
CS-620F

광섬유형 고온 인산 농도 모니터

CS-900
CS-900

비접촉 화학물질 농도 모니터

HU-200SS
HU-200SS

현장설치형 MLSS Meter (4-Wire Transmission)

HU-200TB-H
HU-200TB-H

현장설치형 탁도계 (4-Wire Transmission, High-sensitivity)

HU-200TB-IM
HU-200TB-IM

공정용 삽입형 SS/탁도 측정기

HU-200TB-W
HU-200TB-W

현장 설치형 탁도계 (4-Wire Transmission, For Wide Range)

HZ-960
HZ-960

용해 오존 모니터

HZ-960HPO-M
HZ-960HPO-M

H2O2 모니터

OPSA-150
OPSA-150

유기오염물질 모니터

TPNA-500
TPNA-500

자동 총질소/총인 측정기

U-50 Series
U-50 Series

다항목 수질 측정기

Corporate